55EG9600 IN-START "Power Off Status" Details (1 of 3)
MODE
POWER_OFF_BY_17VOVP
POWER_OFF_BY_17VUVP
POWER_OFF_BY_1SEC_POWER_OFF
POWER_OFF_BY_20V_DETECT
POWER_OFF_BY_5VMNT
POWER_OFF_BY_ABN
POWER_OFF_BY_ABNORMAL1
POWER_OFF_BY_ACDET
POWER_OFF_BY_AUTO_OFF
POWER_OFF_BY_CH_UPDATE_TIMER
POWER_OFF_BY_CH_UPDATE_TIMER_END
POWER_OFF_BY_CIPLUS_SEARCH_END
POWER_OFF_BY_COMP_END
POWER_OFF_BY_COMP_FAIL
POWER_OFF_BY_COOLING
POWER_OFF_BY_CPU_ABNORMAL
POWER_OFF_BY_CPUCMD
POWER_OFF_BY_DATA_FLASH
POWER_OFF_BY_EDID_WRITE
POWER_OFF_BY_EWBS
POWER_OFF_BY_FAN_CONTROL
POWER_OFF_BY_FAN_CTRL_ERROR
POWER_OFF_BY_HDMI_CEC
POWER_OFF_BY_HOMING_COMPLETE
POWER_OFF_BY_INSTOP_KEY
POWER_OFF_BY_INV_ERROR
POWER_OFF_BY_KEYTIMEOUT
POWER_OFF_BY_MAIN_WDT
POWER_OFF_BY_Micom_RESET
POWER_OFF_BY_MICOM_UPDATE
November 2018
Contents
17 V Over Voltage Protect (PDP Only)
17 V Under Voltage Protect (PDP Only)
CONDITION: When power button is repeatedly pressed on, CPU does not complete the
boot cycle
RESULT : Micom force to trigger TV power off.
CONDITION : when OLED detects a drop in Drain (depending on panel design) voltage
level (20V).
Power off by not detecting 5V monitoring
RESULT : Micom triggers TV power off
CONDITION : During AC on or DC on, stabilization check routine, the voltage level is
incorrect.
Power off by abnormal status
RESULT : Micom triggers TV power off
CONDITION : when Display port model (Nano LED, LZ9600) does not detect port cable.
Power off by abnormal status
Power off by loss of AC-Detect
RESULT : Micom triggers TV power off
CONDITION : Power detect port drops to low while power in "on" status.
Power off by auto off function
1. When it lasts for 15 minutes that no signal and no remote key input.
2. When screen mute status lasts for 2 hours.
start : get channel update in warm standby (for Italy model.)
end : get channel update in warm standby (for Italy model.)
CI+ search complete. (Log)
RESULT: Power off
CONDITION: OLED Compensation (Threshold voltage degradation) completes, (OLED
up to webOS 2.0)
A failure has been reported to the Micom from the OLED display or Compensation was
interrupted. , (OLED up to webOS 2.0)
Power off for cool down the OLED t-con. (OLED) webOS 3.5 or later
Power off by CPU Abnormal status
Power off by CPU Command
When Micom EEPROM is initialized, log for reference of EEPROM initialization error.
Power off by EDID write done.
Power off by EWBS function.
Power off by fan control
power off by fan control error (for OLED/STB model)
Power off by HDMI CEC command
Power off by Cable Card Update (USA only)
Power off by Instop Key
Power off by LCD module inverter error (OLED)
Power off when TV is not turned off during a certain time
RESULT : Micom force to trigger TV power off.
CONDITION : When pressing power key while power on status, CPU does not response
within 10 seconds or send delay command.
Main Micom Reset
Power off by micom update.
Page 04
55EG9600 (2015) In-Start Menu
Action
Y, Z, SMPS
SMPS
Main
SMPS, Panel
Y, Z, Cntl, Main, SMPS
Main , IR, T-Con
Main, IR, Wifi
SMPS, Main
None
None
None
Main
None
SW, Main, Panel
None
Main, IR, Wifi
Main, IR, Wifi
Main
None
Main
Fan / Main
Main, Fan
None
N/A
None
SW, Main, Panel
None
Main
None
None
LG