ROMAN Colossus FC13 Instruction Manual

Advertisement

Quick Links

Colossus
Instruction Manual
Consumer Guarantee -
which is enclosed with this product. Failure to validate the Guarantee will mean only the 1 Year Statutory Guarantee will apply.
IMPORTANT: IF YOU ARE FITTING THIS PRODUCT WITH INTEGRATED WATER DELIVERY, THE VALVE MUST BE INSTALLED
BEFORE TILING THE SHOWERING AREA AND BEFORE THE INSTALLATION OF THIS PRODUCT.
FC:CQB
4/5/10
12:13
Page 1
1. Check you have the correct enclosure and tray. Please look at the labels on the side of the product packaging.
2. Check all the product components are in the box and the fixing kits are complete. Please check this with the component check list overleaf.
3. Un Pack your product and handle it with care.
4. Please check the product for defects or damage. Once the installation has commenced we cannot accept responsibility for any defects or
damage to the products.
5. Please take the time to read these instructions prior to installing your product.
6. Before you commence any drilling check there are no hidden electrical cables and/or water pipes in the walls.
7. No attempt should be made to re-work the toughened safety glass.
8. The installation should be performed by two persons.
9. It is strongly recommended the walls the product is going to be installed on are vertical. However the wall profiles have 25mm of adjustment
to help compensate for some deviation.
10. It is strongly recommended the product is fitted on tiled surface or similar waterproof surface.
11. It is strongly recommended the walls are tiled and grouted after the installation of the tray and before the installation of the product. This will
provide maximum adjustment and help when sealing the product.
12. If the walls and/or the tray are not level you will not achieve maximum adjustment of the product.
13. Pictures used are for illustration purposes only, product designs may alter slightly as a result of continuing product development.
14. We do not stipulate where the European Standard Kite Mark should be positioned on the glass panels
when being factory assembled.
Roman's toughened glass is completely safe for use in our shower enclosures and bath screens; providing our products are installed
according to our guidelines.
It is important to note, that the glass must not be mounted or 'pinched' in such a way that would cause a stress point to develop in the
glass. In addition, it must not be subjected to any sharp impact or severe temperature fluctuation which may also cause a stress point to
develop in the glass.
Roman's toughened glass is physically and thermally significantly stronger than standard glass. During our toughening process the
stresses contained within any glass are balanced so if in the unlikely situation any of the above occurs and the glass breaks, the glass will
shatter safely into small thumbnail sized blunt fragments.

IMPORTANT PRE-INSTALLATION CHECKS

Please make sure the purchaser/end user completes and returns the Guarantee card

IMPORTANT INFORMATION

FC
FC/May 10

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Colossus FC13 and is the answer not in the manual?

Questions and answers

Summary of Contents for ROMAN Colossus FC13

  • Page 1 14. We do not stipulate where the European Standard Kite Mark should be positioned on the glass panels when being factory assembled. • Roman’s toughened glass is completely safe for use in our shower enclosures and bath screens; providing our products are installed according to our guidelines. •...
  • Page 2 Component Check List: Supplied Equipment Check List: Not Supplied Description Quantity Description FC13 FCG13 Mains or battery drill. Curved Panel 6mm masonry drill bit. Side Panel Bathroom sealant gun. Wall Profiles Bathroom sealant tube. IMPORTANT PRE-INSTALLATION CHECKS Wall Profile Trims Pozi Screw driver.
  • Page 3 Step 2 - Fixing the Wall Profiles. FC:CQB 4/5/10 12:13 Page 3 Fix Wall Profile: 1 1. Position the wall profile using the guide on the tray. The lip of the profiles face towards the inside of the enclosure (look at point 2 above).
  • Page 4 Step 3 - Fix the Curved Panel (and end panel if applicable) (Pease ensure the transport bands are removed with care from the glass panels in this and the following steps.) FC:CQB 4/5/10 12:13 Page 4 1. Remove the black transit caps from all the glass panels. 2.
  • Page 5 Step 4 - Assemble the Brace Bar. FC:CQB 4/5/10 12:13 Page 5 1. Disassemble the panel side location cup, and screw the brass insert into the profile on top the curved glass panel, then re- assemble the cup onto the brass insert. Don't tighten the allen key yet. 2.
  • Page 6 2. Place all the cover caps on the profiles. (R and L on the inside of the caps indicate the handing of the caps looking from the outside of the enclosure) 3. Stick on the Roman Branding Badge. 4. Seal vertically the full length of the wall profiles/wall profile trims where they meet the tiles on the inside of the enclosure, using bathroom sealant.
  • Page 7 Spare Parts: If you need to replace any damaged parts please see illustration below for parts list then call Customer Services on 01325 328034. FC:CQB 4/5/10 12:13 Page 7 Item No. Part Number Colour Description Length (mm) ROGWPS Silver Wall Profile 1900 ROG02S Silver...
  • Page 8 Straight to floor guidance: Locating the wall profiles and using the panel location pin (steps 2 and 3). The measurements left need to be used to locate the wall profiles (step 2). The location pin measurements left need to be used to locate the glass panel (step 3). 1.

This manual is also suitable for:

Colossus fcg13

Table of Contents