Software Configuration Settings Continued
Option 1*
Option 3*
Option 4*
*Note: Options 3-4: Y = On/Off w/ no timeout (toggle) mode; P = Pulse (momentary) mode
Cleanup Cycles**
**Sets default for user preferences - only applies when persistent memory is reset (A12 On) during power-up.
Cleanup Cycles as User Preference
Ozone Operation
Ozone Suppression
Ozone Icon
Ozone Location
n
Y
P
n = Disabled; Y/P = Enabled on J17;
n
Y
P
n = Disabled; Y/P = Enabled on pin 1 of X-P332 board;
n
Y
P
n = Disabled; Y/P = Enabled on pin 2 of X-P332 board;
0
1
2
3
4
0 = Disabled; 1-4 = Number of hours
n
Y
n = Only in Configuration Settings;
Y = Over-rideable by User via User Preferences
A
F
A= Operates with Heater Pump (Pump 1 Low or Circ Pump);
F = Operates in Filter and Cleanup Cycles only;
n
Y
n = No Suppress; Y = 1-hour suppress on button press;
n
Y
n = O
Icon on Panels Disabled; Y = O
3
o
b
o = Ozone on J29 (Shares relay with Circ Pump in Circ Mode.)
b = Ozone on J17 (Neither a 1-Spd Blower or 1-Spd Pump 2 can be used.)
Page 11
= 2 DIP Switch
= 2 DIP Switch
= 2 DIP Switch
= 1 DIP Switch
= 1 DIP Switch
Icon on Panels Enabled
3
EL1500 - 40916_01_C