Download Print this page
Dometic Breathe Easy Owner's Manual

Dometic Breathe Easy Owner's Manual

Portable air purifier

Advertisement

Quick Links

TROUBLESHOOTING (CONTI) Fan is
running, but no blue glow.
1.
UV bulb is not seated correctly in the socket (see "Replacing the UV Bulb").
2.
UV bulb needs to be replaced (see "Replacing the UV Bulb").
3.
Bulb ballast is inoperative.
Output seems ineffective.
Make sure unit is in an enclosed area.
1.
2.
Make sure unit is in an area no greater than 500 sq. ft. (46 sq. m.).
3.
Make sure unit is not directly in the supply-air or return-air streams of the air
conditioning system.
Output seems low.
1.
Remove any obstructions at the unit's input and output vents.
2.
Clean the removable nano-mesh divider (see "Maintenance").
3.
If unit is in a very smoky or dusty area, clean the UV bulb (see "Maintenance").
4.
Is it time for a new bulb? The UV bulb should be replaced each year (see
"Maintenance").
REPLACEMENT PARTS
Replacement parts can be ordered from any Dometic dealer. To find a dealer near you,
go to: www.dometicusa.com
PART NUMBER
REPLACEMENT PART DESCRIPTION
4210804
UV Bulb 5", Photocatalytic Nano-Mesh Divider, Replacement
Due-Date Sticker (kit)
2011029
Fan, Axial 2" 12V DC 13 CFM
4210816
12V Power Cable
4210814
100-240V, 50-60 Hz Power Adapter
WARRANTY
The portable Dometic Breathe Easy Air Purifier is covered by a limited warranty against
defective material for 90 days from date of purchase. This warranty covers electronic
parts only and does not include the UV bulb. The original product sales receipt is
required as proof of purchase.
This warranty does not apply if a unit has been dropped, damaged, or submerged in
water.
To file a warranty claim, contact a Dometic dealer. To find a dealer near you, gc
www.dometicusa.com
mD Dometic
L-2715 Rev 20111216
mD D01netic
Portable
Breathe Easy Air Purifier
Owner's Guide
How
IT WORKS
The Dometic Breathe Easy Air Purifier uses innovative Photocatalytic Nano-Mesh
technology with ultraviolet (UV) light to improve air quality.
Airborne pollutants are molecularly transformed into nontoxic elements when they contact
the Photocatalytic Nano-Mesh surface. The unit uses a specific frequency of UV light that
enables maximum effectiveness yet produces no harmful ozone.
The density and quantity of pollutants present affect how rapidly the air will be cleaned. As
air re-circulates and makes multiple passes through the system you will notice continuously
improving purification levels.
NOTE: The air purifier does not fix the source of ongoing odor problems. For example, a
leak that caused mold must be repaired and the mold must be removed.
SAFETY PRECAUTIONS
WARNING
Do not use outdoors.
Do not block air flow to unit. This may cause the fan to burn out.
Keep the cord away from heated surfaces.
Never open the cover without unplugging the power cord.
Never operate this unit if it has a damaged cord or plug.
If the unit falls into water, unplug it immediately. Do not reach into the water.
Never operate this unit if it has been damaged or submerged in water.
Do not place in an area where uncured siliconized sealers are being used, as
the vapors will inhibit the unit's photocatalytic capability.
Lh.
DANGER
Never look at a lit ultraviolet (UV) bulb.
This equipment is not ignition protected per CFR 183.410 and may not be
installed in areas that may be exposed to flammable gas.
SYSTEM SETUP
Selecting the Location
This unit is designed for use in an enclosed space up to 500 sq. ft. (46 sq. m.).
f
to:
Select an indoor location where air flow will not be blocked.
Do not install directly in the supply-air or return-air streams of the air conditioning
\.
system.
Do not install in areas thafo,ay be exposed to flammable gas.

Advertisement

loading

Summary of Contents for Dometic Breathe Easy

  • Page 1 This unit is designed for use in an enclosed space up to 500 sq. ft. (46 sq. m.). To file a warranty claim, contact a Dometic dealer. To find a dealer near you, gc Select an indoor location where air flow will not be blocked.
  • Page 2 Power Replace with a new Dometic UV bulb (model 4210804). Use of any other bulb will The unit includes adapters to operate on 12V/500mA DC power or 115V/60Hz/300mA, void the warranty. Insert the bulb prongs firmly into the socket. Cover old due- 220V/50Hz/200mA, or 230V/60Hz/275mA AC power.

This manual is also suitable for: