This adapter fits directly onto the Noritz VT4‐TS‐(5, 8, 14, 27) Vent Termination for installations 
on N‐0841MC‐DV model water heaters.  The following parts are supplied in the adapter kit.  
Check for any missing items before starting the installation.  For detailed information regarding 
the installation of the VT4‐TS Vent Termination, please refer to the Installation Manual. 
 
Included Parts 
 
Vent Adapter 
4 x 16 Rounded Screw 
Wall Anchor 
Extension Screw 
 
 
 
 
 
TA‐IM‐1 
Rev. 12/08 
Installation Guide
VT4‐TS‐ADAPT (for N‐0841MC‐DV only)
Parts 
Wall Spacer 
Shape 
 
 
 
 
 
 
 
 
Quantity 

Advertisement

loading

Summary of Contents for Noritz VT4-TS-ADAPT

  • Page 1             Installation Guide   VT4‐TS‐ADAPT (for N‐0841MC‐DV only)       This adapter fits directly onto the Noritz VT4‐TS‐(5, 8, 14, 27) Vent Termination for installations  on N‐0841MC‐DV model water heaters.  The following parts are supplied in the adapter kit.   Check for any missing items before starting the installation.  For detailed information regarding  the installation of the VT4‐TS Vent Termination, please refer to the Installation Manual.    Included Parts    Parts  Shape  Quantity    Wall Spacer  1      1  Vent Adapter      4  4 x 16 Rounded Screw      4  Wall Anchor    Extension Screw  4 ...
  • Page 2 NOTE:  The use of this part will change the range of wall thickness that the vent termination can pass  through.  Please review the chart below to verify the changes before proceeding with the installation.    Model Name  Wall Thickness  VT‐4‐TS‐5  50mm(2") to 90mm(3.5")  VT‐4‐TS‐8  90mm(3.5") to 170mm(6.7")  VT‐4‐TS‐14  170mm(6.7") to 330mm(13")  VT‐4‐TS‐27  330mm(13") to 650mm(25.6")    Installation Procedures    1) Replace the original vent termination adapter piece with the new fitting that was provided with the  Vent Termination Adapter Kit by replacing Part B with Part A.    NOTE:  Use caution when inserting the new adapter to the termination.  The o‐ring on the fitting  might get damaged if excessive force is used.        2 ...
  • Page 3 2)   Drill 4 holes for inserting the wall anchors into the wall.  Once anchors are in place, use the 4 x 16  Rounded Screws provided with the Vent Termination Kit to secure the sleeve to the wall.    NOTE:  Do not over tighten the screws to the wall as it may cause the sleeve to become deformed.  If the  part becomes bent or deformed, please loosen the screws so that the sleeve sits flat against the wall.      3) Install the extension screws onto the attachments provided on the sleeve as shown below.  Make  sure that these screws are securely fastened.      3 ...
  • Page 4 4) Begin the installation of the wall spacer to the sleeve by drilling 4 holes for inserting wall anchors as  shown below.  Proceed in using the 4 x 16 Rounded Screws provided with the Vent Termination  Adapter Kit to secure the part to the wall.       5) Complete the installation by inserting the VT4‐TS Vent Termination into the sleeve and attaching it to  the four extension screws on the wall spacer.  If the termination is obstructed, gently insert it while  shifting it back and forth until it is properly in place.  Fasten the four wing nuts to the extension  screws to secure the termination to the wall spacer. 6) For procedures on properly sealing the fittings on the Vent Termination to the intake and exhaust  ports on the water heater, please refer to the VT4‐TS Installation Manual.  4 ...