Page 1
Gaius DUO , installation instructions. 17788 electrical high adjusting, floor drain. 6219-Z 1pc L1500mm 17788 2pcs 330001 330003 20104 20108 20209 20210 20114 20127 20118 20128 4pcs 17788 Save this installation instruction for after use. Säästä tämä asennusohje myöhempää käyttöä varten.
Page 2
Gaius DUO Gaius DUO Attachment points, 8 pcs Water and electric 17788 17788 Reinforce 36mm or more plywood or 45mm or more solid wood. 90 degrees down G1/2” Cut-off valve C holder...
Page 3
Gaius DUO Gaius DUO with Bide Elegant with Bide Elegant with junction box with 2 part wall plug 17788 17788 Mentioned products does not belong in the package. Water tank hose G1/2”, G1/2” L1500mm straight 90 degrees down G1/2” Cut-off valve...
Page 4
Structure The product has undergone static load testing at 500 kg. The size of the wall mounting fixtures is 700x1110 mm. The fixtures must be affixed to solid structures. The fixtures must be mounted in accordance with the measurements specified in the diagram. Electrics The electrical junction box must be positioned to the right of the mid-line, as shown in the draw- ing.
Notice! General instructions: Use motor or crank up and down to help installation. If frame don´t go down by motor, press moving frame down by hand. Connect electricity: Must not exeed 50mm from the wall! Wrap cable L470mm +box connection lenght Authorised personnel only!
Page 6
Water tank hose/ Vesitankille G1/2”, G1/2” L1500mm straight wc-bowl only! 90 degrees/ 90 kulma suora Gaius DUO To the wall G?/ Seinään G? LVI nr. 6522232 G1/2” Female out/Naaras ulos, Cut-off valve/ Sululla Junction box/ Kytkentärasia 230V AC IP44-IP65 T-connect/ T-liitin (Size/Koko 88x88x44) G1/2”, G1/2”, G1/2”...
Page 7
Testing up & down Mind the water pipes and cables 1. Disconnect hand control 2. Choose side to install hand control 3. Pop-up three pieces from cover A 4. Install plug on cover A Add Lock ring inside(1a.)
Page 11
Do not try to unclog any blockage via the toilet bowl as this may damage the flexible pipe. Always perform unclogging by moving the implement in the direction of the building’s drain pipes. In a case of checking or clogging: 1.
Need help?
Do you have a question about the DUO 17788 and is the answer not in the manual?