PL312F
Waterproof Line Array Speaker System
Specification
System:
MF/HF Compression Driver :
LF Driver:
Frequency Response(-3dB):
Sensitivity(1W@1m):
Max.SPL(1m):
Power:
Dispersion:
Rated Impedance:
DC Impedance:
Recommended Crossover Point:
Cabinet:
Installation:
Transportation:
Finish:
Connectors:
Cabinet dimension:
Package dimension:
Net Weight:
Gross Weight:
Optional Accessory:
6
Two-Way Dual 12" Waterproof Line
Array Speaker System
Dual 3" Neodymium compression driver
Dual 12" Neodymium inner magnet woofer
1
LF:55Hz-600Hz
MHF:400Hz-18kHz
2
LF:96dB
MHF:102dB
4
3
LF:123dB/129dB(PEAK)
MHF:120dB/126dB(PEAK)
LF: 600W
MHF: 70W Rated power(RMS)
LF: 1200W
MHF: 140W Long-term max power
LF: 2400W
MHF: 280W Short-term max power
°
Horizontal 100 ,Vertical 0 ×10 Adjustable。
LF:8 Ohms
MHF:16 Ohms
LF:8 Ohms
MHF:16 Ohms
400Hz
15mm Imported birch plywood
Specified frame with 3/4" shackle
2 x Iron handles
Weather resistant polyurethane finish,
black power coating for grille
NL4×2 @ LF:1+ 2-
MHF: 3+ 4-
810×475×354mm(31.9×18.7×13.9in)
605×470×955mm(23.8×18.5×37.6in)
48.0kg(105.6 lb)
52.0kg(114.4 lb)
Flying frame(131.98.0034.00066)
Speaker Testing Method
1. Frequency response
Use Pink noise to test the speaker in the anechoic room, adjust
the level to make the speaker work at its rated impedance and
the power output is 1W, then test the frequency response 1m
away from the speaker.
2. Sensitivity
Use full range Pink noise which was modified by EQ curve to
test the speaker in the anechoic room, enlarge the signal to
make the speaker work at its rated impedance and the power
output is 1W, then test the sensitivity 1m away from the speaker.
° °
3. MAX.SPL
Use full range Pink noise which was modified by EQ curve to
test the speaker in the anechoic room, enlarge the signal to
make the speaker work at its instant power output level, then
test the SPL 1m away from the speaker.
4. Rated Power
Use the pink noise according to IEC#268-5 to test the speaker,
enlarge the signal for continuous 100hours, the rated Power is
the power when the speaker will not incur hot damage or
mechanics damage.