5.5. Control panel

5.5.1. Control panel ARG 180, ARG 200 Plus, ARG 220 Plus, ARG 230 Standard

Basic functions
Before starting the band drive make always sure that the band is NOT in contact with the
workpiece.
TOTAL STOP
BAND SAW START - STOP
START
STOP
SPEED SWITCH
Cutting speeds can be changed by switch placed on the electrical box on the saw engine.
1
2
1 - 40 m/min
2 - 80 m/min
Emergency stop of the main engine and coolant pump. The machine
restart may be done only after manual unblock of the total stop button
(BY PULL). CAUTION : DANGER OF INJURY - after switching the button
the arm (with the band) stills moving down.
Green button - starts the main engine and the coolant pump.
Red button - stops the main engine and coolant pump. When starting the band drive the
saw arm must be raised above the switching level of the down position end switch
otherwise the band drive will NOT be started. CAUTION : DANGER OF INJURY - after
switching the button the arm (with the band) stills moving down.
Saw band STOP
red button
Speeds switch
CAUTION : Speeds may be changed only when the engine
is stopped (saw band is not running)
Saw band START
green button