Overview
Unison Echo Keyswitch Station enables security for
stations within a space by preventing unwanted control-
activation from all stations within the space while the
keyed lockout is enabled.
The Keyswitch Station is designed for use with any
EchoConnect-enabled system including Echo Zone
Controllers, Echo Relay Panels, Sensor3 and Unison DRd
with Echo architectural control processor.
For use with ETC dimming and relay products.
Prepare for Installation
Keyswitch Stations ship with station electronics, faceplate,
termination kit, (2) keys, and installation hardware.
The station installs into an industry standard single-gang back box (RACO 690
or equivalent - provided by others) or an optional surface mount back box (part
number 7081A2004-1) sold separately and available from ETC.
Environmental
For indoor installation only - 0-50° C, 5-95 % non-condensing humidity.
Installation
Installation should follow all local codes and standard electrical practices. The
back box should be installed level and square for best results. Ensure that the
back box is clean and free of obstructions.
Note:
725 and local jurisdiction requirements.
NEC Class 2 product to be wired in accordance to NEC Article
Corporate Headquarters
Serv ic e (Americ as)
n
L ondon, UK
Tel +44 (0)20 8896 1000
n
Rome, IT
Tel +39 (06) 32 111 683
n
Holz kirc hen, DE
Tel +49 (80 24) 47 00-0
n
Hong Kong
Tel +852 2799 1220
n
© 2018 Electronic Theatre Controls, Inc.
W eb:
etcconnect.com
ETC intends this document to be provided in its entirety.
7140M2120
Rev B
n
n
Middleton, Wisconsin, USA
n
service@etcconnect.com
Service: (UK)
n
Service: (UK)
n
Service: (DE)
n
Service: (Asia)
service@etcasia.com
n
Trademark and patent
n
Product information and specifications subject to change.
n
Released 2018-11
Tel +608 831 4116
n
service@etceurope.com
service@etceurope.com
techserv-hoki@etcconnect.com
info: etcconnect.com/IP

Advertisement

loading

Summary of Contents for ETC Echo Keyswitch Station

  • Page 1 Tel +852 2799 1220 Service: (Asia) service@etcasia.com © 2018 Electronic Theatre Controls, Inc. Trademark and patent info: etcconnect.com/IP W eb: etcconnect.com Product information and specifications subject to change. ETC intends this document to be provided in its entirety. 7140M2120 Rev B Released 2018-11...
  • Page 2 Keyswitch Station for custom configuration using EchoAccess, set DIP switch 2 On. Reference the mobile app integrated help system for information to configure custom actions available to the Keyswitch Station. Echo Keyswitch Station Page 2 of 4 Electronic Theatre Controls, Inc.
  • Page 3 Belden 8471 wire and the lead from the power pigtail into the terminals then close the levers. Install the two pin connector from the power pigtail to the mating receptacle on the station electronics. Echo Keyswitch Station Page 3 of 4 Electronic Theatre Controls, Inc.
  • Page 4 Turn the provided key to perform the configured event. Space lockout toggle is the default action. Turn the key again to toggle the event off. Reference Switches on page 2 for information to configure custom events. Echo Keyswitch Station Page 4 of 4 Electronic Theatre Controls, Inc.