Precautions for Installation ....... 14 Y ou should be careful where CAUTION is marked to carry out the work. Failure Check ............14 Y ou should be aware of where NOTICE is marked to carry out the work. Maintenance ............14 HITROL CO., LTD.
■ Solid structure and long service life Characteristic ■ Applicable to high temperature and pressure vessels ■ Current operation state display ■ Customizable with special material (Alloy) ■ Explosion proof version (HM-90-Ex, HM-90H-Ex) ■ ASME B31.1, ASME B31.3 (if chamber design is required) HITROL CO., LTD.
Ex-Proof (Ex d IIC T4, IP65) Switch Type Snap Switch Process Connection 80A JIS 10K RF (Std.) Displacer SUS 304 / SUS 316L Material Chamber C.S / SUS 304 / SUS316L / Others Cable Entry AL; PF 3/4”(F) (Std.) HITROL CO., LTD.
Cooling Cooling Wetted parts Flange Flange Flange Spring holder Spring holder Spring holder Extension Extension Extension spring spring spring Wire Guide pipe Chain Wire Chamber Displacer Displacer Displacer Process Conn. flange <Standard> <Protection Tube> <Side to Side> HITROL CO., LTD.
The dimensions on the following pages are indicated in [mm]. Technical Process ~120˚C ~200˚C ~350˚C / ~500˚C ~500˚C (Opt.) Specifications Temp. C.S + Aluminum Housing (S/W 1ea) C.S + Aluminum Housing (S/W 2~3ea) C.S + Aluminum Housing (S/W 4ea) Some tolerances may occur with actual products. HITROL CO., LTD.
Page 7
HM-30, 90 Series Process ~120˚C ~200˚C ~350˚C / ~500˚C ~500˚C (Opt.) Temp. Aluminum Housing (S/W 1ea) Aluminum Housing (S/W 2~3ea) Aluminum Housing (S/W 4ea) Some tolerances may occur with actual products. HITROL CO., LTD.
HM-30, 90 Series Ex-Proof Version Process ~120˚C ~200˚C ~300˚C ~350˚C Temp. Aluminum Housing (S/W 1ea) Aluminum Housing (S/W 2~3ea) Aluminum Housing (S/W 4ea) Some tolerances may occur with actual products. HITROL CO., LTD.
Switch Specifications by Process Temperature Std. Type Opt. Type Process Temp. Contact Rating AC 250V, 15A ~ 200˚C DC 125V, 0.5A AC 250V, 5A ~ 350˚C DC 125V, 0.5A Std. Type Opt. Type Process Temp. Contact Rating HITROL CO., LTD.
(Epoxy Coated) housing is optional. SPDT Wiring ■ Common (COM) Internal circuit Normal Open (N.O) Normal Close (N.C) DPDT Wiring ■ Common (COM) Common (COM) Normal Open (N.O) Normal Open (N.O) Normal Close (N.C) Normal Close (N.C) HITROL CO., LTD.
120˚C, use a high C, use a high-temperature product (HM t (HM-90H, HM-90H-Ex), and insulate the main unit and connection as Ex), and insulate the main unit and connection as shown below. shown below. HITROL CO., LTD.
- Continuous process operation may be hindered by failure of switch block, so prepare a spare switch block. - Remove the product from the vessel and check and reset the contact of level switch using a liquid (ex. Water) on the process connection. HITROL CO., LTD.
■ Use the cable gland connection or metal pipe line lead-in on the wire inlet, and use a product External with equivalent Ex-proof certificate to connect it with the external line lead-in method. ■ For non-use external wire inlet, use a closed plug that passes safety certificate above equivalent Wire performance with the product. (Ex-proof) HITROL CO., LTD.
■ An Ex-proof product is a pressure-resistant and Ex-proof type, so never open the cover during operation. HITROL CO., LTD. ■ Ex-proof products are designed according to Article 34 of the Industrial Safety and Health Act and Article 58.4 of the Enforcement Rules of the same Act.
You can request A/S at our website or by contacting our headquarters. ■ Headquarters ․ Factory ․ Laboratory Contact Number ADRESS: HITROL CO., LTD 141, Palhakgol-gil, Jori-eup, Paju-si, Gyeonggi-do, Korea T E L : 031-950-9700 (Headquarters & A/S) F A X : 031-943-5600 (Headquarters & A/S)
Need help?
Do you have a question about the HM-30 Series and is the answer not in the manual?
Questions and answers