Teletek electronics TTE Combo Manual
Teletek electronics TTE Combo Manual

Teletek electronics TTE Combo Manual

Lan communication module
Hide thumbs Also See for TTE Combo:

Advertisement

Quick Links

TTE Combo
LAN Communication Module
• Installation and Programming Manual
• Operation Instruction
• User Guide
Attention:
This manual contains information on limitations regarding product use and
function and information on the limitations as to liability of the manufacturer.
The entire manual should be carefully read.
The information in this manual is a subject to change without notice!
Rev. 4.1.x
Release 01/2020

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TTE Combo and is the answer not in the manual?

Questions and answers

Summary of Contents for Teletek electronics TTE Combo

  • Page 1 TTE Combo LAN Communication Module • Installation and Programming Manual • Operation Instruction • User Guide Attention: This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. The entire manual should be carefully read.
  • Page 2: Table Of Contents

    TTE Combo Communication Module – Installation and Programming Manual Table of contents 1. INTRODUCTION ............................4 1.1 General Information ........................4 1.1.1 Functional Features ........................ 5 1.1.2 Technical Specifications......................5 1.1.3 Operation Block Diagrams ...................... 6 Operation with a Burglary Alarm Control panel ................6 Operation as Stand-Alone Device....................
  • Page 3 TTE Combo Communication Module – Installation and Programming Manual DOCUMENTATION FEEDBACK If you have any comments or suggestions on our products’ manuals or installation instructions you can email us on: info@teletek-electronics.bg Your feedback on product documentation will help us to improve the contents of our manuals and stickers and keep them up-to-date.
  • Page 4: Introduction

    When the control panel is additionally equipped with a digital communicator, the standard PSTN telephone line can also be used for backup channel for transmitting of events, as the TTE Combo is connected directly to the digital communicator terminals of the panel. The hardware connection with the panel is monitored and in case of fault or trouble with the line the module will report to the monitoring station.
  • Page 5: Functional Features

    • Dimensions (PCB): ............73x108mm Important note: The purpose of this manual is to give directions for programming the TTE Combo module and its operation with AJAX SP Pro server. You can refer to the installation manual of the module (applied into the packing box) for details about its elements and PCB hardware.
  • Page 6: Operation Block Diagrams

    Teletek Electronics JSC. After registration the User can review the status and to control (switch ON/OFF) the outputs of TTE Combo attached to his account. 8. Mobile TTE. This is a smartphone application for management and control of panels and communication modules produced by Teletek Electronics JSC, which are attached to a User account at AJAX WEB.
  • Page 7: Operation As Stand-Alone Device

    (at least 100MB data traffic per month). - In case the TTE Combo is going to be used as a stand-alone device, equip it with a suitable external power supply unit providing 9-30VDC.
  • Page 8: Hardware Installation

    2.1 Connection to Burglary Alarm Control Panel TTE Combo is mounted into the panel’s installation box. The module can be powered on directly from the +/- AUX outputs (required 9-30VDC) of the control panel as observing the polarity; or from an external power supply unit.
  • Page 9: Basic Installation Steps

    7. Connect the phone device to A1 and B1 terminals of the control panel; in case the phone device is not used – terminate the A1 and B1 terminals with 220k resistor. 8. Connect t a TAMPER switch (or TAMPER zone) to IN1 terminals of TTE Combo. 9. Turn on the main and backup power supply of the panel.
  • Page 10: Tte Combo Module Led Indication

    TTE Combo Communication Module – Installation and Programming Manual 2.4 TTE Combo Module LED Indication The LED indication of TTE Combo communication module has the following meaning during operation. 1. PSTN - LED for presence of PSTN telephone line. 2. RSSI – 3 LEDs for the signal strength of the available GSM/GPRS network.
  • Page 11: Restore To Factory Settings

    TTE Combo Communication Module – Installation and Programming Manual 2.5 Restore to Factory Settings This function is for restoring of the default parameters of the module set by the manufacturer. Reset Jumper Terminals The Reset Jumper is situated on the left side of the SIM card holder. To perform restoring of the factory settings: 1.
  • Page 12: Programming With Proste

    Run the ProsTE software and choose in sequence using the right mouse button: System – Add – TTE Combo. The TTE Combo menus are loaded at the left side as a tree structure. Select the module and using the right mouse button again choose in sequence: TTE Combo – Read.
  • Page 13: General Settings Menu

    3.2 General Settings Menu Click on the “+” icon in front of TTE Combo module to expand the programming menus. Select General Settings menu. The possible settings are displayed on the right side on the screen: Important Note.
  • Page 14 “Ademco CID Panel Phone” – Enter a phone number for connection between the control • panel and TTE Combo. The phone number can be up to 16 digits long, as spaces, letters and special symbols are not allowed. Note: You must set the same phone number to the control panel, in the digital communicator programming menus.
  • Page 15 If the transmitting through one of the media is failed, the incoming events will be stored in the loop buffer of the module (TTE Combo). When the transmitting through the media is restored, all the stored events will be sent. In parallel reporting is obligatory the events to be successfully transmitted through all communication media.
  • Page 16: Gprs Settings Menu

    - For AJAX SP Pro Server. Leave empty. The fields will be filled in automatically after the registration of TTE Combo module to a User account at AJAX WEB – the user sets the mobile service provider according the selected country.
  • Page 17: Receiver Settings Menu

    “Main Receiver Port” – The Port of the Main Receiver server for monitoring. o “Encryption Key 1” – A special security encrypted key for the connection. The key is 32-symbols long and must be set one and the same at the TTE Combo and the server for monitoring for proper operation.
  • Page 18: Saving A Tdf File

    TTE Combo module configuration. 3.7 Writing a Configuration To upload the settings from ProsTE to the TTE Combo module you have to write them to the currently connected module. Select TTE Combo main menu and choose using the right mouse button: TTE Combo –...
  • Page 19: Ajax Web User Interface

    * Note: All previewed examples and screens below are based on this web application. 4.1 Creating an Account To be able to control your TTE Combo communication module, first you must have a User account registered to AJAX WEB User Interface (hereafter referred to as AJAX WEB).
  • Page 20: Adding A System To Account

    TTE Combo Communication Module – Installation and Programming Manual Attention: It is important to enter a valid e-mail address, so to be able to complete the registration and to receive in the future the information for the registered systems to your account at AJAX WEB.
  • Page 21 TTE Combo Communication Module – Installation and Programming Manual In case of registering of a TTE Combo module you have to make the following settings: - “System Name” – Enter a name describing the protected site. The name can be edited or changed later.
  • Page 22 Press Close button to exit the New Module Registration window. At this stage your TTE Combo is added to the System list but it is still offline, because the settings for the connection with AJAX SP Pro server are not set to the module yet.
  • Page 23: Online Connection With Ajax Sp Pro Server

    TTE Combo module. You can review the General Settings and Receiver Settings menus. There will be available the automatically set parameters from the server. Select in sequence using the right mouse button TTE Combo – Write to upload the settings into the module. Follow the steps as described in item 3.7 Writing a...
  • Page 24 The system is accessible when the button “Connect” is visible and active. To connect to a TTE Combo standalone module, press the button and enter the PC ID Number (1234 by default) – this is the password set with ProsTE – see also item 3.2 General Settings...
  • Page 25 TTE Combo Communication Module – Installation and Programming Manual “Delete” – Deleting the system from the list and from AJAX WEB. The site will ask for • confirmation. Note: Once deleted from the list and from the AJAX WEB, the system could not be restored again.
  • Page 26: Tte Combo - Installation Summary

    TTE Combo Communication Module – Installation and Programming Manual 5. TTE Combo – Installation Summary Here is a short list of the important steps necessary for successful connection of TTE Combo module to AJAX WEB. • Disable the PIN protection code of the SIM card for the module and place it in the holder.
  • Page 27: User Guide

    TTE Combo Communication Module – Installation and Programming Manual 6. USER GUIDE 6.1 AJAX WEB User Interface Using AJAX WEB interface, the user can remotely control the outputs of his TTE Combo module and to review the status of the Input (activated TAMPER). 6.1.1 Remote Access Login in your AJAX WEB User account and press “Connect”...
  • Page 28: Communication Module

    The output is turned ON (activated). The current information for all 3 terminals (PGMs) of TTE Combo is displayed as the User can review their current status. The outputs are remotely controlled with Turn ON/OFF button. The User can set different names for every terminal according its functionality in the system –...
  • Page 29: Mobile Tte Smartphone Application

    Mobile TTE is a smart phone application suitable for remote management of burglary control panels and modules produced by Teletek Electronics JSC. The application is compatible with Android and iOS platforms and can be downloaded directly from Google Play and App Store, or you can use the QR...
  • Page 30: Connection To A System

    MobileTTE Settings Menu). 6.2.2 Connection to a System To connect with the system – TTE Combo module standalone device, press the button and wait until the connection is established. When you are connecting to a system for the first time, you will be asked to enter a User code – this is the Password code set with ProsTE –...
  • Page 31: System Main Menu

    TTE Combo Communication Module – Installation and Programming Manual 6.2.4 System Main Menu There are some important settings for the system. After connection press “Menu” button in the right upper corner of the screen. Then choose Settings. The general functions of MobileTTE is to provide to the user remote control of the outputs of TTE Combo communication module, and to receive notification messages in case of alarm or trouble events and the arming status of the connected burglary alarm panel.
  • Page 32 By default, all types of events are enabled (it depends also of the settings in AJAX WEB). The number of set notifications will be visible on the screen. Note, these are events for the status of the connected burglary control panel to TTE Combo module (via digital communicator).
  • Page 33 TTE Combo Communication Module – Installation and Programming Manual In Settings menu the user can also set the visualization of events via red dot in the system list. Select the Red Dot Notification and select those type of events for which you want to be informed.
  • Page 34: Appendix - Sia Codes

    TTE Combo Communication Module – Installation and Programming Manual 7. APPENDIX – SIA CODES Event Code Description Address Field Code An analog fire sensor has been restored to normal Analog Restoral Zone or point operation. AC Restoral AC power of the control panel has been restored.
  • Page 35 TTE Combo Communication Module – Installation and Programming Manual Event Code Description Address Field Code Door Forced Door opened without access request. Door number Access Granted Door access granted. Door number Access Lockout Access denied, known code. Door number Access Open Access to authorized users allowed.
  • Page 36 TTE Combo Communication Module – Installation and Programming Manual Event Code Description Address Field Code Holdup Bypass Zone has been bypassed. Zone or point Holdup Alarm Restore Alarm condition eliminated. Zone or point Holdup Trouble Restore Trouble condition eliminated. Zone or point Holdup Restoral Alarm/trouble condition has been eliminated.
  • Page 37 TTE Combo Communication Module – Installation and Programming Manual Event Code Description Address Field Code There has been no zone activity for a programmed No Activity Zone number amount of time. Forced Perimeter Arm Some zones/points not ready. Area number Perimeter Armed An area has been perimeter armed.
  • Page 38 Tamper detection has been bypassed. Zone or point Test End Communicator restored to operation. Unused TAMPER Restored at TTE Combo module (IN1 Terminal). Zone or point Tamper Alarm Restore Walk Test Point This point was tested during a Walk Test. Point number Tamper Restoral Alarm equipment enclosure has been closed.
  • Page 39 TTE Combo Communication Module – Installation and Programming Manual Event Code Description Address Field Code Water Supervisory Water unsafe water detection system condition. Zone or point Water Trouble Water zone disabled by fault. Zone or point Water Unbypass Water detection bypass has been removed.
  • Page 40 TTE Combo Communication Module – Installation and Programming Manual Event Code Description Address Field Code Watchdog Reset The TRANSMITTER created an internal reset. Unused Problem with the connection to the control panel – line is broken or the phone device terminals are not...
  • Page 41 TTE Combo Communication Module – Installation and Programming Manual www.teletek-electronics.com Address: Bulgaria, 1407 Sofia, 14А Srebarna Str. Tel.: +359 2 9694 800, Fax: +359 2 962 52 13 e-mail: info@teletek-electronics.bg...

Table of Contents