Download Print this page
Peerless Pump PE-B Series Instructions Manual

Peerless Pump PE-B Series Instructions Manual

Advertisement

Quick Links

End suction pumps,
Close coupled series PE-B and PE-C;
Frame mounted series PB-B and PB-C
Read this entire book
before attempting to install, operate or repair this
pump. Properly installed, your Peerless pump will
give you satisfactory, dependable service. We urge
that you carefully read these step-by-step instruct-
tions to simplify any problems of installation,
operation or repair.
Failure to read and comply with installation and
operating instructions will void the responsibility
New equipment manufactured by Seller is warranted
to be free from defects in material and workmanship
under normal use and service for a period of one
year from date of shipment;
under this warranty being limited to repairing or
replacing at its option any part found to its
satisfaction to be so defective provided that such
part is, upon request, returned to Seller's factory
from which it was shipped, transportation prepaid.
This warranty does not cover parts damaged by
decomposition from chemical action or wear caused
by abrasive materials, not does it cover damage
resulting from misuse, accident, neglect, or from
improper
operation,
modification or adjustment. This warranty does not
cover parts repaired outside the Seller's factory
without prior written approval.
warranty
as
to
starting
apparatus or other material not of its manufacture,
since the same are usually covered by warranties of
the respective manufacturers thereof.
Peerless Pump Company
Indianapolis IN, 46207-7026
• Installation
• Operation
• Maintenance
Seller's obligation
maintenance,
installation,
Seller makes no
equipment,
electrical
Instructions
of the manufacturer and may also result in bodily
injury as well as property damage.
This book is intended to be a permanent part of your
installation and should be preserved in a convenient
location for ready reference.
should become soiled, obtain a new copy from
Peerless. Include pump model and/or serial number
with your request.
WARRANTY
In the event, notwithstanding the terms of this
agreement, it is determined by a court of competent
jurisdiction that an express warranty has been given
by Seller to Purchaser with respect to the head,
capacity or other like performance characteristics of
said equipment, Seller's liability for breach of the
same shall be limited to accepting return of such
equipment F.O.B. plant of manufacture, refunding
any amount paid theron by Purchaser (less
depreciation at the rate of 15% per year if Purchaser
has used the equipment for more than thirty (30)
days) and canceling any balance still owing on the
equipment.
THIS WARRANTY IS EXPRESSLY IN LIEU OF
ANY OTHER WARRANTIES, EXPRESSED OR
IMPLIED,
DISCLAIMS
MERCHANTABILITY
PARTICULAR PURPOSE.
If these instructions
AND
SELLER
SPECIFICALLY
ANY
IMPLIED
WARRANTY
OR
FITNESS
OF
FOR
A
2891096
Rev. 8/85

Advertisement

loading

Summary of Contents for Peerless Pump PE-B Series

  • Page 1 Read this entire book before attempting to install, operate or repair this of the manufacturer and may also result in bodily pump. Properly installed, your Peerless pump will injury as well as property damage. give you satisfactory, dependable service. We urge...
  • Page 2: Important Safety Precautions

    IMPORTANT SAFETY PRECAUTIONS Pump parts, and the tools and rigging equipment Before opening the conduit box or an electric motor, used in installing pumps, are heavy and may easily be certain that the current to the motor is shut off. cause normal precautions...
  • Page 3 FLOOR MOUNTING: A raised concrete foundation may filled. If debris is apt to be present, a combination foot- be provided for convenience of elevation, but it is not valve strainer should be used. When the suction is under required if the floor is level. If a concrete foundation is pressure, or the level of the water is above the pump, a provided it should be solid and rigid to support the valve and union should be installed in both the suction...
  • Page 4 CAUTION Make certain that the pump is free from PRIMING AND STARTING: When the pump is located alignment, resulting in a possible binding of the above the level of the liquid , the pump must be primed rotating element. Avoid springing the piping into line by filling the case and suction line through the tee in- and use caution when tightening the connections.
  • Page 5 Push in direction of pump end. If bearings (16-18) are to screw if one was provided. Install O-ring (73) into groove be removed, support on inner races and press shaft out. in case (1) and install onto adapter. Install screws and tighten uniformly to 10 ft-lbs.
  • Page 6: Locating Trouble

    5. The pump may be vapor bound- not fully primed. (See “Priming”.) Notice: Materials of construction, specifications, dimensions, design features, and application information, where shown in this bulletin, are subject to change and/or modification without notice by Peerless Pump at their option. 2891096...

This manual is also suitable for:

Pe-c series