Contents Teamline 5140 Installation Guide 22 May 2019 Before you install Teamline 5140 Prerequisites Skype for Business and Exchange requirements About the Teamline 5140 system The connectors Dimensions Connecting Teamline 5140 to peripherals Positioning the Teamline 5140 system Connecting network cables...
Page 3
Outbound Inbound Internal for Teamline 5140 System LED behavior Network port LED Using cameras with Teamline 5140 Setting up the Logitech MeetUp camera Installing cameras Examples of the maximum field of view Logitech BRIO and Rally 1.5m VHD-V71 at 2m...
Page 4
USB cables Camera cables VISCA cable requirements Pinout Cable color information Teamline 5140 safety and compliance information Installation Ventilation Servicing Power requirements Operating environment Approvals information EU/EEC Legal information Third party software acknowledgments Disclaimers and notices Teamline 5140 Installation Guide...
Before you install Teamline 5140 Before you install Teamline 5140 Before installing the Teamline system, read the Teamline 5140 safety and compliance information. Prerequisites Ensure you have: One or two commercial displays that support a 1080p60 input format Note: Interlaced input is not supported.
Page 6
Before you install Teamline 5140 4. Check the Get-CalendarProcessing calendar processing options for the room mailbox as follows: Meeting invitation emails sent to Teamline systems must contain the attachments created by the calendar event. Otherwise, the Join Now tile will not be displayed and meetings cannot be joined using the touchscreen.
USB 3.0 connector for cameras (USB 3.0) Dimensions The Teamline 5140 system is designed so that it doesn't need to be rack mounted; however, it can be wall mounted or mounted to the back of your display. Note: If you are using wireless (for example, Miracast) to connect devices to present content in meetings, ensure the system is not enclosed in a rack or behind a display.
Page 8
About the Teamline 5140 system Dimension Metric Imperial Width 150 mm 5.9 in Depth 152 mm 5.98 in Height 57 mm 2.24 in Teamline 5140 Installation Guide Page 7...
Connecting Teamline 5140 to peripherals Connecting Teamline 5140 to peripherals What's in the box? Teamline 5140 room system StarLeaf Touch touchscreen controller Pronto Wall mounting kit Cables Power cable Ethernet cable Two HDMI to HDMI cables (1.8 meters/5.9 feet) Patch cable (2 meters/6.6 feet) USB A to mini B (2.5 meters/8.2 feet)
Using non-matching settings causes severe packet loss. Connecting the touchscreen to the Teamline system Before you can use the StarLeaf Touch for your meetings, you must pair it with the Teamline system. To do this: 1. Connect the touchscreen to a Power over Ethernet (PoE) enabled port.
Mini DisplayPort to the display using the supplied cables, without the need for an audio injector. Note: If you have a Teamline 5140 system installed with an audio injector and you want to re-install it without the audio injector, contact StarLeaf Technical Support.
Connecting Teamline 5140 to peripherals Connect Pronto to the USB connector on the Teamline system using the USB-A cable, and ensure the other end of the cable is accessible to users to plug into their laptops. The first time users plug Pronto in, instructions are shown on the...
Connecting Teamline 5140 to peripherals Connecting power Using the supplied power cable, connect the DC +19V power connector on the rear of the system to the mains power. Teamline 5140 Installation Guide Page 12...
Mounting the Teamline 5140 system Mounting the Teamline 5140 system The Teamline 5140 system is shipped with a mounting kit containing a VESA mount bracket, which can be used to mount the system to the back of a display or to a wall.
Page 15
Mounting the Teamline 5140 system 3. Slide the system on to the VESA mount bracket. Note: The screws provided for mounting the bracket to displays may not fit all models. To attach and use the VESA bracket on a wall: 1.
Hosted if your system is managed by StarLeaf. Select On-premise you are using a local version of Maestro that has been installed by StarLeaf on your local network. Connecting the system to Maestro To connect the Teamline system to Maestro: 1.
IP address. In networking, toggle DHCP off and tap to enter the address, netmask, and gateway addresses. Note: If the address entered is invalid, you are not notified on the touchscreen. Ensure you enter the correct details. Teamline 5140 Installation Guide Page 17...
Local Maestro server or on-premise) Note: * denotes either config or fw. If you are using a proxy, the whitelist should be *.maestro.starleaf.com and maestro.starleaf.com if the first rule doesn't cover this 5355 Windows devices TCP/UDP Used to resolve names on...
If the Teamline system is not located on the same local network as the Skype for Business deployment (that is, if it connects using the Edge server), the following ports and protocols also apply. All source ports are ephemeral (1024-65535) unless otherwise specified. Teamline 5140 Installation Guide Page 19...
Port Host Protocol Notes Skype for Business Online servers TCP (HTTPS) Webticket, wsfed authentication Skype for Business Online servers TCP (TLS) SIP signaling Skype for Business Online servers TCP (PSOM/TLS) PSOM connections web conferencing Teamline 5140 Installation Guide Page 20...
Skype for Business Online (source port 50,000- servers 59,999) Other client Internal for Teamline 5140 All connections from the touchscreen controller to the Teamline 5140 system use IPv6 and always originate from ephemeral ports. Teamline 5140 Installation Guide Page 21...
Page 23
Ports and protocols Port Protocol Notes 69, 443, 5000, TCP (various StarLeaf internal endpoint control 5152, 23456 application layer protocols) Teamline 5140 Installation Guide Page 22...
Green/Yellow Data Rate LED When off, 10 Mb/s data rate is (On the right when looking selected. When green, 100 Mb/s is at the port) selected. When yellow, 1000 Mb/s data rate is selected Teamline 5140 Installation Guide Page 23...
Using cameras with Teamline 5140 Using cameras with Teamline 5140 The following cameras are supported with the Teamline 5140 system: Logitech BRIO VHD-V71 Logitech MeetUp Logitech Rally Very small to Small to large Very small to Medium to Use case...
3. Download and install the firmware upgrade. 4. To use the StarLeaf microphone with the MeetUp, ensure the microphone is attached to the Teamline system. 5. Reconnect the camera to the Teamline system and reboot the system. Installing cameras...
1. Connect the supplied USB 2.0 cable to the USB 2.0 connector on the camera. Connect the other end to the Camera In USB connector on the Teamline system. 2. Connect power to the DC 12V power input connector on the back of the camera. Teamline 5140 Installation Guide Page 27...
This topic helps you to configure your microphone(s) with the Teamline system. The 5140 system is shipped with a StarLeaf microphone. If required, a second StarLeaf microphone can be connected to the Teamline 5140 system.
Pinout for StarLeaf microphone cable The table below shows the pinout for the XLR-to-mini USB cable that is provided with the StarLeaf Microphone for use with StarLeaf room systems. Pins on XLR connector Pins on Mini USB connector Function Ground...
USB cables USB cables greater than 5 meters (16 feet) in length are not recommended. All USB extenders (such as active USB cables) are not supported by StarLeaf. Camera cables Teamline systems that include PTZ cameras are provided with 5 meter connection cables.
(you may need to modify the cables) Pinout The following diagram shows the pinout for the Camera Control connector on the rear of the Teamline room system: Pin Function Direction on the Teamline system Output Input Output Teamline 5140 Installation Guide Page 32...
If you are using cable extenders with VISCA cables, refer to the following pin color information. From the Teamline system: White is transmit Green is ground Red is receive From the camera: White is receive Green is ground Red is transmit Teamline 5140 Installation Guide Page 33...
Allow an adequate space around the unit to promote a good air flow for cooling of the Teamline 5140. Do not block the fan inlet or outlets. Ensure that the fan intake is not placed inline with the outlet from any other fan or convection cooled device.
Teamline 5140 safety and compliance information Environment Temperature Humidity Operating environment 0°C to 50°C 10% to 95% (non-condensing) Non-operating environment -40°C to 60°C 10% to 95% (non-condensing) Approvals information EU/EEC The Declaration of Conformity is available on request. Directive 2006/95/EC and 2014/35/EU (Low Voltage Directive):...
StarLeaf Limited. StarLeaf Limited reserves the right to revise this documentation and to make changes in content from time to time without obligation on the part of StarLeaf Limited to provide notification of such revision or change.
Need help?
Do you have a question about the Teamline 5140 and is the answer not in the manual?
Questions and answers