Summary of Contents for Swatch SWISS TIMING AQUATICS OSB 12
Page 1
OSB 12 Swimming Starting Block User’s Manual 3454.507.02 Version 1.4 Edition March 2020...
Page 2
Caution and safety precautions Never use any other charger than the supplied or a type approved by Swiss Timing. This could destroy the battery, cause damage to unit, and possible cause personal injury due to fire or/and electrical shock. ...
Swimming Starting Block / OSB12 TABLE OF CONTENTS INTRODUCTION......................1 Construction of the OSB12-RBD starting platform (Relay Break Detection) ....2 Construction of the OSB12 starting platform simple ............2 Fixation material for the platform ................... 3 INSTALLATION ......................4 Fixation of the OSB12 platform ..................
Swimming Starting Block / OSB12 1 INTRODUCTION OBS12 presents a powerful new patented feature, revolutionising the way the swimmers start from their blocks. Diving from the starting block with the body propelled by the knee at a 90° angle drastically increases the explosiveness of the start. Physical tests undertaken by top level swimmers showed faster races versus a standard block.
Swimming Starting Block / OSB12 3 TECHNICAL CHARACTERISTICS OF THE OSB12-SW WITH RELAY BREAK DETECTION (RBD) AND WITHOUT START CONTROL OSB12-RBD OSB12-Simple DIMENSIONS Plateform 740mm x 520mm x 38mm (165mm with footrest) WEIGHT (KG) 21.2 19.5 Platform white RAL 9010 with non-skidding surface COLOURS dark blue RAL 5002 / RAL 5017 since 2019 Closing at the moment of the...
4 CONTROL AND MAINTENANCE OF THE STARTING PLATFORM 4.1 Control without application of pressure Connect the buzzer to the connection cable. If there is no pressure on the platform (1), the buzzer remains silent. If the buzzer emits a sound, proceed as described in paragraph 4.5.
Swimming Starting Block / OSB12 4.4 Service Once a month: clean the starting platform with soft water and remove the outside sediments of oxidation. Every 6 months: check cable connections. Once a year: check rigidity of platform and footrest fixation. 4.5 Troubleshooting (detection of a short circuit) If the buzzer emits a sound while there is no pressure on the platform, proceed as follows: Unscrew the 4 nuts M8 on the platform (1).
4.8 Dismantling of the footrest Instruction for dismantling the footrest Unscrew the platform by removing the 6 screws located on the platform. Position the footrest on number 3 to access the screws between the footrest and the guides. Page 8 3454.507.02 Version 1.4...
Page 13
Swimming Starting Block / OSB12 Rotate the top to access the lateral screws. Unscrew the 4 screws (2 on each side). Pull to remove the footrest then remove the guides. To reassemble the footrest, start from this point and follow the instructions backwards. Version 1.4 3454.507.02 Page 9...
PREVENTION AND MAINTENANCE Equipment installed in aquatic complex, often sealed with a high moisture level, require special attention in regards to their maintenance. In fact, the stainless steel parts found on ladders, fences or swimming starting blocks can have corrosion if they are not frequently cleaned. Stainless steel is an excellent product that needs to be very clean to keep its stainless quality.
Page 15
Swimming Starting Block / OSB12 A weekly basic cleaning is required. A thorough cleaning must be done regularly, several times a year. You must use fresh water for cleaning. Never use abrasive material to clean the stainless steel parts. ...
APPENDIX 6.1 Version history Version Date Modifications since last version 05/11/09 Initial version 20/02/14 Addition of chapter 5 Prevention and Maintenance 24/04/14 Correction action force chapter 3, 4.2 and 4.7 26/06/14 Improvement of prevention and maintenance chapter (addition of silicon type B 431) 18/03/20 New blue RAL5017...