GUTMANN 32 EM 510x280 Installation Instructions Manual page 23

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 20
6. Create a screwed connection between the
hood/cupboard fixture and the fitted cupboard
(1.), and then tighten the cupboard fixture on
the hood (2.).
7. Direct the exhaust air hose and the
electrical line connection to the hood. Pay
attention that the exhaust air hose is installed
without kinks. Fasten the exhaust air hose to
the exhaust air connection using a hose
clamp.
8. Create the electrical connection between
the hood and the supply line.
9. In case of ceiling suspension by means
of threaded rods/hanger bolts: Use the
drilled fastening holes (X) at the top in the
hood body.
10. After completion of installation, carry
out a functional test.
Typ
32 EM 510x280 =
32 EM 810x280 =
32 EM1110x280=
Option: with mounting frame page 63
AttaAttachment points for threaded rods
32 EM 510x280 L: = 280 B: = 200
32 EM 810x280 L: = 500 B: = 200
32 EM1110x280 L: = 500 B: = 200
cutout dimensions
490 x 254mm
790 x 260mm
1090 x 260mm
en