HART 475 COMMUNICATOR
USER MANUAL
Hangzhou Zhongchuang Electron Co., Ltd
1

Advertisement

Table of Contents
loading

Summary of Contents for East Tester HART 475

  • Page 1 HART 475 COMMUNICATOR USER MANUAL Hangzhou Zhongchuang Electron Co., Ltd...
  • Page 2: Table Of Contents

    Catalog 一.Product List Confirmation..............3 二.Product Introduction ............... 3 三.Working Environment...............4 四.Keyboard Introduction ..............4 五.Establish Connection ..............4 六.Funtion Introduction ............... 6 七.Common Function Operation Example..........9 八.Polling Meter............错误!未定义书签。 九.Battery Power................. 12 十.Instrument Information ..............12 十一.Language Selection ..............12 十二.Resistance Connection ..............13 ............
  • Page 3: 一.Product List Confirmation

    Thank you for purchasing the HART series of handheld communicators. In order to use your HART Communicator well, please read all instructions carefully and keep the manual in a safe place for all users of this product. Product list 一. Serial number Product name Quantity...
  • Page 4: 三.Working Environment

    instrument, configure the set parameters of HART instrument, read the test value and set value of the instrument, and diagnose and maintain the instrument.This manual operator supports the first main device of HART protocol, as well as the point-to-point and multi-point communication mode of HART protocol. Working Environment 三....
  • Page 5: 五.Establish Connection

    五.Establish Connection 5.1 Establish HART loop connection The communicator can be connected to the remote control room or the instrument on the spot to communicate with the instrument independently. There is 250 Ω resistance in internal set of communicator , and can be freely connected or disconnected.Set as connectting internal resistance,there is no need to connect external...
  • Page 6: 六.Funtion Introduction

    HART METER Figure 7-3 Connection Guidance with no external resistance 5.2 Turn on and Turn off HART 475 First, check if the battery of communicator has been equiped well. After the meter loop is connected correctly, hold down the power button for three seconds and the LCD screen is lit to indicate that the device has been working.
  • Page 7 When the loop equipment is a pressure, differential pressure and pressure or differential pressure instrument, please select the first “pressure menu”; when the loop equipment is a temperature meter, please select the second “temperature menu”; For the other HART devices Please select the third "Universal Menu". 6.1 Menu Number There are 6 selections : 1 online device, 2 polling device, 3 battery power, 4 local information, 5 language, 6 resistance connection...
  • Page 8 6.3 Reading process variable Select the first item in the main menu to enter the function of reading process variables. The process variables listed in this menu include principal variables, output current and percentage value, etc., and are updated in real time with each communication 1Master variable *** Kpa...
  • Page 9: 七.Common Function Operation Example

    display variables, some variables can only read, some can write operations;The third is to perform a series of operations to complete a specific function, the user only need to complete according to the operation steps. 1 Manufacturer 5 Device Info 2 Device Type 6 Version 3 Serial Number...
  • Page 10 Click the following operation to enter the unit function of setting pivot variables: (4 detailed Settings) → (2 signal conditions) → (1 user range unit) 7.2 set the upper limit of the range The upper limit of the range can be set by following: (4 detailed Settings) →...
  • Page 11 八.Polling instrument After starting up, the communicator will automatically poll the online device with address 0.Select "polling device" from the project menu and it will enter the option of polling device. If there are multiple instruments on the line at the same time, you can ensure the communication with the required instruments through single point and polling.The first item in the menu is multi-point polling.
  • Page 12: 九.Battery Power

    must set a different address.If the devices are with the same address, it may not be found by communicator,then a separate connection is required to modify the polling address of the device.HART protocol defines the communication mode of multiple devices connected in the same loop as multi-point communication mode. The current of the loop is no longer 4-20ma, but the sum of the output current of these devices.
  • Page 13: 十二.Resistance Connection

    . Resistance Connection 十二 Select item 6 from the item menu to enter the resistance connection selection screen.Can switch the connection or disconnection of the built-in resistance.Select item 1 as the internal resistance connection, and item 1 is shown as "connected"; no need external resistance connection / Select item 2 to disconnect the internal resistance connection.
  • Page 14: 十四.Attention

    Attention 十四. 14.1 for the first use, please read the instructions in detail to make the best use of your operator. 14.2 take good care of the products, keep them clean and dry, keep them free from dust and moisture, avoid being soaked or knocked, handle them gently and avoid man-made damage.