AIRREX DEHUMIDIFIER MODEL : ADH-100 USER'S MANUAL ▶ It is essential that you read ‘SAFETY INSTRUCTIONS’ carefully ▶ Thank you for purchasing the unit. before use and follow them at all times. Before operation please read this user’s manual carefully.
TABLE OF CONTENTS ■ SAFETY INSTRUCTIONS ■ GENERAL ADVICE BEFORE USE ■ EXTERIOR DESCRIPTION ■ SPECIFICATIONS ■ CONTROL PANEL FUNCTIONS ■ HOW TO SET THE 'OFF' TIMER ■ HUMIDITY CONTROL OPERATION ■ 'ERROR' and WARNING INDICATORS ■ TROUBLE SHOOTING ■ CLEANING AND MAINTENANCE ■...
Page 3
SAFETY INSTRUCTIONS WARNING Use a circuit breaker for the capacity. (It may cause fire and electric shock) The following symbols are for your guidance: = You must NOT. = You MUST. Before cleaning, disconnect the unit. (Otherwise risk of electric shock) Do not use a damaged power cable.
SAFETY INSTRUCTIONS CAUTION Do not place this unit on uneven, unstable or inclined surface. (This could cause malfunction) When storing this unit, keep it in a dry, cool place. (To prevent corrosion and malfunction) If not being used for some time or if lightening is present, always disconnect from power. (To prevent risk of electric shock, short circuit or fire) Do not spray water onto this unit nor use solvents such as benzene, thinner or alcohol for cleaning.
EXTERIOR DESCRIPTION FRONT VIEW DIGITAL CONTROLLER AIR INLET EVAPORATOR FILTER CONDENSED WATER OUTLET CASTER (REAR 10'') CASTER (FRONT LOCKABLE) BACK & SIDE VIEW BACK HANDLE AIR OUTLET PUMP BUTTON POWER CORD...
SPECIFICATIONS MODEL ADH-100 Maximum 32 (86℉ 80%) Capacity gal/day Nominal 22 (80℉ 60%) Power supply 115Vac 60Hz 1Ph Air Flow ft³/min Power Consumption Current Consumption Refrigerant R-410A / 2.2 Dimensions (WxDxH) inch 19.9 x 21.8 x 39.2 Weight Air Filter Vinyl Chloride Mesh Catridge ▶...
CONTROL PANEL FUNCTIONS ⑧ ⑥ ⑨ ⑦ ④ ⑤ ⑩ ③ ① ② ① Power : Use to power on / off. ② Button : Raises or lowers the setting temperature or sleep (off) time. ③ Fan : Controls fan speed. High / Medium / Low ④...
HOW TO SET THE ‘OFF’ TIMER This function enables you to set the length of time you want the unit to operate. You can set the time period from 30min. to 24 hours in 30min. and 1 hour increments. Humidity. 1.
HUMIDITY CONTROL OPERATION •When you turn ON, the setting humidity is displayed. Current Humidity •You can change setting humidity. •The display showing the set humidity will blink 3 times. Setting Humidity •When you push either ▼ or ▲ button, the setting humidity Setting Humidity is changed.
‘ERROR’ and WARNING INDICATORS Error Code Problem Cause Corrective Action High pressure Blocked air filter Ensure exhaust duct is not Blocked / kinked exhaust duct blocked / kinked Current Humidity Ambient temperature is too high Do not use the air conditioner if ambient temperature is higher than 113℉...
TROUBLE SHOOTING TROUBLE CHECK REMEDY Power cable correctly connected Connect cable correctly Power button "OFF" Press POWER button to "ON" Fuse (supply) blown Exchange fuse in board WORKING Breaker on switch board tripped Check load capacity and reset Ambient temp. too high Check operating temp.
CLEANING AND MAINTENANCE CLEANING THE AIR FILTERS ② ① 1. To remove filters, open the front case ①, and pull towards you. ② 2. Clean the filters with water or compressed air. 3. Clean heat exchanger unit with a vacuum cleaner or compressed air. MAINTENANCE 1.
WARRANTY (Applicable to first retail purchaser only) AIRREX unit gives the more reliable performance, comfort and durability the more they are used. They are built under a strict quality assurance regime which includes inspection both during and after production and exhaustive reliability testing.
Need help?
Do you have a question about the ADH-100 and is the answer not in the manual?
Questions and answers