Long Term Storage:
1. Unscrew the fuel cap.
2. Using an approved siphon (Figure 11.1),
remove the Kerosene or diesel.
3. Using a small amount of Kerosene or diesel,
rinse and swirl the fuel inside the fuel tank
NOTE: NEVER MIX WATER WITH FUEL. It will
cause rust inside the tank.
4. Empty the tank completely.
IMPORTANT: Never store leftover Kerosene
between seasons, using old fuel can
damage heater.
Figure 11.1
Store Heater in a dry, well ventilated area.
-
Be sure that the storage area is free of dust
and corrosive vapors. Repack the heater
in the original packaging and keep user's
manual in an easily accessible place.
Service:
Never service heater while it is
WARNING
plugged in or hot!
DO NOT TAMPER WITH THE UNIT. HAVE AN
EXPERIENCED SERVICEMAN MAKE ANY
NECESSARY ADJUSTMENT OR REPAIRS.
© 2020, Lavorwash
NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE
CONNECTED TO A POWER SOURCE
Maintenance - PT70-SS Plus
We suggest following a maintenance schedule as
follows:
TIP: Follow the long term storage
instructions to flush the tank.
FUEL / FUEL TANK:
Flush tank every 200 hours of operation or as
needed. DO NOT flush with water, use fresh
Kerosene only.
SPARK PLUG:
Clean and re-gap every 600 hours of operation
or replace as needed. After removing the Spark
Plug, clean the terminals with a wire brush.
Re-gap the terminals to 0.140" (3.5mm).
(See Figure 11.2)
Figure 11.2
FAN BLADES:
The fan blades should be cleaned at least once
per heating season, depending on conditions.
Remove all accumulated dust and dirt with a
burst of condensed air. (See Figure 12)
Figure 12
Diesel Fired Radiant Heater User's Manual
9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pt-125 ss

Table of Contents