NOTE*
Your Battery will arrive in transportaion mode, to preserve shelf life.
It is not possible to operate (discharge) the battery until the battery is placed on the charger. It is recommended that a
battery is fully charged before first use.
Read all these warnings before using the charger.
CAUTION! Charge only Numatic Lithium-Ion batteries,
other types of batteries may burst causing personal injury and damage.
Check the mains cord regularly for any sign of damage. If the mains cord of the charger is damaged,
it must be replaced by an original NUMATIC INTERNATIONAL cord available from the manufacturer or
service agent.
Do not use damaged devices.
Protect the charger against moisture and store it in a dry place.
Do not use the charger if it is wet.
The mains voltage available must correspond to the voltage stated on the rating plate of the charger.
Do not operate charger in explosive environment.
Do not carry the charger by holding the mains cord.
Do not handle the electrical cord or plug, with wet hands.
Do not unplug by pulling on cord. To unplug, grasp the plug, not the cord.
Do not cover the charger.
Do not open the charger. Repairs shall be done only by authorised personnel.
Do not charge damaged batteries.
Do only charge dry batteries.
Do not charge non-rechargeable batteries in this charger.
Warning
The battery included in this product must only be charged by the Numatic Charger
supplied with the product under NO circumstances should an alternative non Numatic charger be used as there is risk
severe damage and fire could result. Only use genuine Numatic parts.
The charger is intended for use only on flat surfaces, place horizontally on floor or work suface. The charger is intended
for use with the power cord supplied, the power unit is capable of
operating at different voltages without user adjustment.
If your charger is fitted with a non detachable cable this can only be changed by an authorized service partner.
Make sure cable replacements are a genuine Numatic service part.
If the charger is damaged or does not charge anymore, do not use and contact your supplier.
Charging Procedure:
1.
Ensure the battery is fully inserted into the charger.
2.
Fit the mains power cord to charger and suitable power supply.
3.
Charger Status Lights table, (see page 11).
Health Hazards (Acute & Chronic).
The chemicals used in the battery are in a sealed container.
Risk of exposure only occurs if the battery is abused or damaged.
Contact of electrolyte and lithium with skin and eyes should be avoided.
Signs & Symptoms of Exposure.
A damaged or leaking battery can cause chemical burns upon contact.
If exposed to any of the Chemicals mentioned in the Hazards section please follow the procedures below:
Eyes.
Flush eyes with plenty of water for at least 15 minutes, occasionally lifting the upper and lower eyelid.
Seek medical attention.
Skin.
Remove contaminated clothing and rinse skin with plenty of water or shower for 15 minutes.
Seek medical attention.
Inhalation.
Vacate from site of exposure to fresh air immediately. Use oxygen if available.
Ingestion.
Give at least two glasses of milk or water. Induce vomiting unless patient is unconscious.
Seek medical attention.
Note:
Inhalation, skin contact and eye contact are possible if the battery is damaged.
Exposure to internal contents, the corrosive fumes will be very irritating to skin, eyes and mucous membranes.
Overexposure can cause symptoms of non-fibroid lung injury and membrane irritation.