WBOX Technologies 0E-RCKMT1000 User Manual

WBOX Technologies 0E-RCKMT1000 User Manual

Rackmount series

Advertisement

Available languages

Available languages

EN
USER'S MANUAL
Rackmount Series
0E-RCKMT1000 / 0E-RCKMT1500 / 0E-RCKMT2200
K01-1101046-02
COPYRIGHT © 2019 ADI

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 0E-RCKMT1000 and is the answer not in the manual?

Questions and answers

Summary of Contents for WBOX Technologies 0E-RCKMT1000

  • Page 1 USER’S MANUAL Rackmount Series 0E-RCKMT1000 / 0E-RCKMT1500 / 0E-RCKMT2200 K01-1101046-02 COPYRIGHT © 2019 ADI...
  • Page 2: Important Safety Instructions

    IMPORTANT SAFETY INSTRUCTIONS This manual contains important instructions. Please read and follow all instructions carefully during installation and operation of the unit. Read this manual thoroughly before attempting to unpack, install, or operate the UPS. CAUTION! To prevent the risk of fire or electric shock, install in a temperature and humidity controlled indoor area free of conductive contaminants.
  • Page 3: Installing Your Ups System

    (f) Warranty registration card; (g) Software download card AUTOMATIC VOLTAGE REGULATOR (AVR) The 0E-RCKMT1000 / 0E-RCKMT1500 / 0E-RCKMT2200 can stabilize inconsistent utility power. Incoming utility power fluctuations may be damaging to important data and hardware but Automatic Voltage Regulation (AVR) helps protect the computer against experiencing dangerous voltage levels. AVR automatically adjusts low or high voltages to keep equipment working at safe AC power levels (120V) without switching to battery.
  • Page 4 INSTALLING YOUR UPS SYSTEM (continued) Plug the UPS into a 2 pole, 3 wire grounded receptacle (wall outlet). Make sure the wall branch outlet is protected by a fuse or circuit breaker and does not service equipment with large electrical demands (e.g.
  • Page 5: Basic Operation

    BASIC OPERATION FRONT / REAR PANEL DESCRIPTION 1. Power Switch Master on/off switch for equipment connected to the UPS. 2. Power On Indicator An LED ring around the Power Switch indicates that the AC utility input power condition is normal and that the UPS outlets are providing power, free of surges and spikes.
  • Page 6: Battery Replacement

    CAUTION! Risk of Energy Hazard, 12 V, maximum 7Ah (for 0E-RCKMT1500) or 9Ah (for the 0E-RCKMT1000 and 0E-RCKMT2200) battery. Before replacing batteries, remove conductive jewelry such as chains, wrist watches, and rings. High energy conducted through these materials could cause severe burns.
  • Page 7 BATTERY REPLACEMENT (continued) BATTERY REPLACMENT PROCEDURE Remove the front panel on the right side. Disconnect the black wire and red wire from the battery. Remove the four retaining screws. Insert the new battery pack. Assemble the screws, cable and front panel in the reverse sequence of above steps.* Recharge the unit for 18 hours to ensure the UPS performs expected runtime.
  • Page 8 DEFINITION FOR ILLUMINATED LCD INDICATORS Input Voltage Meter: This meter measures the AC voltage from the wall outlet. The INPUT voltage readout is used to identify the input voltage information. This can be used as a diagnostic tool to identify poor-quality input power. Units are listed in V (Volts).
  • Page 9: General Mode

    LCD SETUP FUCTIONS 1. GENERAL MODE Press the Display toggle button to check the status of the UPS status: Items Unit Input Voltage Output Voltage Output Frequency Load Load Capacity Battery Capacity Estimated Runtime If the LCD backlight turns off (enters sleeping mode), press the Display toggle button to wake it up. 2.
  • Page 10 LCD SETUP FUCTIONS (continued) Functions Options Description 136V It is the setting of maximum output voltage. If the utility voltage is usually 139V high and the connected equipment can work with this condition, you can set High 142V Transfer Point higher to avoid UPS going High Transfer Point to battery mode too often.
  • Page 11: Fault Warning Display And Alarm

    FAULT WARNING DISPLAY AND ALARM DURING SHUTDOWN The following table shows each corresponding warning message on LCD screen and the alarm reacts during the machine shutdown (output-off): LCD Warning Alarm Condition Solution Display Turn the UPS off, unplug at least one Constant piece of equipment from battery Overload in line mode.
  • Page 12: Troubleshooting

    TROUBLESHOOTING Problem Possible Cause Solution Turn the UPS off and unplug at least one piece Circuit breaker has tripped of equipment. Wait 10 seconds, reset the due to an overload. circuit breaker and then turn the UPS on. Batteries are discharged. Recharge the unit for at least 8 hours.
  • Page 13: Technical Specifications

    TECHNICAL SPECIFICATIONS MODEL 0E-RCKMT1000 0E-RCKMT1500 0E-RCKMT2200 INPUT Nominal Input Voltage 120Vac Input Voltage Range 88Vac – 139Vac Input Adjustable Voltage 86Vac – 142Vac Range Input Frequency Range 60Hz +/- 3Hz Input Plug Type NEMA 5-15P NEMA 5-20P OUTPUT Output Capacity...
  • Page 14: Limited Warranty And Connected Equipment Guarantee

    LIMITED WARRANTY AND CONNECTED EQUIPMENT GUARANTEE 1. LIMITED WARRANTY General Subject to the terms and conditions of this Limited Warranty, from the date of sale through the period of time for product categories specified in Section 1(b), ADI warrants its W Box Technologies products to be free from defects in materials and workmanship under normal use and service, normal wear and tear excepted.
  • Page 15 LIMITED WARRANTY AND CONNECTED EQUIPMENT GUARANTEE (continued) Product Categories Warranty Period Intrusion Audio Devices 30 months Video Surveillance Monitors 30 months Power and Relays 30 months Hold-up Buttons 30 months Video Surveillance Baluns 30 months Smoke Detectors 36 months DVR's, NVR's 60 Months excluding HDD;...
  • Page 16 LIMITED WARRANTY AND CONNECTED EQUIPMENT GUARANTEE (continued) 2. EXCLUSION OF WARRANTIES, LIMITATION OF LIABILITY THERE ARE NO WARRANTIES OR CONDITIONS, EXPRESS OR IMPLIED, OF MERCHANTABILITY, OR FITNESS FOR A PARTICULAR PURPOSE OR OTHERWISE, WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. TO THE FULLEST EXTENT PERMITTED BY LAW, IN NO CASE SHALL ADI BE LIABLE TO ANYONE FOR ANY (I) CONSEQUENTIAL, INCIDENTAL, INDIRECT, SPECIAL, OR PUNITIVE DAMAGES ARISING OUT OF OR RELATING IN ANY WAY TO THE PRODUCT AND.OR FOR BREACH OF THIS OR ANY OTHER WARRANTY OR CONDITION, EXPRESS OR IMPLIED, OR UPON ANY OTHER BASIS OF LIABILITY...
  • Page 17: Governing Law

    LIMITED WARRANTY AND CONNECTED EQUIPMENT GUARANTEE (continued) 4. RETURNS Subject to the terms and conditions listed below, during the applicable warranty period, ADI will replace Product or provide a credit at purchase at its sole option free of charge any defective products returned prepaid.
  • Page 18 COST) of the equipment at of the time of the damage. CyberPower uses Orion Blue Book, or other a third-party valuation guides, or eBay, craigslist, or other source to establish that amount. The maximum liability is limited to $300,000 for the 0E-RCKMT1000, 0E-RCKMT1500 and 0E-RCKMT2200. COPYRIGHT © 2019 ADI...
  • Page 19: Safety Compliance Statement

    SAFETY COMPLIANCE STATEMENT FCC COMPLIANCE STATEMENT This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
  • Page 21: Manuel De L'utilisateur

    MANUEL DE L'UTILISATEUR Série Montage sur baie 0E-RCKMT1000 / 0E-RCKMT1500 / 0E-RCKMT2200 COPYRIGHT © 2019 ADI...
  • Page 22: Consignes De Sécurité Importantes

    CONSIGNES DE SÉCURITÉ IMPORTANTES Ce manuel contient des directives importantes. Veuillez lire attentivement et respecter toutes ces instructions lors de l'installation et de l'utilisation de l'unité. Veuillez lire attentivement ce manuel avant de déballer, d'installer ou d'utiliser l’ASI. ATTENTION! Pour éviter tout risque d'incendie ou de choc électrique, installez l'appareil en intérieur, dans une zone où...
  • Page 23: Schéma Du Système

    RÉGULATEUR AUTOMATIQUE DE TENSION (AVR) Le 0E-RCKMT1000 / 0E-RCKMT1500 / 0E-RCKMT2200 peut stabiliser l'alimentation électrique irrégulière. Les fluctuations dans l'alimentation d’entrée peuvent causer des dommages aux données et matériels importants; le régulateur automatique de tension (AVR) permet de protéger l’ordinateur contre les niveaux dangereux de tension.
  • Page 24 INSTALLATION DE VOTRE SYSTÈME ASI (suite) Branchez l'ASI dans une prise mise à la terre trifilaire et bipolaire (prise murale). Assurez-vous que la prise de dérivation murale soit protégée par un fusible ou un disjoncteur et n'alimente pas d'équipement à forte consommation électrique (p. ex. un climatiseur, un photocopieur, etc.). En vertu de la garantie, l'utilisation de rallonges électriques, de multiprises et de parasurtenseurs est strictement interdite.
  • Page 25: Fonctionnement De Base

    FONCTIONNEMENT DE BASE DESCRIPTION DU PANNEAU AVANT/ARRIÈRE 1. Interrupteur d'alimentation Interrupteur marche/arrêt principal pour l’équipement branché à l'ASI. 2. Voyant d'alimentation Un anneau à DEL autour de l’interrupteur d'alimentation indique que l’alimentation électrique CA d’entrée est normale et que les sorties de l'ASI fournissent du courant, sans surtensions et crêtes. 3.
  • Page 26: Remplacement Des Batteries

    ATTENTION! Risque de danger électrique, batterie 12 V, maximum de 7 Ah (pour l’0E-RCKMT1500) ou de 9 Ah (pour l’0E-RCKMT1000 et 0E-RCKMT2200). Avant de remplacer les batteries, ôtez vos bijoux conducteurs, comme les chaî nes, les montres et les bagues.
  • Page 27 REMPLACEMENT DES BATTERIES (suite) Vérifiez si la batterie est mise à la terre. Si c'est le cas, retirez la source de mise à la terre. ATTENTION : TOUT CONTACT AVEC UNE BATTERIE MISE À LA TERRE PEUT ENTRAÎ NER UN RISQUE DE CHOC ÉLECTRIQUE! La possibilité...
  • Page 28 DÉFINITION DES VOYANTS LUMINEUX DE L'ACL Voltmètre d'entrée : Ce dispositif mesure la tension CA de la prise murale. L’affichage de la tension d’ENTRÉE permet d’identifier les renseignements sur la tension entrante. Cela peut être utilisé comme outil de diagnostic afin d'identifier les sources d'alimentation de moindre qualité.
  • Page 29 FONCTIONS DE CONFIGURATION DE L'ACL 1. MODE GÉNÉRAL Appuyez sur le bouton bascule de l’affichage pour vérifier l'état de l'ASI : Objets Unité Tension d’entrée Tension de sortie Fréquence de sortie Charge Capacité de charge Capacité de la batterie Autonomie estimée Si le rétroéclairage de l'ACL s'éteint (entre en mode veille), appuyez sur le bouton bascule de l’affichage pour le réactiver.
  • Page 30 FONCTIONS DE CONFIGURATION DE L'ACL (suite) Fonctions Options Description Il s’agit du paramètre de tension de sortie 136 V maximale. Si la tension électrique est 139 V normalement élevée et si l'équipement peut fonctionner sous cette condition, vous 142 V pouvez hausser le point de transfert élevé...
  • Page 31 AFFICHAGE ET ALARME D’AVERTISSEMENT DE DÉFAUT DURANT UN ARRÊT Le tableau suivant présente chaque message d’avertissement correspondant sur l'ACL et les réactions de l'alarme durant l'arrêt de la machine (arrêt de sortie) : Affichage Alarme Condition Solution d'avertissement ACL Éteignez l'ASI, débranchez au moins un Tonalité...
  • Page 32: Dépannage

    DÉPANNAGE Problème Cause potentielle Solution Le disjoncteur a été Éteignez l'ASI et débranchez au moins un déclenché à la suite d'un élément. Attendez 10 secondes, réinitialisez le phénomène de surcharge. disjoncteur, puis rallumez l'ASI. Les batteries sont Rechargez l’unité durant au moins 8 heures. déchargées.
  • Page 33: Caractéristiques Techniques

    CARACTÉRISTIQUES TECHNIQUES MODÈLE 0E-RCKMT1000 0E-RCKMT1500 0E-RCKMT2200 INPUT (Entrée) Tension d'entrée nominale 120 VCA Plage de tensions d’entrée 88 VCA à 139 VCA Plage de tensions d’entrée réglable 86 VCA à 142 VCA Plage de fréquences d’entrée 60 Hz +/- 3 Hz Type de fiche d’entrée...
  • Page 34: Garantie Limitée

    GARANTIE LIMITÉE ET GARANTIE DE L'ÉQUIPEMENT CONNECTÉ 1. GARANTIE LIMITÉE Général Sous réserve des modalités de la présente garantie limitée, à compter de la date de vente et pendant la période de garantie applicable aux catégories de produits précisées au paragraphe 1(b), ADI garantit que ses produits W Box Technologies sont libres de tout vice de matériaux et de fabrication dans des conditions d’utilisation et d’entretien normales, sauf l’usure normale.
  • Page 35 GARANTIE LIMITÉE ET GARANTIE DE L'ÉQUIPEMENT CONNECTÉ (suite) Product Categories Warranty Period Protection contre les surcharges 24 mois Haut-parleurs pour le plafond 24 mois Modules de requête de sortie 24 mois Distributeurs HDMI 24 mois Serrures magnétiques 24 mois Amplificateurs 24 mois Parasurtenseur 6 prises 24 mois...
  • Page 36 GARANTIE LIMITÉE ET GARANTIE DE L'ÉQUIPEMENT CONNECTÉ (suite) 2. EXCLUSION DE GARANTIES ET LIMITATION DE RESPONSABILITÉ IL N’EXISTE AUCUNE GARANTIE OU CONDITION, EXPRESSE OU IMPLICITE, DE QUALITÉ MARCHANDE, D’ADAPTATION À UNE FIN PARTICULIÈRE OU AUTRE QUI DÉPASSE LE CADRE DE LA DESCRIPTION FOURNIE AU RECTO DES PRÉSENTES.
  • Page 37 GARANTIE LIMITÉE ET GARANTIE DE L'ÉQUIPEMENT CONNECTÉ (suite) 4. Retours Sous réserve des modalités énumérées ci-après, durant la période de garantie applicable, ADI remplacera le produit ou donnera une note de crédit à l’achat, à son gré et sans frais, à l’égard de tout produit défectueux qui lui est retourné.
  • Page 38 (ET NON À LA VALEUR DE REMPLACEMENT) au moment des dommages. CyberPower utilise Orion Blue Book ou d’autres guides d'estimation tiers, eBay, Craigslist ou d'autres sources pour déterminer ce montant. L'obligation maximale se limite à 300 000 $ pour l'0E-RCKMT1000, l’0E-RCKMT1500 et l’0E-RCKMT2200.
  • Page 39 DÉCLARATION DE CONFORMITÉ AUX NORMES DE SÉCURITÉ DÉCLARATION DE CONFORMITÉ AUX NORMES DE LA FCC Cet appareil est conforme à la partie 15 de la règlementation FCC. Son utilisation est soumise aux deux conditions suivantes : (1) cet appareil ne doit pas causer d’interférences nuisibles, et (2) doit accepter toute interférence reçue, y compris les interférences pouvant entraî...

This manual is also suitable for:

0e-rckmt15000e-rckmt2200

Table of Contents

Save PDF