  • Page 1 ES-D5B Wireless Smoke Detector Instrukcja pobrana ze sklepu www.ekocentrum24.pl...
  • Page 2 . 7 Warning: unsuitable installation . 10 Standards . 13 Images, illustrations and text are non-contractual . ETIGER and the ETIGER logo are registered trademarks and the property of ETIGER . Copyright © 2014 ETIGER . All rights reserved .
  • Page 3: Box Content

    . However, this smoke detector can only send an alert if located, installed, and taken care of according to the instructions in this user manual . Box Content ES-D5B x1 Mounting bracket x1 AA 1 . 5 V batteries x2 Documentation...
  • Page 4: Specifications

    Dimensions: Ø120 x 35 .5 mm Reference: ES-D5B | Model: GS558 Installation Connect the ES-D5B to your alarm system Switch to Connection Mode on the control panel . Press and hold the test button on the detector for 3 seconds . The control panel beeps once: the detector is registered .
  • Page 5: Operating Test

    The detector is working: make sure the LED blinks once every 40 seconds . If so, the detector is in normal detection mode . When the smoke detector triggers an alarm, the alarm will not stop until the air is smoke-free again . Operating test Press and hold the test button for 6 seconds .
  • Page 6 clockwise . Press the test button and make sure the detector can work properly . Care It is recommended to open the cover and remove the dust in the detector’s smoke chamber at least once a year . Remove the battery before cleaning the detector . Remove the dust with a vacuum cleaner (attached to a soft brush) .
  • Page 7 Installation guidelines Smoke detectors must be installed according to the European standard CE EN 14604 . For a complete coverage of your home, the detectors must be installed in every room, storage area, cellar, attic and corridor . The minimum number of detectors to be installed is one on each floor, one in every bedroom and one in the attic .
  • Page 8 Bathroom Toilets Dining room Kitchen Figure 1 Locations of smoke detectors in individual houses Bedroom with one bedroom Living room Smoke detectors for optimal safety Smoke detectors for basic safety Living room Kitchen Bathroom Toilets Dining room Figure 2 Bedroom Locations of smoke detectors in single- floor houses with...
  • Page 9 In the cellar, install the detectors near the stairs On the second floor, install a detector at the top of the stairwell leading from the first to the second floor . Make sure no door nor any obstacle will prevent the smoke from reaching the detector Install additional detectors in your living room, your dining room, in the common area, the attic and in the storage areas or in the...
  • Page 10 Smoke detectors for Detector basic safety Figure 5 Recommended location Horizontal distance from for an installation under the top of the ceiling a sloped ceiling Air ow Bedroom Bath- room Unsuitable installation Kitchen Figure 6 Recommended smoke detector locations to avoid air streams with combustion particles Bedroom Living room...
  • Page 11 away from places where combustion particles are usually present like kitchens . If the 6-meter distance cannot be respected, e .g . in a mobile home, try to install the detector as far from the combustion particles as possible, preferably on the wall . In order to prevent false alarms, make sure these locations are well ventilated .
  • Page 12 In stagnant air areas . Stagnant air areas are often at the top of a peaked roof, or in the corners between ceilings and walls . Stagnant air areas may prevent smoke from reaching the detector . Refer to figures 4 and 5 for recommended mounting locations .
  • Page 13 Standards This product bears the selective sorting symbol for waste electrical and electronic equipment (WEEE) . This means that this product must be handled pursuant to European Directive 2002/96/EC in order to be recycled or dismantled to minimize its impact on the environment .