CUMBERLAND Alert Alarm III
Owners Manual
Cumberland
1004 E. Illinois St.
Assumption, IL 62510
Part No. 4801-1201 Rev 1-20
Owners Manual
Alert Alarm III
• Phone 217-226-4421
• Fax 217-226-4420
CUMBERLAND
Assumption, IL 62510

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Alert Alarm III and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Cumberland Alert Alarm III

  • Page 1 CUMBERLAND Alert Alarm III Owners Manual Cumberland 1004 E. Illinois St. Assumption, IL 62510 Part No. 4801-1201 Rev 1-20 Owners Manual Alert Alarm III • Phone 217-226-4421 • Fax 217-226-4420 CUMBERLAND Assumption, IL 62510...
  • Page 2: Table Of Contents

    Page Product Description ............................1 Ratings and Specifications ..........................1 Warnings ................................ 1 Using the Alert Alarm III ..........................2 The Control Panel ........................... 2 High Limit Setpoint ..........................2 Low Limit Setpoint ..........................2 Alarm Sources Display ........................... 2 Power ON/OFF ............................
  • Page 3: Product Description

    1. Product Description The Cumberland Alert Alarm III is an automatic audible alarm system that can trigger an alarm from temperature sensors or other sensors connected remotely to the controller including other Farm Hand controllers. Individual adjustments on the Alert Alarm III provide for setting the high and low alarm temperatures while a front panel display contains status indicators and test functions.
  • Page 4: Using The Alert Alarm Iii

    4.7 Sensors The Alert Alarm III comes from the factory with two temperature sensors. It is important to note that these sensors are fabricated using thermistors and are not interchangeable with sensors that are commonly used on controllers from other manufacturers.
  • Page 5: Power Out

    5.1 Battery Low If the battery in the Alert Alarm III gets down to around 11 volts, the battery low alarm condition will be active. This is very common if the Alarm has sounded for some time. If this situation exists, the Alarm should be set so that no alarm condition exists, and the battery allowed to recharge.
  • Page 6: Power Out

    Note also, any 12VDC device which uses less that 1 amp of current could be connected in the siren’s place. Part No. 4801-1201 Rev. 1-20 Alert Alarm III...
  • Page 7: Recommendations

    (3) Use a relay with a 12VDC coil and a separate battery/charging system for any installation where the siren must be fifty feet or more from the controller. Part No. 4801-1201 Rev. 1-20 Alert Alarm III...
  • Page 8: Schematic Diagram

    7. Schematic Diagram Part No. 4801-1201 Rev. 1-20 Alert Alarm III...
  • Page 9: Alarm Connections To Other Farm Hand Controllers

    Alert Alarm III Series Alarm Connection This is the proper way to connect the Farm Hand family of auxillary alarm outputs to an Alert Alarm III. The Alert Alarm III activates when the connection is broken between the Sig and Gnd terminals.
  • Page 10: Temperature Vs. Sensor Resistance Table

    42.2 16.465 57.2 9.007 81.3 27.4 4.82 108.5 42.5 16.312 57.6 14.2 8.891 81.9 27.7 4.763 42.8 16.085 58.1 14.5 8.815 82.2 27.9 4.688 109.8 43.2 15.935 58.5 14.7 8.702 82.8 28.2 Part No. 4801-1201 Rev. 1-20 Alert Alarm III...
  • Page 11 GSI warrants, subject to all other conditions described in this Warranty, Service Parts which it manufactures for a period of 12 months from the date of purchase, unless specified in Enhancements above. Parts not manufactured by GSI will carry the Manufacturer’s Warranty. (Protein Limited Warranty_REV01_ 06 November 2018) Part No. 4801-1201 Rev. 1-20 Alert Alarm III...