Safety Precautions WARNING ・ Read these Safety Precautions carefully before using the device in order to use it correctly. The following persons should not use the device. ・ Use the device sensibly in accordance with the prescribed steps. ・ Immediately discontinue use if any malfunction or unusual reaction to treatment May cause an accident or other problems. ・ undergoing a medical treatment; in a physical growing stage; occurs. suffering from an acute disease; ・ Do not use the device in a defective state, as doing so could cause a physical ・ tuberculous disease; fever; hypertension; infectious disease; harm to the user. ・ malignant tumor; blood disease; visceral disease; skin disease; ・ The precautions listed in the Userʼs Manual are very important. For your safety, allergic constitution; please follow them carefully. ・ atopic dermatitis; skin problems; severely fatigued; ・ Precautions are classified as DANGER, WARNING, or ATTENTION in order to ・...
Page 3
WARNING WARNING Do not use the device near a Use with an operating Do not damage, break, Grip the plug head when flammable substance (such modify, bend by force, pull, voltage range from 100 - unplugging the AC adapter as alcohol, thinner, benzene, twist, or bundle the AC 240 V. from the device or a power nail polish remover, or adapter. Make sure the AC adapter outlet. spray). is fully inserted into a Do not insert or disconnect Prohibited Do not place heavy objects Must power outlet. the plug with wet hands. Disconnecting Failure to comply may cause a on the AC adapter or allow it Careless or comply fire, an electric shock or injury. Failure to comply may cause to get pinched in between the plug Failure to comply may cause reckless use a fire, electric shock or other objects as this may an electric shock, short accident.
When Using Outside of Japan ATTENTION 注 意 WARNING Do not wipe the device with Do not use the device on alkali cleaning agent, alcohol, pets. thinner, benzene, nail polish Failure to comply may cause remover, or other such an injury. Be sure to use in an operating voltage range from 100 - Prohibited substances. 240 V. Prohibited Failure to comply may cause a damage to the surface of the Do not place the device in an Failure to comply may cause a fire, an electric shock, or a malfunction of the Must comply device. unstable location. device. Do not drop or strike the Avoid contact between the device. Be sure to check the plug configuration and the voltage of the electrode head and metal Doing so may cause a Dropping surfaces. power outlet before use. malfunction of the device. prohibited An injury may also be caused if Failure to comply may cause a Combustion Failure to comply may cause a generation of heat, ignition, or a malfunction of ...
Features 【Accessories】 ●Cotton Stopper This product is a facial beauty device that provides skin care through Ion Cleansing, EMS, Photo, Cool, DYHP and Micro-current functions (Silver Ring) while warming the skin with Radio Frequency (hereinafter referred to as * The cotton stopper is attached to the electrode ʻRFʼ). head when purchased. It can be used to suit your personal skin condition and to achieve your * Use this stopper to fix cotton to the electrode head. objective by combining the following available treatment modes. ●AC Adapter ●RF: Warming the skin to the deep layer* to prepare a better condition for the treatment. ●Ion Cleansing: Absorbs dirt that cannot be removed with normal face washing with the power of ions. AC Adapter ●EMS: Stimulates the muscles with an electrical current. ●Photo: Treats your skin with LED Photo treatment. Adapter Plug ●Cooling: Tightens your skin with a cooling effect. * The design and specifications of the main unit and accessories are ●DYHP: The original wave helps lotion to permeate into* the skin. subject to change for improvements without prior notice. ●Micro-current: Treats around the eye area with gentle electrical current. Before Use * To the stratum corneum Names and Functions of Components How to Read the Panel ●Indicator and Buttons ●Main Unit ・ Press and hold the Power/Mode <Front> <Rear> button for approx. 3 seconds to Hand Electrode (Silver Rim on Rear) turn on the device (the treatment will automatically ...
Page 6
●Mode Indicator ●Charging Indicator <Charging> <Fully charged> The charging indicator will flash while Each time you press the Power/Mode button, the treatment mode will be the device is charging. selected in the following order: Clean→Eye Care→Moisture→EMS Up→ When charging is complete, the Cool→Clean (repeat). charging indicator will turn solid. * Not shown during use CLEAN EYE CARE MOISTURE EMS UP COOL (Flashing) (Solid light) ●Notice Timer Alarm Function EMS / Cool / RF / RF / RF /DYHP You will hear a beep after the first half of the treatment time with the LED (red) LED (blue) Ion Cleansing Micro-current LED (red and orange) selected mode. When you hear a beep, use the device on the other side of your face. ●Standby and Auto-off (Automatic Power Off) When Clean, Eye Care, Moisture, and EMS Up modes finish (3 minutes for each mode), the indication of the next mode blinks and the device will be on standby status* (not in operation). * When you press the Power/Mode button, the next mode that is waiting in Standby status will start. * If the next mode does not start within approx. 2 minutes, the device will ○...
Page 7
How to Charge About the Treatment Modes Frequency Operating The product is rechargeable and can be used either with or without being Mode Features Function Recommendation Level (rough Time standard) connected to an AC adapter. Always use the device after charging when you use it without an Absorbs dirt RF Booster Pad Pore ・RF which cannot be electrical cord. Refining Deep Approx. Treatments Ion: removed with Cleansing 3 2 - 3 times ・ Before using it for the first time, or if you have not used the device for normal face 5 levels ・Ion (or cotton and your minutes per week washing and an extended period, fully charge the battery and make sure that the Cleansing regular skin lotion tones your skin. Charging indicator has turned from flashing to solid, indicating a full ...
How to Use ●How to Apply Treatment Remove makeup and gently cleanse your face. Attaching Cotton to the Head ・ Remove oil and dirt from your skin so that it is in a clean condition prior to treatment. * Cool mode can be used over makeup. Remove the cotton stopper Attach cotton if necessary and apply lotion onto from the electrode head. the cotton. Press and hold the Power/Mode button for Place a piece of cotton on top of the approx. 3 seconds to turn on the power. Select electrode head and press the cotton the mode and intensity level. stopper down over the cotton. ・ Select the mode using the Power/Mode button. ・ Select the intensity level using the Level button. * If the cotton stopper does not fit properly on the electrode head, please use a * The intensity level cannot be selected for RF, Micro Current, LED, larger and thinner cotton. Thick cotton may not fit well, so it should be torn in half. and Cool mode. * If the cotton is too thick, the thermal action of the RF treatment may be * Always select Level 1 upon the first use and until you are adversely affected and you will feel less heat. accustomed to use. When holding the device, make sure that you are Apply your regular skin lotion or gel onto the touching the hand electrode (silver rim) on the cotton. rear of the device. * ...
Page 9
How to Apply the Device on Your Skin Move the electrode head over the skin in the direction of the arrows shown below. <Clean and Moisture Mode> Press and move the device in a circular, massaging motion as ・ If the temperature feels too hot, move the head little quicker. You can indicated by the arrows. also use cotton to prevent the heat. Areas that can only be treated ・ Use in a position in which the entire surface of the electrode head with LED light. comes into contact with your skin. (See below about how to use.) ・ Be sure to move the device on your skin during use. * Close your eyes and hold the Using the device continuously on the same area may lead to burns and low temperature burns. electrode head 5 cm or more ・ Do not put the electrode head on the eyelids or around the eyes. away from the skin. Areas you should not treat. Approx. 3 minutes Areas that can only be treated Left Right Standby with LED light in Moisture Approx. Approx. side 90 seconds 90 seconds display side...
After Treatment Troubleshooting To keep the product hygienic, please be sure to clean it after each use. Checklist for Possible Problems ●How to Clean and Store the Product Problem Possible Causes Solutions Ensure the power is off and unplug the AC The Power/Mode Press and hold the adapter from the device. button is not being Power/Mode button → → pressed long for approx. 3 seconds To clean the electrode head and cotton stopper, enough to turn on the device Does not turn on wipe it with a damp and well-wrung cloth to Please charge the → → remove dirt. Wash the cotton stopper with water. Insufficient device or connect charging the main unit to ・ Remove the cotton stopper from the main unit, wash it with → → the AC adapter water, then wipe it dry. ・ Do not use an alkali cleaning agent, alcohol, thinner, benzene, nail Contact a local The battery life ...
Page 11
Problem Possible Causes Solutions Frequently Asked Questions Cool mode was Turn off the device → → used continuously and wait at least 30 without any interval minutes before use Cool mode is not cool enough Try using in an The device is being used → → How much lotion This device is designed to feel more environment with a in an environment with a temperature of warmth with sufficient amount of lotions or temperature exceeding or gel should I use the recommended range gel. 15° C - 30° C each time? Apply lotion on cotton enough to make the The setting level is Lower the intensity surface of the electrode head all wet. → → too high Use gel about the size of 2 pearls. with Level button Irritating/painful We recommend adding more lotion or gel if ...
Price: 3,000 yen (excluding tax) ・ If you need a battery replacement, contact your local agent. RF Booster Pad Clear Deep Moisturizer ●Disposing of the Device Product Name: RF Booster Pad Clear Deep Moisturizer ・ Follow your local government rules for proper disposal of this product. QTY: A set of 15 sheets per box (for 1.5 - 2 months) ・ This product uses a lithium ion battery. Product Code: YRFOOO4 Price: 3,000 yen (excluding tax) ●Contacts for overseas customers For countries and regions outside Japan, please contact the store where you have purchased your product for any inquiry about it. Alternatively visit URL: www.ya-man.com YA-MAN Global Official Website (https://www.ya-man.com/en/). Note: The products may be discontinued without notice. ●Product Specifications 9 V 2.0A Rated Power Supply Approx. 15W Power Consumption Lithium ion battery Battery Approx. 3 hours (may vary depending on the Battery Charging Time charging environment). Main unit (with cotton stopper): Outside Dimensions Approx. W50 x D55 x H190 (mm) Main unit (with a cotton stopper): Approx. 270 g Weight Main unit: ABS resin ...
Need help?
Do you have a question about the Photo PLUS Prestige S and is the answer not in the manual?
Questions and answers