Hardware Operation; Power Up Led Sequence; Led Flash Sequences; Netlight Led Operation - Lascar EL-SMS-2G-TP User Manual

Temperature monitor with sms alerts
Table of Contents

Advertisement

User Guide

Hardware Operation

Power up LED sequence

When the unit is powered on, the following LED flash sequence is displayed:
Red LED, Green LED, No LED's

LED Flash Sequences

Start up flash sequence
Red LED, Green LED 0.5s each
Status display
4 green flashes = Setup not yet attempted.
(standby mode)
5 red flashes = Setup attempted but failed.
Short push of status button.
1.5s red LED = Low battery
Setup mode sequence
1 red flash every 5 seconds = Not ready to receive
5 second push of status
SMS.
button
2 green flashes every 5 seconds = Ready to
receive SMS.
Status display (Run mode)
2 red flashes = In alarm condition (Highest priority)
Push of status button
3 red flashes = Low battery (Medium priority)
1 green flash = Running, no alarm conditions (Low
priority)
Stop monitoring
Green LED on for 3s then off for 3s followed by
reset.
Unit "Configured" status is cleared.
SIM Card Error
4 red flashes every second for approximately
10 minutes.
EL-SMS-2G-TP / TP+ / PROBE-G USER MANUAL

Netlight LED Operation

The orange Netlight status LED will show you the status of the internal 2G GSM
module when it is in use. The flash sequences displayed by the Netlight are as
follows:
Off
GSM module is powered off.
1 second flash
GSM module is not registered on a mobile network.
2 second flash
GSM module is registered on a mobile network.

Sounder

The unit is fitted with a sounder which is used to indicate various operating
conditions as follows:
Ready for configuration message
Configuration message received
No configuration message received
OR message was not compatible
with the unit
Triple beep
Double beep
Five short beeps
Page 15 of 24
Issue 1

Advertisement

Table of Contents
loading