3.6.2.10.3 Console Redirection Settings

Item
Out-of-Band Mgmt Port
Terminal Type
Bits per second
Flow Control
Option
Microsoft Windows Emergency Management Services
COM0[Default]
(EMS) allows for remote management of a Windows
Server OS through a serial port.
VT100
VT-UTF8 is the preferred terminal type for out-of-band
VT100+
management. The next best choce is VT100+ and then
VT-UTF8[Default]
VT100. See above, in Console Redirection Settings
ANSI
page, for more Help with Terminal Type/Emulation.
9600
Selects serial port transmission speed. The speed must
19200
be matched on the other side. Long or noisy lines may
57600
require lower speeds.
115200[Default]
Flow control can prevent data loss from buffer overflow.
When sending data, if the receiving buffers are full, a
None[Default]
'stop' signal can be sent to stop the data flow. Once the
Hardware RTS/CTS
buffers are empty, a 'start' signal can be sent to re-start
Software Xon/Xoff
the flow. Hardware flow control uses two wires to send
start/stop signals.
Quick Reference Guide
legacy OS. Default setting for this option is set to
Always Enable.
Description
EGS-MX1 Quick Reference Guide 67