Gianni Industries NH-Indoor Series Installation Instruction page 2

Electromagnetic lock

Advertisement

With LZ bracket for In-swinging doors
1
Find a mounting location on the
door frame for the L bracket. Make
sure that the door is still closeable.
5
Put one rubber washer between
armature plate and the Z bracket.
Connecting Diagram
Status LED:
GREEN: Unlocked
RED : Locked
Off: No power
Sensor input
Voltage Selection jumpers
12Vdc
Check jumper settings before
connecting the lock to 24 VDC
input power. Damage to the
24Vdc
lock may result from incorrect
jumper settings.
Trouble Shooting
Problem
Door does not lock
Reduced holding force
Sensor output is not functioning
Copyright © 2008 Gianni industries, inc. All rights reserved.
P-MU-AM-EM-N Ver. F
Published on 2008.06.19
2
Tighten the electromagnetic lock
on the L bracket by using the
fixing screw.
6
Close the door. Measure the correct
position by bringing the armature
plate close to the contact surface of
the electromagnetic lock.
Door Position Sensor
Orange:
N.O.
White:
Com.
Brown:
N.C.
Trigger
Relocking timer
Timer Adjust
Shorten
Coil
Possible Cause
No power
Poor contact between electromagnet and
armature plate
Low voltage or incorrect voltage setting
A secondary diode was installed across
the electromagnet
Misalignment between the reed switch
and its magnet
3
Assemble the Z bracket, and make
sure that the Z bracket is adjustable.
7
Turn on the power of EM-Lock,
and let the armature plate bonds
to the EM-lock. Adjust the position
between the Z bracket and the
door frame.
N.C. output while door is opened ; N.O.
output while door is closed to the
electromagnetic lock.
The electromagnetic lock will automatic
unlock internally after the triggers connect to
each other. The time for the door to relock
back is depending on the "VR timer adjust"
within90 seconds.
Magnet bond
sensor output
N.C.
COM.
N.O.
Power
Input
Door Held Open Alarm
The time for the
timer adjust"within 90 seconds..
If the "
Door Held Open Alarm
will happen: If the door has been opened , but has remained open for
more than 5 seconds then an audible alarm will sound until the door
has been closed correctly.
Check to make sure the wires are securely tightened to the correct terminal block
Check that the power supply is connected and operating properly
Make sure the lock switch is wired correctly
Make sure the lock switch is wired correctly.
Make sure the electromagnet and armature plate are properly aligned
Make sure the contact surfaces of the electromagnet and armature plate are clean
and free from dust
Ensure the electromagnetic lock is set for the correct voltage.
Check for proper voltage at the electromagnetic locks input. If low, determine if the
correct wire gauge is being used to prevent excessive voltage drop.
Remove any diode installed across the magnet for "spike"
suppression. (The magnet is fitted with a metal oxide varistor to prevent back EMF)
Check the installation of armature with supplied template.
4
Insert the guide pins into the
armature plate.
Finish
Power
Once the position is correct,
use the screws to permanently
mount the Z bracket on the door
frame. This should be the last step.
N.C. output while door is unlocked ;
N.O. Output while door is locked by
the electromagnetic lock.
Control Device N.C. contact or
Access Relay
"Door Held Open Alarm
"
is depending on the "VR
"
timer is set for 5 seconds, the following
Solution
Power
supply

Advertisement