Thermostat Connection - GE UUY24ZGDAA Installation Instructions Manual

Table of Contents

Advertisement

Available languages

Available languages

Installation Instructions
Thermostat Connections
(Only for air handler without electric heater)
Y
B
W1
Thermostat
R
C
G
ATTENTION: Thermostat must energize reversing valve in heat mode using the "B" terminal.
Indoor Unit - 2/3 ton
Power
L1
L2
G
G
Thermostat
Note:
1. Please refer to the instruction manual to check whether the unit can connect to the engineering electric heating.
2. When the unit doesn't connect to the engineering electric heating, connect the engineering power supply to the W5(BK) and W6(WH) of X1.
3. When the unit connects to the engineering electric heating, connect the engineering power supply to the breaker.
4. The primary input voltage of transformer is defaulted at 230V(BK). When switching the power supply of the complete unit to 208V, connect the
primary input voltage of transformer to 208V(BU), which can be realized by exchanging the black wire and the blue wire.
5. 1 Only applicable for the unit whose motor is with earthing wire.
16
L1
L2
Power
G
L1
L2
Power
G
W5
W6
XT1
1
W3
X1
1
1
W4
N 2
W1 W2
XT2
Y
Y
Y
Y
X1 X2
W7 W8
B
B
B
B
W13
X10
W1
W1 W1
W1
W9
R
R
R
X4
R
W10
C
C
C
X3
C
W11
G G
G
TC
WH
YE
See Note
CB1
G
XT1
8kw Heat Kit
X1
L1
L2
Note:
Indoor Unit
XT2
1. Please refer to the Instruction Manual to check
Y
whether the unit can connect to the engineerig
B
electric heating.
W1
R
2. When the unit doesn't connect to the engineering
C
electric heating, connect the engineering power
G
supply to the L1 and L2 of wiring board.
3. When the unit connects to the engineering electyric
heating, connect the engineering power supply to
the breaker.
XT1
L1
L2
XT2
Outdoor Unit
Y
B
W1
R
C
G
L1
G
G
CB1
2 3 4 5 6
X1
8KW HEAT KIT
W12
CN1
COM2
AP1
Fan motor
X9
X13X7
XT3
1
BU
BK
RD
CB1
X1
L2
CB1
Heat
AP2
DC_MOTOR1
Code
CB1
TC
XT1~XT3
Y
XT1-1
RD
M
B
signal, energized under
BK
XT1-2
YEGN
W1
Heater control signal
G
R
24V AC power supply
C
G
Indoor unit fan signal
Name
Circuit breaker
Transformer
Wiring board
4-way valve control
the heating mode
24V common
31-5000486 Rev. 2

Advertisement

Table of Contents
loading

This manual is also suitable for:

Uuy36zgdaaUuy48zgdaaUuy60zgdaa

Table of Contents