Lg optimus l9 has a sophisticated, slim design that easily fits in your purse or pocket, and high-end features you can take with you anywhere. (58 pages)
Safety Precautions Safety Precautions To prevent injury to the user or other people and property damage, the following instructions must be followed. n Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by the following indications.
Page 4
Safety Precautions Do not use a defective or underrated circuit breaker. Use the correctly rated breaker and fuse. Otherwise there is a risk of fire or electric shock. Install the panel and the cover of control box securely. Otherwise there is risk of fire or electric shock due to dust, water etc.
Page 5
Safety Precautions 1.2 Inspections after Repair Check to see if the terminal block is not dirty or loose. If terminal block is dust or loose it can cause an electrical shock or fire. Do not use a joined power cable or extension cable, or share the same power outlet with other electrical appliances.
Standards for Model Standards for Model AHCM Series 000 : Multi V, Single Model Classfication R :Return Air Control S :Supply Air Control Model Type AHCM : AHU Comm. Kit Accessory Type - 6 -...
Troubleshooting Troubleshooting 1.1 Error Indicator (Comm.Kit) Problem Cause Remedy Check the electrical connection and voltage of the No power supply power supply. Check the electrical connection of the AHU Communication Kit Wiring is wrong Communication Kit (Refer to the circuit diagram of does not work the Communication Kit) AHU Communication...
Page 15
Troubleshooting [Error Code (Outdoor Unit)] • This page is about outdoor error code. It can vary depending on outdoor unit. For more information, please refer to the outdoor unit manual. Display Title Cause of Error Outdoor unit Inverter Compressor IPM Outdoor unit Inverter Compressor Drive IPM Fault Fault Inverter Board Input Over Current(RMS) of...
Page 16
Troubleshooting [Error Code (Outdoor Unit)] • This page is about outdoor error code. It can vary depending on outdoor unit. For more information, please refer to the outdoor unit manual. Display Title Cause of Error Outdoor unit Constant Speed Compressor1 Discharge Outdoor unit Constant Speed Compressor1 Discharge Temperature Sensor Fault Temperature Sensor open or short...
Page 17
Troubleshooting [Error Code (Outdoor Unit)] • This page is about outdoor error code. It can vary depending on outdoor unit. For more information, please refer to the outdoor unit manual. Display Title Cause of Error Communication Error Between Failing to receive Slave Unit signal at main PCB Outdoor unit and Other Outdoor Unit of Outdoor unit Outdoor unit Fan PCB...