Page 2
All rights reserved. No reproduction of all or part of this document, in any form, is permitted without the written consent of Oldham Simtronics S.A.S. All of the information that is provided in this document is accurate to the best of our knowledge.
Page 3
SIMTRONICS, even though they may be involved in the sale of OLDHAM SIMTRONICS products. OLDHAM SIMTRONICS shall not be responsible for any direct or indirect damage, or any direct or indirect consequence, resulting from the sale and use of any of its products UNLESS SUCH PRODUCTS HAVE BEEN SELECTED BY OLDHAM SIMTRONICS ACCORDING TO THE APPLICATION.
Page 4
(EEE) or a point of exchange for authorized products in the event of the acquisition of a new product of the same type as before. MultiXplo / MultiTox Page 4 / 60 NOSP15759-Rev 10...
These detectors can be configured also using the Hart portable terminal TLH700 (in option). The MultiXplo and MultiTox are also available for use in an addressable network system with distributed intelligence, SYNTEL. For more information, please refer to the Syntel module interface operating manual.
(DM-TX6-X) and brown for catharometers (DM-TT6-K). The cartridge is located in the lower part of the detector, and it is connected to the detector body by an open ring leaving the label visible. MultiXplo / MultiTox Page 8 / 60 NOSP15759-Rev 10...
1.5. Detection Cartridge Detection Cartridges are explosion proof designed. They are common to all Oldham Simtronics MultiXplo and MultiTox-K products in order to reduce the number of spare parts. DM-RX6-X and DM-RT6-K: Network versions for Syntel loop, • DM-TX6-X and DM-TT6-K: « Telecapteur » versions, •...
Page 11
The HART output is an option. It is available only on the devices equipped with an electronic type C, in HART configuration (H):DGi-**7-****-**H-**-***-*-C-* OLDHAM SIMTRONICS devices under HART protocol enable the use of all the functions available with the TLU600 via the HART terminal.
4-20 mA protocol (Common fault signal 2 mA) 4 – 20 mA / 0-22 mA configurable & HART protocol 4 – 20 mA / 0-22 mA configurable Wheatstone 4 – 24 mA for compact explosimeter (magnet) MultiXplo / MultiTox Page 12 / 60 NOSP15759-Rev 10...
Page 13
Special paint : light grey (10A03 according to « British standards 4800/5252 ») Special paint : red (RAL 3001) Machining of additional cable gland input Paint thickness > 200 µm(ATEX versionIIB) MultiXplo / MultiTox Page 13 / 60 NOSP15759-Rev 10...
Page 14
Language Fr / GB French English Portuguese Chinese Hardware version Type 63 Type 65 Type 67 (HART) Type 69 (magnet) Software version Standard MultiXplo / MultiTox Page 14 / 60 NOSP15759-Rev 10...
TECHNICAL FEATURES GENERAL Type Gas detector DM-TX6-X MultiXplo (catalytic gas detector) DM-TT6-K MultiTox (catharometer gas detector) DM-RX6 or DM-RT6 Network detector Calibration Factory set, recommended test every 6 months OUTPUT SIGNALS 4-20mA loop signal Type active (source) maximum load impedance 700Ω...
Page 16
Material stainless steel 316 L or epoxy coated aluminium Weight 2.3kg (5.1 Lbs) (Aluminium) 4 kg (14.3 Lbs.) (Stainless steel) ATEX/IECEx Please refer to § 8 Dimensions Figure 2: Outline drawing MultiXplo / MultiTox Page 16 / 60 NOSP15759-Rev 10...
Effect of O –enriched or 15 % O 10 % O 15 % O None depleted atmospheres min. min. min. Warm-up or biasing time 90 secs 120 secs MultiXplo / MultiTox Page 17 / 60 NOSP15759-Rev 10...
Page 18
For external probe versions, temperature range is limited to -20 / +60 °C Under conditions of natural diffusion and available on any of the outputs of the device (HART, 4-20mA, ...). MultiXplo / MultiTox Page 18 / 60 NOSP15759-Rev 10...
(gas density, ambient temperature…) There are no limit positions of the detector however it is recommended to position the detector vertically (ie with the cartridge pointing downwards). Air velocity limits: 6 m/s. MultiXplo / MultiTox Page 19 / 60 NOSP15759-Rev 10...
Fit the main housing on the base, placing the excess of cable in the base. Make sure to correctly tighten the 2 fixing screws once the correct position has been obtained. Figure 4 : Housing orientation MultiXplo / MultiTox Page 20 / 60 NOSP15759-Rev 10...
Page 21
(M20). On stainless steel version, they are glued with Loctite or equivalent compound. If a plug is moved or removed, it must be glued again with Loctite or an equivalent. MultiXplo / MultiTox Page 21 / 60 NOSP15759-Rev 10...
Never adjust electric connections when detectors are powered. Maintenance must be undertaken by qualified staff. Observe safety site rules. The MultiXplo and MultiTox are sensors with standard current output (4-20mA or 0-22mA). The connection can be on 3 or 4 wires. The 4 wires configuration allows insulation between the signal and power loops.
Page 23
The total loop resistance should not exceed 700 Ω with a voltage of 24Vdc. Terminal blocks Point JP11 Description +24VDC power supply +24VDC power supply loop (connected to point 2) 0 V, Connected to point 1 20mA Current loop: entry 20mA Current loop: output MultiXplo / MultiTox Page 23 / 60 NOSP15759-Rev 10...
Page 24
The 20mA current loop must be supplied with a PLC. The current return must be connected to the 0V at the level of the L- terminal. To proceed, please connect the 4 (V-) and 6 (L-) terminals at the terminal block level of the devise. MultiXplo / MultiTox Page 24 / 60 NOSP15759-Rev 10...
Page 25
In the last case, the relay are opens when the • detector is no longer powered. • on one or more states of the detector (fault, permanent Inhibition, alarms). Relays configured at factory setting : refer to 6.7.5.1 MultiXplo / MultiTox Page 25 / 60 NOSP15759-Rev 10...
Page 26
NB : The R1 value is given as an indication. It must comply with the following conditions: • Minimum consumption = 5 Watts • Maximum dissipation = 2.5 Watts MultiXplo / MultiTox Page 26 / 60 NOSP15759-Rev 10...
Page 27
• A white wire on the other N (no specific edge) • Figure 5: Connecting drawing of the network versions For more detail, thanks to refer to the operating manual NOSP15251 MultiXplo / MultiTox Page 27 / 60 NOSP15759-Rev 10...
Page 28
The hosted sensor NEEDS to get its own power The connecting wires to another detector are limited to a 1 mm² section. Using this board leads to a connection between 0V from power supply and housing ground. MultiXplo / MultiTox Page 28 / 60 NOSP15759-Rev 10...
Page 29
1.5mm². The table below shows the maximum cable lengths according to the cable section. Minimum copper conductor section in mm² (AWG) 0,5 (20) 0,9 (18) 1,5 (16) Maximum length 15 m 30 m MultiXplo / MultiTox Page 29 / 60 NOSP15759-Rev 10...
O-ring. Then, tighten the locking screw. Switch on the device in order to make the calibration of the new cartridge and the zero adjustment. MultiXplo / MultiTox Page 30 / 60 NOSP15759-Rev 10...
Logic Controller. It results in the flashing of the green LED in the communication head. 5.3. Operational tests All MultiXplo / MultiTox detectors are delivered set and tested. Some additional tests are necessary to check the good working of the loop. Please make sure to have all authorizations needed before running the following operations: •...
The permanent inhibition is activated by an order issued by the TLU when an operation is performed at/or around the device, or when the operator wants to inhibit a faulty device. The permanent inhibition must be removed by an operator’s deliberate action using the TLU. MultiXplo / MultiTox Page 33 / 60 NOSP15759-Rev 10...
6.5. Wireless communication tool TLU600 All settings and tests of detectors can be done by the wireless communication tool TLU600. This communication tool and its software are compatible with all Oldham Simtronics detectors: MultiFlame, MultiTox and MultiXplo. Communication is made via infrared link (IrDA), similar but more efficient than infrared links for computers.
Page 35
Changing displayed value. • Validation and Check-in of the changed value. • The changed value must be confirmed by pressing [VAL] key, otherwise the old value will kept when leaving menu. MultiXplo / MultiTox Page 35 / 60 NOSP15759-Rev 10...
Page 36
Maintenance : • The access to the parameters and other maintenance operations is protected by a password. Default password (6 digits which can be changed): 012345. MultiXplo / MultiTox Page 36 / 60 NOSP15759-Rev 10...
Syntel system operating manuals. NETWORK SCREEN: ALIM Information displayed: • Voltage A: ON / OFF • Voltage B: ON / OFF For any further details, please refer to the Syntel system operating manuals MultiXplo / MultiTox Page 37 / 60 NOSP15759-Rev 10...
Selecting the inhibition mode will switch the detector in inhibition mode. The message “End of inhibition” is displayed on the TLU. Press on “End of inhibition” to get the detector back to normal operating mode. MultiXplo / MultiTox Page 38 / 60 NOSP15759-Rev 10...
Page 39
The detector is in maintenance inhibition mode for 10 minutes after it goes back to main screen. Use the setting menu and validate the INH command for acknowledgement. Press F4 key to stop communication between TLU600 and the detector. MultiXplo / MultiTox Page 39 / 60 NOSP15759-Rev 10...
Page 40
Use the setting menu and validate the INH command for acknowledgement. To end of communication between the TLU600 and the detector is done by pressing F4 key on main menu. MultiXplo / MultiTox Page 40 / 60 NOSP15759-Rev 10...
Page 41
Press [>>] to go to the next figure in the field. • Press [PAGE] to go next page. • The label or zone modification must be confirmed by pressing the key VALID, otherwise the modification is not taken into account MultiXplo / MultiTox Page 41 / 60 NOSP15759-Rev 10...
Page 42
Power loss C1-T1 open Output current configuration This menu allows you to switch the format of the output current between 4-20 mA and 0-22 Factory setting: the output current is 4-20 mA MultiXplo / MultiTox Page 42 / 60 NOSP15759-Rev 10...
SPIN sends the detectors network identification. • LIEN switches from normal mode to logic link mode. • SWITCH enables the switches to go on mode open/closed/open secured. • MultiXplo / MultiTox Page 43 / 60 NOSP15759-Rev 10...
The device then goes in warm-up mode (refer to §6.3) for 90s. The detector is in inhibition mode. The current output and the default relay (if factory configuration) are consequently activated. A warming-up timer starts to countdown from 90 sec. Then, the inhibition is released. MultiXplo / MultiTox Page 44 / 60 NOSP15759-Rev 10...
If the detection unit or the PLC signals a detector’s fault, the detector must be tested directly with the wireless communication tool to determine the type of fault. If the detector is configured in 0-22 mA output, it is possible to have a pre-diagnostic of the fault. MultiXplo / MultiTox Page 45 / 60 NOSP15759-Rev 10...
Check that the green LED flashes. wireless communication tool Check the wireless communication tool by using Dialogue problem connection it on another detector. Detector fault Electronic fault Replace the detector (Material fault) MultiXplo / MultiTox Page 46 / 60 NOSP15759-Rev 10...
As the base of the detector remains in place, cable glands do not need to be dismantled. If the detector is not replaced immediately, the “open” base must be protected against humidity, dust and shocks No intervention should be carried out when the detector is powered. MultiXplo / MultiTox Page 47 / 60 NOSP15759-Rev 10...
* IP rating does not mean that the equipment will detect the gas during or after exposure to the defined conditions. It is also recommended to use the device with the following accessories: AS056-250, AS019, AS015. MultiXplo / MultiTox Page 49 / 60 NOSP15759-Rev 10...
Water, sand and dust Adaptation to all cartridges, the assembly AS019 protection is directly in front of cartridge thanks to the nut of maintain (black on version -A). MultiXplo / MultiTox Page 51 / 60 NOSP15759-Rev 10...
Page 52
Detector sensitivity and response time are not modified. This accessory is included into the EN60079-29-1 Performance Certificate. Wipe non-conductive parts (plastic) that can use in ATEX area with a damp cloth (risk of electrostatic charges) MultiXplo / MultiTox Page 52 / 60 NOSP15759-Rev 10...
Page 54
Special customer (EG) HC lourd F1850 Special customer COCH MTBE H2S + CH4 Hydrogen sulfide Methane Special combustible gas App SA Hydrogen in Argon Complement Argon Hydrogen in Azote Complement Azote MultiXplo / MultiTox Page 54 / 60 NOSP15759-Rev 10...
Page 55
Regarding reference F2 = DG (100% LEL), the following table defines what OLDHAM SIMTRONICS uses of correspondence between %vol and 100% LEL. Nom produit Name of compound Formule % vol équivalent à 100 Formula % LIE / LEL 63DG 1,3-butadiène...
Page 60
EUROPEAN PLANT AND OFFICES Z.I. Est – rue Orfila CS 20417 – 62027 ARRAS Cedex FRANCE Tél.: +33 (0)3 21 60 80 80 – Fax: +33 (0)3 21 60 80 00 Web site: https://teledynegasandflamedetection.com/ AMERICAS ASIA PACIFIC EUROPE Tel : +1-713-559-9280 Tel : +86-21-3127-6373 Tel : +33-321-608-080 Fax : +1-281-292-2860...