  • Page 1 Installation, Operation, and Maintenance Manual 90018601_1.0 CCD 401...
  • Page 3 Notes Notes • The modem is designed to be used with Xylem Cloud Services only and not as a stand- alone modem. • Xylem reserves the right to remotely upgrade the software and configuration files in the modem. It is the Purchaser’s responsibility to ensure that the modem is connected at all times to enable such upgrades.
  • Page 5: Table Of Contents

    3.3 Check the mobile connection..................8 4 Troubleshooting......................... 10 4.1 Symptoms and remedies.....................10 5 Technical Reference......................11 5.1 Dimensions........................11 5.2 Environmental requirements..................11 5.3 Material........................11 5.4 Electrical data......................11 5.5 Radio data........................11 5.6 Terminals........................11 CCD 401 Installation, Operation, and Maintenance Manual...
  • Page 6: Introduction And Safety

    This includes any modification to the equipment or use of parts not provided by Xylem. If there is a question regarding the intended use of the equipment, please contact a Xylem representative before proceeding.
  • Page 7: User Safety

    Risk of electrical shock or burn. A certified electrician must supervise all electrical work. Comply with all local codes and regulations. All work on the product must be carried out by certified electricians or Xylem authorized mechanics. Xylem disclaims all responsibility for work done by untrained, unauthorized personnel.
  • Page 8: Spare Parts

    The use of unsuitable spare parts may cause malfunctions, damage, and injuries as well as void the warranty. 1.6 Warranty For information about warranty, see the sales contract. 1.7 Support Xylem only supports products that have been tested and approved. Xylem does not support unapproved equipment. CCD 401 Installation, Operation, and Maintenance Manual...
  • Page 9: Product Description

    2 Product Description 2.1 Product design CCD 401 is a wireless unit that is used in pumping stations. The unit sends data over the Long Term Evolution (LTE) network with fall-back to the 2G or 3G depending on geography and supported radio standard.
  • Page 10: Installation

    Make sure that the ground (earth) conductor is longer than the phase conductors at both ends of the cable. 3.1.3 Cables These requirements apply for cable installation: CCD 401 Installation, Operation, and Maintenance Manual...
  • Page 11: Antenna

    485 A 485 B Ground (earth) – Connect the two signals leads from the digital switch to the terminals. Digital input is active when connected to GND and it is inactive when open. CCD 401 Installation, Operation, and Maintenance Manual...
  • Page 12: Check The Mobile Connection

    6. Turn on the power of the equipment and if necessary, the separate power supply. 7. Configure the connected devices. For more information, go to the support site at xylem.com/avensor. 3.3 Check the mobile connection The unit is turned on.
  • Page 13 3 Installation The unit must not be disconnected during the connection procedure. CCD 401 Installation, Operation, and Maintenance Manual...
  • Page 14: Troubleshooting

    • Make sure that the equipment is not disconnected from the cloud service. Repeated disconnections can make the reconnection slow. • Check the signal strength and install or move the external antenna to improve the signal strength. CCD 401 Installation, Operation, and Maintenance Manual...
  • Page 15: Technical Reference

    CCD 401 version Network (Frequency/band) CE (European version) LTE Cat 1 bands 3, 7, and 20 GPRS 900/1800 MHz Fallback NA (North America version) LTE Cat 1 bands 2, 4, and 12 5.6 Terminals CCD 401 Installation, Operation, and Maintenance Manual...
  • Page 16 Not used Not used Signal ground Analog input 2, 4-20 mA Analog input 1, 4-20 mA Antenna • SMA connector • Maximum 4 m (13.1 ft) cable • Torque 0.56 Nm (0.41 lb.ft) CCD 401 Installation, Operation, and Maintenance Manual...