Always wear gloves when working with the tool.
•
Always wear ear protection
•
Disposal: Customers should follow local regulations to
handle used/wasted parts
INSTRUCTIONS
1. Drain the coolant from the radiator.
2. Pre-mix the coolant with enough to fill the radiator.
3. Connect the conical adapter to the radiator filler neck.
4. Connect the shop air to the vacuum pump.
5. Connect the coolant hose to the tool's main body, and put the other
end in the container with the pre-mixed coolant.
NOTE: Figure 1 shows how the finished connection looks like.
6. Turn on the air valve to create a vacuum. When the gauge
reaches the range between 20 - 24 inHg, turn the air valve off.
7. Turn on the coolant valve to transfer the coolant into the cooling system.
8. Turn the coolant valve off when the gauge reading is 0 inHg.
9. Disconnect the air line.
10. Remove the tool from the cooling system.
11. Clean the tool prior to storage.
WARNING: This product can expose you to chemicals including Di (2-ethylhexyl) phthalate, lead and lead compounds, which
are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to
www.P65Warnings.ca.gov
Fig. 1
43014-INST