19. VIDEO OUT Level Check
Subject
Color bar chart standard picture frame
Measurement Point
Video output terminal (Terminated at
75
Q)
Measuring Instrument
Oscilloscope
Y level=660
±
40 mV
Specified Value
SYNC level=285
±
20 m V
BURST level=285
±
20 mV
Checking method:
1)
Check that the Y level, SYNC level and BURST level satisfy
the specified values.
Ylevel
SYNC
level
J_
Fig. 7-13.
7-21 E