Meter Setup - A. Menarini Diagnostics GlucoMen areo 2K User Manual

Blood glucose and b-ketone self-monitoring system
Table of Contents

Advertisement

NOTE
● If there are no results in the memory, the screen displays "ooo".
● At the end of reviewing the individual test results, the screen displays
"ooo".
● Keep
or
pressed to speed up the browsing through the results.
● To switch between β-ketone and glucose results memories during
data review, press
for 3 seconds to go back to the "Glu"/"Ket"
memory mode selection.
6.4 Data transmission
Test results stored in the GlucoMen® areo 2K meter's memory can be
also downloaded to GlucoLog® software or apps by means of either
NFC, a dedicated cable, or a Bluetooth dongle distributed by A. Menarini
Diagnostics only.
NOTE
● GlucoLog® software and apps, data cable, and Bluetooth dongles
are supplied separately. See relevant user manuals for instructions on
how to download data.
6.4.1 NFC transmission
For data transmission by means of NFC, the NFC function must be enabled
on the GlucoMen® areo 2K meter (§7.6) and an NFC equipped device
(such as a Smartphone) with GlucoLog® apps.
a. Activate the NFC transmission on the GlucoLog® app of the NFC
equipped device.
b. Bring the GlucoMen® areo 2K NFC antenna close (< 1 cm) to the
antenna of the NFC equipped device.
NOTE
● Data will be transmitted even when the meter is switched off or in
memory recall mode.
c. Data transmission will start automatically (the GlucoMen® areo 2K meter
will turn on and the
blinking icon will be displayed on the screen).
d. After downloading the data, the meter switches off automatically.
WARNING
Data transmission via NFC may decrease battery life.

7. Meter setup

a. Make sure the meter is off (to turn the meter off press
until the screen switches off).
b. Press
for 4 seconds to enter the setup menu.
c. Press
or
to scroll through the setting menus (see pictures below)
and press
to enter each single menu
NOTE
● At anytime during set up, you may either press
strip to perform a test. The changes made so far will be memorized by
the meter.
7.1 Date/Time setup
Use
or
to select the correct value. Press
to the next step: year, month, day, time format (12H, 24H), hour, minutes.
After confirming the minutes (by pressing
(step c §7).
NOTE
● Date is in the DD-MM format.
7.2 Alarm setup
You can set up to six alarms on your GlucoMen® areo 2K meter: three for
glucose test remind, and three for β-Ketone test remind. When the alarm
reaches the set time, the meter sounds for 30 seconds.
a. The display will show the alarm clock and the "Glu" icons, both blinking.
b. The display will show alarm 1 status (the default setting is OFF). You can
c. Press
d. Press
e. Set alarm 2 and 3 by following steps b to d. After you have finished
7.3 Beeper setup
The beeper on your GlucoMen® areo 2K meter is preset to ON. You can
adjust the beeper feature as follows.
a. Press
b. Press
7.4 hypo/hyper alarms setup
Your GlucoMen® areo 2K meter has an alarm feature that allows you to
set your high (hyperglycaemia) and low (hypoglycaemia) blood glucose
thresholds. Based on the values set, the screen will show "hypo" or "hyper",
depending on whether your blood glucose test result is below your low
glucose or above your high glucose threshold values.
for 3 seconds
You can set up the hypo and hyper threshold values as follows:
a. Press
b. Press
c. Press
d. Press
e. Press
f. Press
g. Press
h. Press
7.5 β-Ketone test warning setup
Your GlucoMen® areo 2K blood glucose and β-ketone meter has an
additional warning feature that allows you to set a blood glucose threshold
as a warning for blood β-ketone testing. When the β-ketone test warning
is turned ON, if your blood glucose is above the set threshold, the ketone
to exit, or insert a test
icon will start blinking and an intermittent beep will sound, reminding the
user that a blood β-ketone test would be recommended.
to confirm and move on
) return to the setting menus
You can set up the β-ketone test warning threshold value as follows:
a. Press
b. Press
c. Press
d. Press
5
NOTE
● Press
or insert a test strip to stop the acoustic meter alarm (the
alarm will remain set).
CAUTION
● Before setting the alarms please check that the time is properly set.
Press
or
to scroll between glucose ("Glu" icon blinking) and
β-Ketone ("Ket" icon blinking) alarm section. Press
selection and move on to the next step. In the following steps either
"Glu" or "Ket" icon will be shown, indicating the selected alarm section.
turn it on by pressing
or
. Press
on to the next step.
or
to select the hour. Press
move on to the next step.
or
to select the minutes. Press
move on to the alarm 2 setting.
setting all alarms, press
to return to the setting menus (step c §7).
NOTE
● The alarm will have the format (12H, 24H) set for the time.
● Alarm settings will not be erased when changing the batteries.
or
to turn the beeper ON or OFF.
to confirm and return to the setting menus (step c §7).
WARNING
● Turning off the beeper could mean you miss many important cues
from your meter, such as confirmation or error messages.
WARNING
● Consult your doctor or healthcare provider when setting the Hypo
and Hyper values.
● Do not alter or stop your medication based on this feature, always
consult your doctor or healthcare provider before altering or stopping
medication.
or
to turn the hypo alarm ON/OFF.
to set the hypo alarm value (if ON).
or
to select the desired value. Press and hold either
accelerate the numbering.
to confirm the selection and move on to the hyper alarm setup.
or
to turn the hyper alarm ON/OFF.
to set the hyper alarm value (if ON).
or
to select the desired value. Press and hold either
accelerate the numbering.
to confirm the selection and return to the setting menus (step c
§7).
WARNING
● Consult your doctor or healthcare provider when setting the β-Ketone
test warning value.
● Do not alter or stop your medication based on this feature, always
consult your doctor or healthcare provider before altering or stopping
medication.
or
to turn the β-ketone test warning ON/OFF.
to set the blood glucose threshold value (if β-ketone test
warning is ON).
or
to select the desired value (first setting: 200 mg/dL
(11,1 mmol/L)). Press and hold either
to confirm the selection and return to the setting menus (step c
§7).
to confirm the
to confirm the selection and move
to confirm the selection and
to confirm the selection and
or
to
or
to
or
to accelerate the numbering.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents