LSI LASTEM DNA310.1 User Manual

LSI LASTEM DNA310.1 User Manual

Wind direction sensors

Advertisement

Quick Links

Environmental monitoring solutions
Cod. MW6020
Wind direction sensors
User's manual
Updated 02/10/2020
INSTUM_00222
Page 1/12

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DNA310.1 and is the answer not in the manual?

Questions and answers

Summary of Contents for LSI LASTEM DNA310.1

  • Page 1 Environmental monitoring solutions Cod. MW6020 Wind direction sensors User’s manual Updated 02/10/2020 INSTUM_00222 Page 1/12...
  • Page 2 Wind direction sensors – User’s manual INSTUM_00222 Page 2/12...
  • Page 3: Table Of Contents

    Wind direction sensors – User’s manual Index Description..............................4 Main features ............................ 4 Models and technical specifications ....................4 1.2.1 Standard sensor ......................... 4 1.2.2 Compact sensor ......................... 5 Assembly instructions ..........................5 Mounting standard sensor (DNA31x, DNA81x) ................. 6 Mounting compact sensor (DNA212.1) .....................
  • Page 4: Description

    LSI LASTEM data loggers can identify specific wind alarm conditions and open digital outputs when the wind speed exceeds a certain threshold and the wind direction comes from a defined angle.
  • Page 5: Compact Sensor

    Wind direction sensors – User’s manual 1.2.2 Compact sensor DNA212.1 Wind Principle Magnetic encoder direction Measuring range 0÷360° Threshold 0.4 m/s Accuracy 3° General Output 0÷1 V Information Connector 7 pin IP65 watertight connector Housing Anodized aluminum Power supply 10÷30 Vdc Power consumption 0.4 W EN 6132-1 2013...
  • Page 6: Mounting Standard Sensor (Dna31X, Dna81X)

    Wind direction sensors – User’s manual 2.1 Mounting standard sensor (DNA31x, DNA81x) Unscrew the nut and washer from the shaft thread. Insert the DNA127 wind vane on the sensor’s body. Keep the shank in a steady position and insert the vane until it goes until the nut adjustment.
  • Page 7: Mounting Compact Sensor (Dna212.1)

    Wind direction sensors – User’s manual 2.2 Mounting compact sensor (DNA212.1) Unscrew the screw from the shaft thread. Insert the DNA218 wind vane on the sensor’s body. Take care to centre the wind vane’s notch with the tooth on the sensor body's rotating cone.
  • Page 8: Connections

    Finally, mount the sensor on the mast, orient the red nose to NORTH and tighten the screws (indicated by the arrow). 3 Connections Connections must be performed following the drawings: DNA212.1 DISACC 200006 DNA310.1 DISACC 07032 DNA311.1 DISACC 07046 DNA810 DISACC 07024...
  • Page 9: Maintenance

    Under these conditions, the resistance recorded should be approx. 40 Ω 4.2 Periodic maintenance LSI LASTEM advises don’t leave the sensor in outdoor operation without its rotor/vane. Routine checks should be carried out on the wind direction sensors. • Clean the sensor, attention to the space between the transducer and the cup.
  • Page 10: Accessories / Spare Parts

    Wind direction sensors – User’s manual 5 Accessories / Spare parts 5.1 Sensore DNA212.1 Codice Descrizione DYA046 Coupling bar for WS+WD sensors on ø 45 ÷65 mm pole DWA505 Cable L = 5 m DWA510 Cable L = 10 m DWA525 Cable L = 25 m DWA526...
  • Page 11: Conformity Declarations

    Wind direction sensors – User’s manual 6 Conformity declarations INSTUM_00222 Page 11/12...
  • Page 12 Wind direction sensors – User’s manual INSTUM_00222 Page 12/12...

This manual is also suitable for:

Dna311.1Dna810Dna811Dna814Dna815Dna816 ... Show all

Table of Contents