LSI LASTEM data loggers can identify specific wind alarm conditions and open digital outputs when the wind speed exceeds a certain threshold and the wind direction comes from a defined angle.
Wind direction sensors – User’s manual 1.2.2 Compact sensor DNA212.1 Wind Principle Magnetic encoder direction Measuring range 0÷360° Threshold 0.4 m/s Accuracy 3° General Output 0÷1 V Information Connector 7 pin IP65 watertight connector Housing Anodized aluminum Power supply 10÷30 Vdc Power consumption 0.4 W EN 6132-1 2013...
Wind direction sensors – User’s manual 2.1 Mounting standard sensor (DNA31x, DNA81x) Unscrew the nut and washer from the shaft thread. Insert the DNA127 wind vane on the sensor’s body. Keep the shank in a steady position and insert the vane until it goes until the nut adjustment.
Wind direction sensors – User’s manual 2.2 Mounting compact sensor (DNA212.1) Unscrew the screw from the shaft thread. Insert the DNA218 wind vane on the sensor’s body. Take care to centre the wind vane’s notch with the tooth on the sensor body's rotating cone.
Finally, mount the sensor on the mast, orient the red nose to NORTH and tighten the screws (indicated by the arrow). 3 Connections Connections must be performed following the drawings: DNA212.1 DISACC 200006 DNA310.1 DISACC 07032 DNA311.1 DISACC 07046 DNA810 DISACC 07024...
Under these conditions, the resistance recorded should be approx. 40 Ω 4.2 Periodic maintenance LSI LASTEM advises don’t leave the sensor in outdoor operation without its rotor/vane. Routine checks should be carried out on the wind direction sensors. • Clean the sensor, attention to the space between the transducer and the cup.
Wind direction sensors – User’s manual 5 Accessories / Spare parts 5.1 Sensore DNA212.1 Codice Descrizione DYA046 Coupling bar for WS+WD sensors on ø 45 ÷65 mm pole DWA505 Cable L = 5 m DWA510 Cable L = 10 m DWA525 Cable L = 25 m DWA526...