LOCATING THE TEPPANYAKI GRIDDLE

This gas appliance is designed and certified for outdoor use only. Do not locate this appliance
under unprotected overhead combustible surfaces. When installed under overhead combustible sur-
faces, a certified ventilating hood wider than the appliance shall be installed with a minimum distance
of 36 inches above the cooking surface.
NOTE: Caution should be taken when the Teppanyaki Griddle is used near glass, vinyl siding
or other temperature sensitive construction materials. In some cases it may be necessary to increase
the clearance around the Teppanyaki Griddle to avoid damage to vinyl siding. Check with the manu-
facturer of the siding material for details.
Do not operate the Teppanyaki Griddle inside a building, garage, recreation vehicle or any enclosed
area. When choosing an area, consider exposure to wind, proximity to traffic paths and length of gas
supply line. Keep gas supply lines as short as possible to reduce pressure drop. Keep the Teppa-
nyaki Griddle away from windy area but keep it in a well-ventilated area. Do not obstruct the flow of
combustion and ventilation air around the Teppanyaki Griddle. The supporting edges of the Teppa-
nyaki Griddle must be located level and flat. The counter should also be leveled.
CLEARANCE TO COMBUSTIBLE CONSTRUCTION
A minimum clearance of 12" from the sides and 12" from the back of the grill to adjacent verti-
cal combustible construction must be maintained.
DÉGAGEMENT DE TOUTE CONSTRUCTION COMBUSTIBLE
Il faut maintenir une distance minimum de 12 po (30.48 cm) sur les côtés et de 12 po (30.48 cm) sur
l'arrière du gril par rapport aux constructions combustibles verticales adjacentes.
NON-COMBUSTIBLE ENCLOSURE
The Teppanyaki Griddle must be installed in a NON-COMBUSTIBLE ENCLOSURE ONLY. The
determination of whether a location is combustible or non-combustible construction is made by the
local fire marshal, building inspector or the local safety authority having jurisdiction. If the Teppanyaki
Griddle is to be built into a combustible enclosure, then a Delta Heat Insulation Jacket (DHIJ32) is
REQUIRED. (see page 12)