Advertisement

Quick Links

DELTA HEAT TEPPANYAKI GRIDDLE
INSTALLATION, USE, & CARE MANUAL
MODELS:
DHTG32
P/N: 17634A 02/21

Advertisement

Table of Contents
loading

Summary of Contents for Delta Heat DHTG32

  • Page 1 DELTA HEAT TEPPANYAKI GRIDDLE INSTALLATION, USE, & CARE MANUAL MODELS: DHTG32 P/N: 17634A 02/21...
  • Page 3 IMPORTANT SAFETY INSTRUCTIONS WARNING! Read this manual carefully and completely before using your Teppanyaki Griddle to en- sure proper operation, proper installation, proper servicing and to reduce the risk of fire, burn hazard and/ or other injury. ATTENTION! Lisez attentivement et complètement ce manuel avant d’utiliser votre plaque chauffante Teppanyaki pour assurer un fonctionnement correct, une installation correcte, un entretien approprié...
  • Page 4 A Special Message to our Customers... Congratulations on your purchase of Delta Heat Teppanyaki Griddle. Delta Heat is committed to making outdoor cooking products you’ll be proud to own for years. This manual gives you easy to follow instructions for installing, operating and maintaining your Delta Heat Teppanyaki Griddle.
  • Page 5 Always use caution when operating the Teppanyaki Griddle in a windy area. • The pressure regulator and hose assembly supplied with the Delta Heat Teppanyaki Griddle must be used. Replacement pressure regulators and hose assemblies must be those specified by DELTA HEAT.
  • Page 6: Table Of Contents

    TABLE OF CONTENTS GETTING STARTED GAS SAFETY REQUIREMENTS LP GAS HOOK-UP PORTABLE LP CONNECTION NATURAL GAS INSTALLATION LEAK TEST ELECTRICAL REQUIREMENT WIRING DIAGRAM BURNER FLAME / AIR SHUTTER ADJUSTMENT LOCATING THE TEPPANYAKI GRIDDLE TEPPANYAKI GRIDDLE CUT-OUT DIMENSIONS INSULATION JACKET OPERATING INSTRUCTIONS CLEANING &...
  • Page 7: Getting Started

    LP gas only. The factory supplied regulator and hose must be used with a 20 lb LP cylinder. Do not use any replacement regulator other than that specified by Delta Heat. Natural Gas or NG If the Teppanyaki Griddle is factory built for natural gas, the regulator supplied is set for 4”...
  • Page 8: Gas Safety Requirements

    GAS SAFETY REQUIREMENTS Each appliance is set and tested at the factory for the type of gas supply to be used. Identi- fy the type of gas, either Natural Gas or LP gas and make sure that the marking on the rating/serial plate matches the gas being supplied to the Teppanyaki Griddle.
  • Page 9: Lp Gas Hook-Up

    (7.1 cm²/kg) of stored fuel capacity. The upper edge shall be no more than 5 in (127 mm) above the floor level. iii. every opening shall have a minimum dimension so as to permit the entrance of a 1/8 in (3.2 mm) rod. Delta Heat Service (562) 263-3600 | 3...
  • Page 10: Portable Lp Connection

    PORTABLE LP CONNECTION FOR CART APPLICATIONS An enclosure for an LP gas cylinder shall be ventilated by openings at both the upper and lower levels of the enclosure. The effectiveness of the opening(s) for purposes of ventilation shall be determined with the LP cylinder in place.
  • Page 11 DO NOT STORE SPARE LP GAS CYLINDER UNDER OR NEAR THIS APPLIANCE. NEVER FILL THE CYLINDER BEYOND 80 PERCENT FULL. FAILURE TO DO SO, A FIRE CAUSING DEATH OR SERIOUS INJURY MAY OCCUR Delta Heat Service (562) 263-3600 | 5...
  • Page 12: Natural Gas Installation

    Do not use any replacement regulator other than that specified by DELTA HEAT. Use only pipe sealants that are approved for use with Natural and LP gases. An installer-supplied gas shutoff valve must be installed in an accessible location.
  • Page 13: Leak Test

    Check to ensure that flexible hoses do not have any cuts and wear that may affect the safety before each use. Only the factory supplied hose and regulator must be used. Use only replace- ment regulator and hose assemblies specified by DELTA HEAT. LEAK TEST 1.
  • Page 14: Electrical Requirement

    ELECTRICAL REQUIREMENT TO INSTALL AND SECURE POWER TRANSFORMER The Teppanyaki Griddle is equipped with LED lights that require the use of a power transform- er with an attached power supply cord. This transformer must be secured in a dry location and away from the Teppanyaki Griddle firebox and excessive heat area.
  • Page 15: Wiring Diagram

    WIRING DIAGRAM This Delta Heat product is provided with electrical components, proper handling and care is needed to maintain the quality of your Delta Heat product. 1. To protect against shock, do not immerse cord or plug in water or other liquid;...
  • Page 16: Burner Flame / Air Shutter Adjustment

    BURNER FLAME / AIR SHUTTER ADJUSTMENT Each Teppanyaki Griddle burner is tested and adjusted at the factory prior to shipment; however, vari- ations in the local gas supply may make it necessary to adjust the burners. The flames of the U-burners should be visually checked.
  • Page 17: Locating The Teppanyaki Griddle

    If the Teppanyaki Griddle is to be built into a combustible enclosure, then a Delta Heat Insulation Jacket (DHIJ32) is REQUIRED. (see page 12)
  • Page 18: Teppanyaki Griddle Cut-Out Dimensions

    TEPPANYAKI GRIDDLE CUT-OUT DIMENSIONS THESE DIMENSIONS ARE FOR NON-COMBUSTIBLE CONSTRUCTION ONLY. FOR COMBUSTIBLE CONSTRUCTION SEE NEXT PAGE. 20.50 DHTG32 30.50 19.75 9.50 DETAIL 19.75 WIDTH OF UNIT COUNTERTOP OVERHANG NOTE: DETAIL IS TYPICAL TO ALL DH CUT-OUTS. 12 | www.deltaheat.com...
  • Page 19: Insulation Jacket

    Do not build the grill under overhead combustible construction. If the grill is to be placed into com- bustible enclosure, an approved insulating jacket is necessary to prevent fire, property damage and bodily injury. Use only Delta Heat (DHIJ32) insulating jacket. IMPORTANT If using LP gas cylinder and insulation jacket (DHIJ), use stainless flexible hose to connect LP gas cylinder to grill regulator.
  • Page 20: Operating Instructions

    OPERATING INSTRUCTIONS Lighting Instructions 1. Ensure the Gas supply valve is closed and the burner knob is set to the OFF position. 2. Open the valve on the gas supply. 3. Push and turn the knob counterclockwise to the HIGH position. You will hear the spark igniter come on.
  • Page 21: Cleaning & Maintenance

    304 stainless steel to develop surface oxidation, corrosion or rust. Delta Heat products have been tested in saline solutions, highly chlorinated solutions and have been tested against exposure to highly acidic foods. The test results proved the type 304 stainless steel can withstand exposure over prolonged periods of time.
  • Page 22 WARNING: It is recommended that your Delta Heat products be kept dry and covered when not in use. This is even more important when long-term storage is intended.
  • Page 23 CLEANING & MAINTENANCE - CONT. SPIDER AND INSECT WARNING Spiders and other insects can nest in the burners of this and any other Delta Heat gas ap- pliances, which causes the gas to flow from the front of the burner. This dangerous “condition” can cause a fire behind the valve panel, damaging the gas appliance and making it unsafe to operate.
  • Page 24: Exploded View

    EXPLODED VIEW 18 | www.deltaheat.com...
  • Page 25: Replacement Parts List

    S14232 RETAINING RING S13199 BEZEL S14156 6-32 X .375 SCREW S13195 DELTA HEAT KNOB S13201 DELTA HEAT EMBLEM S16196 12V SWITCH, BLUE S16272 BATTERY PACK S13117 COVER HANDLE S16303 THERMOSTAT S16268Y IR IGNITER Delta Heat Service (562) 263-3600 | 19...
  • Page 26: Warranty

    Delta Heat will repair or replace parts found to be defective at no cost to the original purchaser.
  • Page 27: How To Obtain Service

    HOW TO OBTAIN SERVICE For service, please contact your DELTA HEAT dealer or call DELTA HEAT direct at (562) 263-3600 or (800) 422-0091 or fax (562) 802-3391 Mailing address: DELTA HEAT, Inc. 13259 166th Street Cerritos, CA 90703 Visit us at www.deltaheat.com Please provide: •...
  • Page 28 CUT HERE PLACE POSTAGE HERE Customer Service ATTN: Warranty Department 13259 166th Street Cerritos, CA 90703 Service Direct Line: (562) 263-3600 Fax: (562) 801-3391...

Table of Contents