ACD GENie EC Instruction Manual

ACD GENie EC Instruction Manual

Calibration gas generator

Advertisement

Quick Links

Advanced Calibration Designs, Inc.
GENie EC
GENie QC-1
GENie O3
Calibration Gas Generator
Instruction Manual
Software Rev 1.16

Advertisement

Table of Contents
loading

Summary of Contents for ACD GENie EC

  • Page 1 Advanced Calibration Designs, Inc. GENie EC GENie QC-1 GENie O3 Calibration Gas Generator Instruction Manual Software Rev 1.16...
  • Page 2 Calibration Gas System Instruction Manual for GENie QC-1 GENie EC GENie O3 Software Rev 1.16...
  • Page 3 Calibration Gas System Instruction Manual for GENie QC-1 GENie EC GENie O3 Software Rev 1.16...
  • Page 4: Table Of Contents

    Menu Options: Foreign Language Option ............9 Gas Sources ......................... 9 Accessories and Replacement Parts ..............10 Specifications ......................10 GENie EC Module ......................11 Internal Micro Pump ..................11 Operation ........................11 Menu Options: Sample Draw Mode ..............15 Menu Options: Foreign Language Option ............
  • Page 5: Warning

    Warning This instrument generates calibration gas for toxic gas detectors. The instruction manual should be read and understood before the operation of the instrument. Failure to operate the instrument correctly can lead to improper calibrations. This instrument conforms to the protection requirements of the EC DIRECTIVE 89/336/EEC on Electromagnetic Compatibility (EMC), in accordance with the provisions of Statutory Instrument 2372.
  • Page 6: General Description

    Base Unit General Description The GENie family of instruments consists of the GENie base unit (which provides a microprocessor-based user interface and control system) and a source module (that determines the gas to be generated). GENie Base Unit and GENie (QC-1, EC or O3) Source Module (front and rearview) GENie Base Unit Battery-powered microprocessor-based user interface and control system.
  • Page 7: Microprocessor-Based Circuitry

    Base Unit Continuous operation power adapters are also available for benchtop operation (note adapters are also available for international customers). Microprocessor-Based Circuitry The GENie base unit has microprocessor-based circuitry that performs several different operations and offers the user many different features. The microprocessor tracks source and battery usage, monitors the airflow rate, and controls the source and pump to give the selected ppm and flow rate.
  • Page 8: Mass Flow Sensor

    Base Unit Mass Flow Sensor The GENie main module has a built-in mass flow sensor that measures the flow rate of the instrument. This information is used in two ways. With the pump engaged, it is used to control the pump to the desired flow rate over a range of 0.2 to 1.0 LPM.
  • Page 9 Base Unit Deutsch Español Portuguese Francais Page 5...
  • Page 10: Genie Qc-1 Module

    QC-1 Module GENie QC-1 Module Operation Quick Check Vial (QCV) The GENie QC-1 utilizes the ACD Quick Check Vials (QCVs) as a gas source. Before inserting a new vial into the instrument, open the coarse adjust knob approximately three rotations to allow for easier insertion. To...
  • Page 11 QC-1 Module Calibration Date 01 Jan 2012 The display will change to simply display the concentration as shown below. 100 PPM NH3 Select to change If the instrument is unable to achieve the selected concentration due to insufficient gas concentration, the following screen sequences will display accompanied by an audible beep.
  • Page 12 QC-1 Module When the coarse adjust in range the unit will return to displaying the set point concentration. If the Low PPM warning message is present open the vial adjust slightly by rotating it counterclockwise to allow additional gas to enter the system. If the High PPM warning message is present close the vial adjust knob by rotating it clockwise as shown in the...
  • Page 13: Menu Options: Foreign Language Option

    QC-1 Module 10 to 500 PPM Set ... 100PPM At this point pressing the up or down arrows will result in the output changing accordingly. Pressing the down arrow will scroll the output down from 500 PPM to 10 PPM. When the desired concentration is and return to normal operation displaying the source life and battery status before returning to display the new concentration.
  • Page 14: Accessories And Replacement Parts

    QC-1 Module QCV, Ammonia (NH3), 12 Pack HIGH PPM 525-0011-12 Accessories and Replacement Parts Item Description Part Number EC Module for GENie System 750-0202-01 O3 Module for GENie System 750-0202-02 See page 28 for more Accessories and Replacement Parts. Specifications Airflow rate Variable Useful source life...
  • Page 15: Genie Ec Module

    Operation To start the instrument, press and hold the POWER switch, located in the lower right of the front of the instrument, until the display reads GENie EC, approximately five (5) seconds. Release the switch immediately thereafter. The instrument will sequence through several screens as follows: GENie 1.20...
  • Page 16 EC Module Stabilizing … The unit will then scroll through the flow rate, concentration and gas type, source life, and battery status. Flow 0.5 LPM Select to change 1.00 PPM Source Life Battery Status Note that the gas type will be different depending on the source used as will the source life and concentration ranges.
  • Page 17 EC Module 1.00 PPM At any time during operation, pressing the select switch will result in the following series of menus. Flow 0.5 LPM Select to change 1.00 PPM Select to change Source Life Battery Status When the flow is displayed wi the select button will result in the following display.
  • Page 18 EC Module When the concentration is displa chang pressing the select button will result in the following display. (note that the range may differ depending on the source being used and the flow rate.) 0.5 to 50 PPM At this point pressing the up or down arrows changes the output accordingly.
  • Page 19: Menu Options: Sample Draw Mode

    The unit can now be connected to a sample draw instrument. Do this by connecting the hose from the sample draw instrument to the output of the GENie EC. The GENie will display the flow being pulled through the instrument and wait a short period to ensure the flow is stable. The display will look something like this.
  • Page 20: Menu Options: Foreign Language Option

    To achieve this, simply calibrate the first unit then remove it from the GENie EC. The unit will display the 0 flow and will wait patiently. When the next sample draw instrument is connected the unit will display its flow (they are often slightly different from unit to unit) and will immediately begin producing the concentration set earlier.
  • Page 21: Gas Sources

    EC Module Gas Sources Item Description Capacity PPM Range Part Number (Hrs.) Adjustable (chlorine) micro 10 hr. .05-5 510-0200-15 (chlorine) micro 50 hr. .05-5 510-0200-05 (chlorine) double life micro 100 hr. .05-5 510-0200-25 (chlorine) 10 hr. .5-50 510-0200-10 (chlorine) 50 hr. .5-50 510-0200-00 (chlorine) double life...
  • Page 22: Accessories And Replacement Parts

    EC Module Accessories and Replacement Parts Item Description Part Number QC-1 Module for GENie System 750-0202-03 O3 Module for GENie System 750-0202-02 See page 28 for additional Accessories and Replacement Parts. Specifications Airflow rate (with internal pump 0.2 to 1 LPM Sample draw rate (with pump disabled) 0.1 to 1.2 LPM Source life...
  • Page 23 EC Module button (see arrow) to disengage the source. The source can now be removed. Install the new source by aligning the source contacts and pressing the source in until it stops. Slide the base plate in the opposite direction of the arrows until it snaps in place.
  • Page 24: Genie O3 Module

    O3 Module GENie O3 Module Fast warm-up time allows the instrument to be turned off between remotely located sensors saving battery life and avoiding the generation of unwanted gas. The GENie O3 module uses the following components to produce the calibration gas/air mixture: Internal Micro Pump A small, rotary vane, micro air pump draws in ambient air to blend with the generated gas.
  • Page 25 O3 Module Serial# 000001 Source# 000001 Manufactured 01 Jan 2012 Calibration Date 01 Jan 2012 Initializing… Stabilizing… Standby:60 sec The unit will then scroll through the concentration source life and battery status. 1.00 PPM O3 Select to change Source Life 100 Hrs.
  • Page 26 O3 Module 1.00 PPM O3 Standby:60 sec When the Standby time elapses, the display will change to simply display the concentration as shown below. At this point the calibration gas is stable and you may proceed with calibration. 1.00 PPM O3 Select to change At any time during operation, pressing the select switch will result in the following series of menus.
  • Page 27: Accessories

    O3 Module Menu Options: Foreign Language Option See page 4. Accessories Item Description Part Number QC-1 Module for GENie System 750-0202-03 EC Module for GENie System 750-0202-01 See page 28 for additional Accessories and Replacement Parts. Specifications Ozone (O3) Variable 0.2 to 1.0 PPM Fixed 0.5 LPM 0.2 to 1.6 PPM (0.1...
  • Page 28: Maintenance

    Maintenance Maintenance If the instrument is returned on an annual basis to maintain NIST certification, the charcoal filter will be replaced by the factory. Battery Replacement To access the GENie battery compartment, the base module must be separated from the source module. This is accomplished by slightly pulling down on the base plate to release the latching mechanism and sliding the base plate in the direction of the arrows as shown below.
  • Page 29 Maintenance The source module is now disengaged from the base module and can be pulled away revealing the battery compartment. To re-install the source module onto the base module, take the following steps: Align the air inlet fitting and the locking pins into the eyelet holes as shown.
  • Page 30: Troubleshooting

    If the unit is being operated from the external battery extender, make sure that the power switc accompanied by an audible beep. GENie EC, GENie O3: accompanied by an audible beep. Accurate airflow is critical to an accurate gas mixture.
  • Page 31 Troubleshooting Concentration is unobtainable through the instruments control. Simply open or close the vial adjust knob to correct. If the vial is nearly expired, the vial may need to be replaced with a fresh vial to obtain higher concentrations. Sample draw instruments can be calibrated utilizing the GENie QC-1 by filling a gas bag and drawing the calibration gas from the bag.
  • Page 32: Accessories

    Accessories & Replacement Parts Accessories Item Description QC-1 Part Number GENie EC Module 750-0202-01 GENie QC-1 Module 750-0202-03 GENie O3 Module 750-0202-02 Hard Body Case 730-0615-00 Continuous Operation 362-0000-00 Adapter (specify a country when ordering) External Battery Extender 362-0010-00 (does not include...
  • Page 33: Replacement Parts

    Accessories & Replacement Parts Replacement Parts Item Description QC-1 Part Number Hose, with quick connect, 715-0405-0X External Charcoal Filter 150-0120-00 Assembly, GENie series Hose connector, insert 113-0402-00 (hose barb) quick connect Outlet fitting, body (1/8 113-0400-00 NPT) quick connect Page 29...
  • Page 34: Standard Warranty

    ACD, Inc. including, but not limited to, the warranty of fitness for a particular purpose. In no event shall ACD, Inc. be liable for direct, incidental, or consequential loss or damage of any kind connected with the use of its products or failure of its products to function or operate properly.
  • Page 35 Manufactured by: Advanced Calibration Designs, Inc. 2024 W. McMillan Street Tucson, Arizona 85705 USA Phone: 520 290 2855 . Fax: 520 290 2860 Email: ACD@goacd.com website: www.GoACD.com 910-0202-0X Software Rev 1.16...
  • Page 36 Advanced Calibration Designs, Inc. 2024 W. McMillan St. Tucson, Arizona 85705 USA Telephone: (520) 290-2855 Fax: (520) 290-2860 Toll Free: (800) 737-0223 Email: acd@goACD.com Web: www.goACD.com Software Rev 1.16...
  • Page 37 Base Unit Mass Flow Sensor The GENie main module has a built-in mass flow sensor that measures the flow rate of the instrument. This information is used in two ways. With the pump engaged, it is used to control the pump to the desired flow rate over a range of 0.2 to 1.0 LPM.
  • Page 38 QC-1 Module GENie QC-1 Module Operation Quick Check Vial (QCV) The GENie QC-1 utilizes the ACD Quick Check Vials (QCVs) as a gas source. Before inserting a new vial into the instrument, open the coarse adjust knob approximately three rotations to allow for easier insertion. To...
  • Page 39 QC-1 Module When the coarse adjust in range the unit will return to displaying the set point concentration. If the Low PPM warning message is present open the vial adjust slightly by rotating it counterclockwise to allow additional gas to enter the system. If the High PPM warning message is present close the vial adjust knob by rotating it clockwise as shown in the...
  • Page 40 QC-1 Module 10 to 500 PPM Set ... 100PPM At this point pressing the up or down arrows will result in the output changing accordingly. Pressing the down arrow will scroll the output down from 500 PPM to 10 PPM. When the desired concentration is and return to normal operation displaying the source life and battery status before returning to display the new concentration.
  • Page 41 EC Module 1.00 PPM At any time during operation, pressing the select switch will result in the following series of menus. Flow 0.5 LPM Select to change 1.00 PPM Select to change Source Life Battery Status When the flow is displayed wi the select button will result in the following display.
  • Page 42 EC Module When the concentration is displa chang pressing the select button will result in the following display. (note that the range may differ depending on the source being used and the flow rate.) 0.5 to 50 PPM At this point pressing the up or down arrows changes the output accordingly.
  • Page 43 The unit can now be connected to a sample draw instrument. Do this by connecting the hose from the sample draw instrument to the output of the GENie EC. The GENie will display the flow being pulled through the instrument and wait a short period to ensure the flow is stable. The display will look something like this.
  • Page 44 To achieve this, simply calibrate the first unit then remove it from the GENie EC. The unit will display the 0 flow and will wait patiently. When the next sample draw instrument is connected the unit will display its flow (they are often slightly different from unit to unit) and will immediately begin producing the concentration set earlier.
  • Page 45 EC Module Accessories and Replacement Parts Item Description Part Number QC-1 Module for GENie System 750-0202-03 O3 Module for GENie System 750-0202-02 See page 28 for additional Accessories and Replacement Parts. Specifications Airflow rate (with internal pump 0.2 to 1 LPM Sample draw rate (with pump disabled) 0.1 to 1.2 LPM Source life...
  • Page 46 O3 Module 1.00 PPM O3 Standby:60 sec When the Standby time elapses, the display will change to simply display the concentration as shown below. At this point the calibration gas is stable and you may proceed with calibration. 1.00 PPM O3 Select to change At any time during operation, pressing the select switch will result in the following series of menus.
  • Page 47 If the unit is being operated from the external battery extender, make sure that the power switc accompanied by an audible beep. GENie EC, GENie O3: accompanied by an audible beep. Accurate airflow is critical to an accurate gas mixture.
  • Page 48 Troubleshooting Concentration is unobtainable through the instruments control. Simply open or close the vial adjust knob to correct. If the vial is nearly expired, the vial may need to be replaced with a fresh vial to obtain higher concentrations. Sample draw instruments can be calibrated utilizing the GENie QC-1 by filling a gas bag and drawing the calibration gas from the bag.
  • Page 49 Accessories & Replacement Parts Accessories Item Description QC-1 Part Number GENie EC Module 750-0202-01 GENie QC-1 Module 750-0202-03 GENie O3 Module 750-0202-02 Hard Body Case 730-0615-00 Continuous Operation 362-0000-00 Adapter (specify a country when ordering) External Battery Extender 362-0010-00 (does not include...
  • Page 50 Accessories & Replacement Parts Replacement Parts Item Description QC-1 Part Number Hose, with quick connect, 715-0405-0X External Charcoal Filter 150-0120-00 Assembly, GENie series Hose connector, insert 113-0402-00 (hose barb) quick connect Outlet fitting, body (1/8 113-0400-00 NPT) quick connect Page 29...
  • Page 51 ACD, Inc. including, but not limited to, the warranty of fitness for a particular purpose. In no event shall ACD, Inc. be liable for direct, incidental, or consequential loss or damage of any kind connected with the use of its products or failure of its products to function or operate properly.
  • Page 52 Manufactured by: Advanced Calibration Designs, Inc. 2024 W. McMillan Street Tucson, Arizona 85705 USA Phone: 520 290 2855 . Fax: 520 290 2860 Email: ACD@goacd.com website: www.GoACD.com 910-0202-0X Software Rev 1.16...

This manual is also suitable for:

Genie qc-1Genie o3

Table of Contents