Download Print this page
ICON FIRES Classic User Manual

ICON FIRES Classic User Manual

Double sided firebox

Advertisement

Quick Links

Double Sided Firebox User Manual
1

Advertisement

loading

Summary of Contents for ICON FIRES Classic

  • Page 1 Double Sided Firebox User Manual...
  • Page 2 Operating Manual Thank you for purchasing this Icon Fires Burner. Icon Fires is very safety conscious and we have taken every care in designing, manufacturing and assembling your Icon Fires Burner to ensure it operates effectively, efficiently and safely. In return we ask that you exercise care when using this product and follow the instructions below. Before using your Icon Fires Burner, please read all the information contained in this operation manual carefully.
  • Page 3 CONTENT OF PACKAGING DOUBLE SIDED FIREBOX: • Base Plate - qty 1 • Side Plates - qty 2 • Top Plate - qty 1 • Fascia Assemblies - qty 2 (Packaged separately) • Bolts and Washers - qty varies for each model size Wall Box Top Plate Fascia Assembly Wall Box Side Plate...
  • Page 4 B = Fascia F = Overall G = Fuel Tank Size Burners *Opening *Opening Cut-out Width Height Depth Clearance Width Height Depth Classic & 900mm 600mm 880mm 567mm 450mm 500mm 600mm MB614 Grand XL & 1100mm 600mm 1080mm 567mm 450mm...
  • Page 5 2 - Assembly Instructions - Double Sided Place the base plate flat and fix the side plates to the base plate with the fasteners and washers provided. Do not tighten the fasteners completely. Hand fasten only as you might need to make a positioning and adjustments when the other plates are attached. Lastly fasten the top plate to the side plates.
  • Page 6: Read Carefully

    READ CAREFULLY • The Firebox body that sits inside the wall cavity must be insulated with a layer of insulation material such as rock wool or ceramic blanket that can handle continuous exposure of 300 ℃. The entire Firebox body must be isolated from any combustible material inside the wall cavity. The insulation must be securely fixed onto the body of the Firebox.
  • Page 7 3 - Location, Positioning & Precautions cutout width wall box overall size Typical framework Typical timber framework as an example as an example NB... There must be a minimum of 13mm clearance from anything, all around the Wall Box. Wall surface material Diamond shaped lines indicate Sectional Top View - Double Sided thermal insulation.
  • Page 8: Installation Procedure

    4 - Installation Procedure Always use a certified builder or installation specialist when installing your Firebox. Use only fire rated materials which adhere to the relevant laws and building regulations in the country where the installation is to occur and make sure that spacing tolerances are always adhered to and that the correct insulation materials has been used.
  • Page 9 Step 2: Insert the Wall Box into the opening. Ensure the Firebox is level both horizontally and vertically before placing the Burner inside the Firebox base cut out. Remember to leave adequate space for the Burner to drop down into the void below the Firebox. Wrap the Firebox with the thermal insulation material before inserting into the wall cavity.
  • Page 10 1. All warranty claims are subject to manufacturer’s review and acceptance. 2. Icon Fires warrants that it uses reasonable care and skill to ensure that its products are of reasonable quality. Icon Fires will at it's cost and in it's sole discretion: (i) remedy any defect or fault in any product purchased;...
  • Page 11 QC Checklist Components Base plate 1 of …..……..…..…..……………... Side plates 2 of .……….......... Back plate 1 of (Single Sided only).………………. Top plate 1 of ...……………………………………… Screws and washers Enough for relative model Checked by…………………………………………. www.iconfires.com...

This manual is also suitable for: