2. Set dome address (Figure 14).
Recessed at top of housing and eyeball
assembly are three rotary address switches.
Protocol address ranges are shown below.
Set switches from most significant bit (MSB) to
least significant bit (LSB). For example: For
address 166, set SW3 to 1, SW2 to 6, and
SW1 to 6.
Protocol
Address Range
SensorNet
1–255
Manchester
1–64
RS422
1–99
Figure 14. Setting address switches
SW3
SW2
MSB
0
9 0
3. Connect housing and eyeball assembly to
base (Figure 15).
a. Align recessed dimple on cap of dome with
logo visible on environmental PC board.
b. Mate housing and eyeball assembly to base
and turn it clockwise until you hear a click.
After 10 seconds, dome begins its homing
routine and heater fans are on. This
indicates that address was placed into
dome memory.
!
WARNING!
Heater fans must be working!
If either or both fans are off, dome
could overheat.
AD DELTADOME OUTDOOR HOUSING
8000-2616-04, Rev. B
SW1
LSB
9 0
9
Figure 15. Attaching dome to base in outdoor
housing
Dimple
INSTALLATION AND SERVICE GUIDE
11