STEP 5:
Install Plastic Tubing for Water Supply Line From System Head Outlet to Faucet
1. Determine the length of tubing necessary to connect the system head outlet to the threaded faucet stem
making sure to allow enough tubing to prevent kinking in the line.
2. Check the tubing to be square on both ends ensuring no jagged edges. If necessary, cut ends of tubing to
be square with no jagged edges, as this can cause inappropriate seal of tubing in collet inlet/outlet ports.
3. Without bending or crimping the tubing, wet one end of the tubing with water and push it into the system
head outlet until it stops.
4. Gently slide the compression nut down (thread side up) over the tubing. Making sure the ferrule is in the proper
position with the larger opening on the bottom (going into the nut), install ferrule over the tubing. Place the plastic
insert into the end of the tubing.
5. Firmly push the tubing into the end of the threaded faucet stem hand-tightening the plastic compression
nut onto the threads. Tighten approximately ½ turn with an adjustable wrench.
STEP 6:
1.
2.
3.
To Flush The Cartridges:
1. Turn on the cold water shut-off valve under the sink.
2. Install TLR-A3502 cartridge 2 in Stage 2.
3. Install TLR-A3502 cartridge 1 in Stage 3.
4. Flush the TLR-A3502 cartridges for (5) minutes,
with Stage 1 empty, by running the new faucet for
filtered water. Flushing configuration shown on right.
5. Remove TLR-A3502 cartridge 1 from Stage 3
and install it in Stage 1.
6. Install Hollow Fiber Membrane cartridge
(TLR-A5HF12) in Stage 3. All labels should
be facing front when completed.
Stage 1
Stage 2
Twist-Lock Carbon Block Cartridges (TLR-A3502) Flushing And Installation Instructions
Prior to installing each TLR-A3502 cartridge in its position, we need to perform
a flushing step in order for the filter system to flush out any air and carbon fines
(fine black powder from each cartridge).
To Install A Cartridge:
1. Hold each cartridge with the front label facing a quarter turn to the left.
2. Lift each cartridge straight up into the system head until the two nozzles
seat into the ports and the two extended flanges on top of cartridge are
fully engaged into the system head. Turn the cartridge a quarter turn right
until it stops into the locked position.
Note: When viewing the system from the front,
the Carbon Block cartridges should be positioned
on the left and in the center. The Hollow Fiber
Membrane should be positioned on the right.
Stage 3
Stage 2
Stage 3
3
C1

Advertisement

loading