130A/160A/180A/200A/250A INVERTER MMA DC WELDING MACHINE
● Do not wrap cable around your body while welding.
Noise can damage hearing.
Noise from some processes or equipment can damage hearing.
● Wear approved ear protection if noise level is high.
Extension cables
Using extension cables is not recommended. The use of extension cables will cause voltage to drop. If
an extension cable must be used, be sure it is:
A 3-wire extension cable that has a 3-blade grounding plug, and a 3-slot receptacle that will accept
the plug on the product.
In good condition.
The section of the cable should be bigger to reduce the lower of the cable voltage.

GROUNDING INSTRUCTIONS

This welding machine should be grounded while in use to protect the operator from electric shock. The
welding machine is equipped with a three-core cable and grounding type plug to fit the proper
grounding type receptacle. The
Never connect the green and yellow

IMPORTANT NOTE

Be sure the supply is the same as the voltage and frequency given on the rating plate.
Remove the main plug from socket before carrying out any adjustment or servicing.
green and yellow
or gree n conductor in the cable is the grounding wire.
or green wire to a live terminal.