The thermostat is pre-set and locked at the factory. When locked the keypad is disabled
and changes to the settings cannot be made. To change the settings the lockout switch
must be placed in the unlock position.
To access the lockout switch:
1. Switch off the power.
2. Remove the four screws and cover.
3. Slide the lockout switch to the right to the unlock position.
4. Replace the cover.
5. Re-power the system.
6. To program refer to table below.
Step
Display
1
F or C
2
S1 (blinking)
3
DIF 1 (blinking)
4
C1 / H1
Note: Pressing the set key accepts the setting and brings you to the next step. You must
push the set key through all steps to return to the temperature display to allow the
compressor to operate.

Bait Freezer Thermostat Operation

Description
Fahrenheit or Celsius Scale
Press the set key once to access the Fahrenheit / Celsius scale. The
display will show the current status, either F for degrees Fahrenheit or
C for degrees Celsius. The thermostat has been pre-set at the factory
for Fahrenheit. Press the up or down arrow key to choose between the
F and C.
Setpoint Temperature
Press the set key again to access the setpoint. The display will show
the current set point. The setpoint has been pre-set to 0 degrees F.
Press either the up or down arrow key to change the setpoint to the
desired temperature.
Differential Temperature
Press the set key again to access the differential. The display will show
the current differential. The differential temperature has been pre-set at
5 degrees F. Press either the up or down arrow key to increase or
decrease the differential setting.
Cooling or Heating Mode
Press the set key again to access the heating or cooling mode. The
display will show the current mode. C1 for cooling or H1 for heating.
The Thermostat has been pre-set for C1. Do not change this setting.
The BF does not work in heat mode. Press the set key once more and
programming is complete.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Bait Freezer and is the answer not in the manual?

Questions and answers

Summary of Contents for Sea Frost Bait Freezer

  • Page 1 Bait Freezer Thermostat Operation The thermostat is pre-set and locked at the factory. When locked the keypad is disabled and changes to the settings cannot be made. To change the settings the lockout switch must be placed in the unlock position.
  • Page 2 TROUBLESHOOTING ERROR MESSAGES Appears when either the up or down arrow key is pressed when not in the programming mode. To correct: If the E1 message appears even when no keys are being pressed, replace the control. Appears if the control settings are not properly stored in memory. To correct: Check all settings and correct if necessary.

Table of Contents