Page 1
KNOW YOUR PRODUCT COMPRESSOR • 2.5HP, 50L TANK • 120L/MIN FREE AIR DELIVERY • DUAL PRESSURE GAUGES • 10 BAR PRESSURE • 2 AIR OUTLETS ORIGINAL INSTRUCTIONS WARNING: Read all safety warnings and instructions before use. Failure to follow the warnings and instructions may result in electric shock, fire and/or serious injury. Save these instructions for future reference. 0916...
INTRODUCTION Congratulations on purchasing your Full Boar Air Compressor. The Full Boar Air Compressor provides you with a wide range of options while combining solid performance output. The air compressor delivers an high efficient flow rate and is ideal for applications up to 10 bar.
Page 6
GENERAL POWER TOOL SAFETY WARNINGS WARNING! Read all instructions. Failure to follow all instructions listed below may result in electric shock, fire and/or serious injury. The term “Power Tool” in all of the warnings listed below refers to your mains operated (corded) power tool or battery operated (cordless) power tool.
Page 7
GENERAL POWER TOOL SAFETY WARNINGS (cont.) d. Remove any adjusting key or wrench before turning the power tool on. A wrench or a key left attached to a rotating part of the power tool may result in personal injury. e. Do not overreach. Keep proper footing and balance at all times. This enables better control of the power tool in unexpected situations.
Page 8
AIR COMPRESSOR SAFETY WARNINGS This appliance is not intended for use by young or infirm persons unless supervised by a responsible person to ensure that they can use the appliance safely. Young children should be supervised to ensure that they do not play with the appliance. WARNING! Before connecting a tool to a power source (mains switch power point receptacle, outlet, etc.) be sure that the voltage supply is the same as that specified on the nameplate of the tool.
Page 9
AIR COMPRESSOR SAFETY WARNINGS (cont.) • Be certain to read all the labels on the containers of paint or other materials to be sprayed. Closely follow all safety instructions. Use a respirator mask if there is a chance that you might otherwise inhale the spray material. Carefully check the effectiveness of any respirator mask you intend using.
PRE-SETUP CHECKS • Examine the machine for signs of transit damage. If damaged, do not use, return to place of purchase • The compressor should be set up near the user. • Avoid long air lines and long supply lines (extensions). •...
Page 11
ASSEMBLY (cont.) 4. Insert the axle bolt through the hole in the wheel bracket on the underside of the tank (Fig. 4). Fig. 4 5. From the inside of the wheel bracket, place a flat washer, then a spring washer onto the axle bolt. Fasten the wheel bolt in position with a nut (nuts and washers supplied) (Fig.
Page 12
ASSEMBLY (cont.) Fitting the transport handle 1. Return the compressor to an upright position (Fig. 11). 2. With the hex key supplied (22), loosen the 2 grub screws on both transport Fig. 11 Fig. 12 handle fixtures (20) (Fig. 12). 3.
PREPARATION Filling with oil WARNING! The air compressor must be filled with oil before first use. Recommended lubricating oil: SAE 5W/40 or an alternative of the same quality. On the market also a special compressor oil with the oil type name: L-DAB-46-A is available. Do not mix up different oils when refilling.
OPERATION WARNING! The air compressor must be used with a residual current device with a rated residual current of 30mA or less. Switching on/off 1. Plug the electrical cord into the power point and turn on (Fig. 21). Fig. 21 Fig.
Page 15
OPERATION Unregulated quick lock coupling Air tools can also be attached to the unregulated quick lock coupling (14) (Fig. 26), but the output pressure level may fluctuate. Fig. 26 Overload switch The motor is fitted with an overload switch (17). If the compressor overloads, the overload switch turns off the equipment automatically to protect the compressor.
TROUBLESHOOTING Problem Cause Solution The compressor 1. No supply voltage 1. Check the supply voltage, does not start the power plug and the socket-outlet. 2. Insufficient supply voltage 2. Make sure that the extension cable is not too long and is of suitable current capacity..
MAINTENANCE IMPORTANT! Before cleaning your air compressor or carrying out any maintenance procedure, make sure that the motor is off and the tool disconnected from the power supply to prevent accidental starting. IMPORTANT! Wait until the compressor has completely cooled down. Risk of burns! Checking the safety valve 1.
Page 18
MAINTENANCE (cont.) IMPORTANT! Always depressurise the tank before carrying out any cleaning and maintenance work. Cleaning • Keep the devices free of dirt and dust as far as possible. Wipe the equipment with a clean cloth or blow it with compressed air at low pressure. •...
Page 19
MAINTENANCE (cont.) Changing the oil Recommended lubricating oil: SAE 5W/40 or an alternative of the same quality. The compressor should be refilled for the first time after 100 hours of operation. Thereafter the oil should be drained and refilled after every 500 hours in service. 1.
DESCRIPTION OF SYMBOLS Volts Hertz Alternating current Watts Revolutions or No load speed minø reciprocation per minute Warning Wear eye protection Read instruction manual Wear hearing protection Beware of electrical voltage Sound power level Beware of hot parts Ingress protection from water Litres lP20 Before using for the first time, check the oil level...
CONTENTS 1 x FBT-5100U Air Compressor 1 x Intake Air Filter 2 x Wheels 2 x Feet 1 x Transport Handle 1 x Oil Sealing Plug 2 x Wheel Caps 4 x Grub Screws (for fitting the handle) 1 x Hex Key...
WARRANTY All of our products undergo strict quality checks to ensure that they reach you in perfect condition. In the unlikely event that your device develops a fault, please contact our service department at the address shown on this guarantee card. You can also contact us by telephone using the customer service number shown.
Need help?
Do you have a question about the FBT-5100U and is the answer not in the manual?