Summary of Contents for goSilver Plus

  • Page 1 Manual goSilver Plus / Plus 8...
  • Page 3: Table Of Contents

    Content 01 Foreword Page 4 02 Operation Page 5 03 Selection menu Page 6 04 Setting options Page 7 05 Start of electrolysis Page 9 06 Status screen Page 10 07 Final screen Page 13 08 Production Page 14 09 Notes Page 18 10 Contact Page 19...
  • Page 4: Foreword

    01 Foreword Thank you very much for choosing the goSilver Plus for your own production of colloidal silver. The software together with the TRUEppm® technology - taking into account all the additional factors - fully automatically ensures a consistently high quality of production.
  • Page 5: Operation

    Please familiarize yourself with the ope- ration of the goSilver Plus before the first production. To do this, plug the power plug The rotary switch can be rotated in both into a power outlet and connect USB cable directions and / or pressed down.
  • Page 6: Selection Menu

    03 Selection menu By turning the rotary knob you can navigate through the selection menu or, after fixing a selection, you can specify the corresponding value. After the start screen, the selection menu appears automatically. The arrow (cursor) is in the line „go!“. If the adjusted values fit, you can start the electrolysis directly.
  • Page 7: Setting Options

    04 Setting options want to change. By pressing, the value can be edited - the value now flashes. By turning, the desired value can now be set and fixed by pressing it again. Further details under „04 settings options“. 04.1 Liters You can set amounts of water between 0.1 Liters 1,000...
  • Page 8 04.5 Language — German / English > Water cold You can change the operating language of your goSilver Plus to German or English. 04.3 Water — warm oder cold The change comes into effect after fixing the setting. You can configure the device for production with cold or hot water.
  • Page 9: Start Of Electrolysis

    05 Start of electrolysis After reviewing all settings, you will not need to return to this screen until you wish to make a change in the future. All settings are Press ‚go!‘ To start production with all set permanently saved (even after switching off the device).
  • Page 10: Status Screen

    06 Status screen Water ok! During the manufacturing process, the most important settings are displayed and additional information can be used to mo- nitor the progress of the electrolysis. If you want to make Colloidal silber with hot Liters 0,25 water (90 °...
  • Page 11 ted mg / L are displayed. 06.4 Progress bar The progress of the electrolysis is also 06.3 Remaining time indicated visually as a progress bar. The expected remaining time is display- ed dynamically in hours and minutes. 06.5 Expert Mode At the start, the software calculates the By turning the rotary knob during producti- remaining time with an assumed average...
  • Page 12 06.6 Polarity reversal The goSilver Plus changes the polarity of the electrodes approximately every 15 seconds. This prevents excessive formati- on of electrode sludge and possibly short circuits between the electrodes. The electrodes do not need to be cleaned during manufacture. The flawless function...
  • Page 13: Final Screen

    0:05h Note: The goSilver Plus switches to standby mode at the end of production and remains ready for further production. Accordingly, the goSilver Plus does not turn itself off. If desired, disconnect the device from the USB power adapter.
  • Page 14: Production

    08 Production ver Plus 8 you can connect one, two, three or four pairs. The device recognizes the number of electrodes and includes this in the calculation of the production time. Please pour distilled water, preferably „Ampuwa for Dishwashing“ into a glass jar.
  • Page 15 The distance between the surface of the water and the adapters should be about 5mm, in a production with permanent 90 ° C about 10mm. Pair 1 Pair 2 Pair 3 Pair 4 Illustration only applies to the goSilver Plus 8...
  • Page 16 After you have previously made your desired settings on the goSilver Plus, start the electrolysis process. After a successful water test, goSilver Plus starts and the display changes to the status display.
  • Page 17 When the desired concentration is rea- ched, the device automatically switches to standby mode. Depending on the setting, a beep sounds and the final screen is shown in the display. After use, wipe the silver electrodes while still wet with a dry cloth. If you have produced Ionian Silver with cold water, please protect the suspension from direct sunlight and seal it airtight in a...
  • Page 18: Notes

    (www.gosilver.de/shop). please never set the same number in milligrams per liter (mg / L) in goSilver Plus. That would be 10 times the recommended dose. Further information on this topic can be found at www.gosilver.de/trueppm-en...
  • Page 19: Contact