Ðóñ SMART 1000/1500/2000/3000 9. РЕШЕНИЕ ВОЗМОЖНЫХ ПРОБЛЕМ Проблема Причина Решение ИБП не включается или не выключа 1. Кнопка ВКЛ/ВЫКЛ не нажата. 1. Нажмите ещe раз. ется. 2. Короткое замыкание на выходе 2. Отключите часть нагрузки. или произошло отключение из за перегрузки.
ÈÍÑÒÐÓÊÖÈß ÏÎ ÝÊÑÏËÓÀÒÀÖÈÈ 10. ТЕХНИЧЕСКИЕ ХАРАКТЕРИСТИКИ Параметры/Модели Smart 1000 Smart 1500 Smart 2000 Smart 3000 Максимальная нагрузка 1000 ВА /600 Вт 1500 ВА /900 Вт 2000 ВА/1200 Вт 3000 ВА/1800 Вт Процессор На основе RISC микропроцессора Действующее напряжение на входе и выходе, частота, выходная мощность, Контролируемые...
Page 11
SMART 1000/1500/2000/3000 Line Interactive Uninterruptible Power System POWER SMART 1000 POWER SMART 1500 POWER SMART 2000 POWER SMART 3000 Please read this operation manual before using the unit and retain this operation manual in safe place for future reference.
Page 12
USER’S MANUAL Thanks for your purchasing the Sven Smart UPS product. Please read the USER’S MAN UAL before using the Sven Smart UPS product. INFORMATION TO USER Changes or modifications to this equipment not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
SMART 1000/1500/2000/3000 1. INTRODUCTION The UPS are an extremely reliable standby Uninterruptible Power System designed to keep computers and peripheral devices such as com- puter, storage subsystems, fax machines, modems, etc performing from the utility power failure which could result in damage of data. In the event of utility failure, the UPS supplies power to your equipment derived from a battery within the UPS and provides visual and audi- ble indicators which alert you to utility line failures, therefore, the user has ample time to save file and close operations.
USER’S MANUAL 6. CONTROLS AND INDICATORS 6.1 Front panel explanations – Utility LED – Fault LED – On Switch LINE – UPS – LOAD – Off Switch – Battery Replacement LED – Battery Backup LED g Screw for Easy Swappable Battery Cover –...
SMART 1000/1500/2000/3000 7. INSTALLATION 7.1. Connect the Loads First, connect the UPS with Utility, then plug the loads into the outlets on the rear of the UPS. To use the UPS as a master On/Off switch, make sure that all of the loads are switch On. These UPS outlets provide battery power and surge protection to the equipment when utility voltage is outside acceptable limits.
USER’S MANUAL 7.7. Test Under Utility Normal condition, push the “On” Switch for 3 seconds to execute the Battery Self-test function. In case the battery is normal, it will enter into Battery Backup Mode for 10 seconds then return back to Utility Mode. If the battery voltage is detected lower than set limit, the Battery Replacement LED will blink for 5 seconds then extinguish to stop self-test procedure.
SMART 1000/1500/2000/3000 9. TROUBLESHOOTING Situation Check items Solution Mains normal but 'Line' LED is not on Is the power switch on? Press Main Switch on Is the fuse in order? Change fuse with same rating Is the power cord loose? Re connect the power cord properly 'Inverter' LED flashes every 2 second Battery voltage is too low...