Troubleshooting Guide - Prestan PP-IM-100M Use And Care Instructions Manual

Infant manikin
Hide thumbs Also See for PP-IM-100M:

Advertisement

SYMPTOM
CPR Rate Monitor
Cannot find CPR Rate
Monitor (Monitor) – no
lights in the diaper area
CPR Rate Monitor
(Monitor) lights are not
working properly
Please follow the
troubleshooting tips at
right in the order they are
listed for best results
CPR Rate Monitor
(Monitor) lights are all on
CPR Rate Monitor
(Monitor) red light is
blinking
CPR Rate Monitor falls out
when administering back
blows
* Contact your Prestan Authorized Distributor to either purchase the replacement part or receive it at no charge if the
manikin is within Prestan's 3-year warranty period and is a qualifying warranty repair.
First-Aid-Product.com - 760-944-1048
COPYRIGHT© 2016 PRESTAN PRODUCTS, LLC
Toll Free: (800) 933-8495

TROUBLESHOOTING GUIDE

POSSIBLE ISSUES OR COMMENTS
 You have purchased/received a Prestan
Professional Infant Manikin without the
CPR Rate Monitor
 Chest compressions are not deep
enough to signal Monitor
 Batteries are not installed, need
replacing or are not inserted correctly
in the CPR Rate Monitor
 Either the Clicker or the Monitor needs
to be replaced
 Batteries are running low
 This is normal after replacing batteries
or manikin is paused - may blink up to
16 times to indicate ready status
 Monitor cover in diaper area is no
longer fitting properly
If you were expecting a monitored
manikin, check with the distributor
where you purchased the manikin to
insure you received the item you paid
for. See the chart on page 2 of this
manual for the product numbers.
Note: Infant CPR Rate Monitors may be
purchased separately from your
Prestan Authorized Distributor. They
are shipped with a replacement diaper
area cover for viewing the lights
through it.
Compress the chest until the click is
audible from the Clicker at 2"-2.4"
Install or replace batteries into Monitor
(front of manikin, top of diaper) –
requires 2-AA (1.5V) batteries
Exchange Monitors with working
manikins (if available) to confirm
whether the Monitor
(RPP-IMON-1) needs to be replaced*
Replace batteries
Commence or resume compressions -
blinking will stop and feedback rate
signals will begin
Request new Infant Monitor Cover
(10402)*
7
SOLUTIONS