Table of Contents

Advertisement

PL-300 3.2 I
NSTALLATION AND
C
M
ONFIGURATION
ANUAL

Advertisement

Table of Contents
loading

Summary of Contents for PacketLight Networks PL-300

  • Page 1 PL-300 3.2 I NSTALLATION AND ONFIGURATION ANUAL...
  • Page 2 PacketLight Networks, Ltd. All Rights Reserved. The information shall not be used, copied, reproduced, or disclosed in whole or in part without the written consent of PacketLight Networks, Ltd. PacketLight Networks, Ltd. reserves the right, without prior notice or liability, to make changes in equipment design or specifications.
  • Page 3: Table Of Contents

    ONTENTS 2.3.2 O ..........37 PTICAL ABLE ANDLING RECAUTIONS APPENDIX A: ITU GRID SPECIFICATIONS ............39 DWDM ITU 100 GH ...............39 PACING PL-300 3.2 I ACKET IGHT ETWORKS NSTALLATION AND ONFIGURATION ANUAL ONFIDENTIAL AND ROPRIETARY NFORMATION LL RIGHTS RESERVED AGE I...
  • Page 4 CONTENTS DWDM ITU 50 GH ..............40 PACING CWDM ITU G ..................43 APPENDIX B: PL-300 APPLICATION EXAMPLES ..........45 ....................45 XAMPLES B.1.1 E 1: U PL-300 DWDM-2M-16W-1C-1F.........45 XAMPLE SING B.1.2 E 2: U PL-300 DWDM-2M-8W-1C-2F ........46 XAMPLE SING B.1.3 E 3: U PL-300 CWDM-2M-8W-2C-2F........47...
  • Page 5 CONTENTS List of Figures Figure 1: PL-300 Unit, General View ................ 3 Figure 2: PL-300 CWDM-1M-4W-1C-2F ..............4 Figure 3: PL-300 CWDM-1M-4W-1C-2F-10G .............. 5 Figure 4: PL-300 CWDM-1M-8W-1C-2F ..............5 Figure 5: PL-300 CWDM-1M-16W-1C-2F ..............6 Figure 6: PL-300 CWDM-2M-4W-2C-2F ..............6 Figure 7: PL-300 CWDM-2M-8W-2C-2F ..............
  • Page 6 Table 22: DCM Port Specifications ................36 Table 23: MNG Port Specifications ................37 Table 24: DWDM ITU 100 GHz Grid .................39 Table 25: DWDM 50 GHz ITU Grid ................40 Table 26: CWDM ITU Grid ..................43 PL-300 3.2 I ACKET IGHT ETWORKS NSTALLATION AND...
  • Page 7: Introduction

    Configurations ..................3 Technical Specifications ................. 26 Overview The PL-300 family of products extends PacketLight’s optical network solution capabilities by providing a wide range of passive optical modules. The PL-300 interconnects seamlessly with PacketLight’s products, such as the PL-400E, PL-1000, PL-1000RO, and third-party WDM products to form cost-effective, high-capacity DWDM and CWDM solutions.
  • Page 8: Passive Mux/Demux Modules

    SONET/SDH ADM equipped with colored optics with matching wavelengths. The COM ports of the PL-300 can be connected directly to the line fiber or, in the case of DWDM PL-300, to other PacketLight products, such as PL-1000IL, for amplification of the aggregated optical signal or to the PacketLight ROADM node PL-1000RO.
  • Page 9: Physical Description

    Integrate with third-party CWDM/DWDM optical solutions and colored optics. • Physical Description The PL-300 is a compact 1U unit intended for installation in 19-inch or 23-inch racks or placed on desktops or shelves. All connections are made to the front panel.
  • Page 10: Figure 2: Pl-300 Cwdm-1M-4W-1C-2F

    The MUX/DEMUX module has an additional channel for the management  OSC channel One COM port with dual fiber  Figure 2: PL-300 CWDM-1M-4W-1C-2F 2. PL-300 CWDM-1M-4W-1C-2F-10G: Single passive optical MUX/DEMUX module with four wavelengths  The MUX/DEMUX module has an additional channel for the management ...
  • Page 11: Figure 3: Pl-300 Cwdm-1M-4W-1C-2F-10G

     The four wavelengths match the DWDM ITU grid which allows for 10G  client signals Figure 3: PL-300 CWDM-1M-4W-1C-2F-10G 3. PL-300 CWDM-1M-8W-1C-2F: Single passive optical MUX/DEMUX module with eight wavelengths  The MUX/DEMUX module has an additional channel for the management ...
  • Page 12: Figure 5: Pl-300 Cwdm-1M-16W-1C-2F

    NTRODUCTION One COM port with dual fiber  Figure 5: PL-300 CWDM-1M-16W-1C-2F 5. PL-300 CWDM-2M-4W-2C-2F: Two passive optical MUX/DEMUX modules with four wavelengths each  Each MUX/DEMUX module has an additional channel for the management  OSC channel Two COM ports with dual fiber ...
  • Page 13: Figure 7: Pl-300 Cwdm-2M-8W-2C-2F

    NTRODUCTION Two COM ports with dual fiber  Figure 7: PL-300 CWDM-2M-8W-2C-2F 7. PL-300 CWDM-2M-16W-2C-2F: Two passive optical MUX/DEMUX modules with 16 wavelengths each  Each MUX/DEMUX module has an additional channel for the management  OSC channel PL-300 3.2 I...
  • Page 14: Figure 8: Pl-300 Cwdm-2M-16W-2C-2F

    NTRODUCTION Two COM ports with dual fiber  Figure 8: PL-300 CWDM-2M-16W-2C-2F 8. PL-300 CWDM-1M-8W-1C-1F: Single passive optical MUX/DEMUX module with eight wavelengths  The MUX/DEMUX module has an additional channel for the management  OSC channel One COM port with single fiber ...
  • Page 15: Figure 10: Pl-300 Cwdm-1M-16W-1C-1F

    The MUX/DEMUX module has an additional channel for the management  OSC channel One COM port with single fiber  Figure 10: PL-300 CWDM-1M-16W-1C-1F 10. PL-300 CWDM-2M-8W-2C-1F: Two passive optical MUX/DEMUX modules with eight wavelengths each  Each MUX/DEMUX module has an additional channel for the management ...
  • Page 16: Figure 11: Pl-300 Cwdm-2M-8W-2C-1F

    NTRODUCTION Two COM ports with single fiber  Figure 11: PL-300 CWDM-2M-8W-2C-1F 11. PL-300 CWDM-2M-16W-2C-1F: Two passive optical MUX/DEMUX modules with 16 wavelengths each  Each MUX/DEMUX module has an additional channel for the management  OSC channel PL-300 3.2 I...
  • Page 17: Cwdm Oadm Configurations

    NTRODUCTION Two COM ports with single fiber  Figure 12: PL-300 CWDM-2M-16W-2C-1F 1.5.2 CWDM OADM Configurations The following table lists the PL-300 CWDM OADM configurations. Table 2: CWDM OADM Configurations PL-300 OADM OADM OADM Clients OADM Model Type Ports Fiber...
  • Page 18: Figure 13: Pl-300 Cwdm-1O-4W1470-1C-2F

     Single COM port with dual fiber  Single express (EXP) port with dual fiber  Figure 13: PL-300 CWDM-1O-4W1470-1C-2F 2. PL-300 CWDM-1O-3W1410-2C-2F: Dual OADM module with three Add/Drop wavelengths  The Add/Drop wavelengths are: 1410, 1430 and 1450nm ...
  • Page 19: Dwdm Mux/Demux Configurations

    Two COM ports with dual fiber  Two EXP ports with dual fiber  Figure 14: PL-300 CWDM-1O-3W1410-2C-2F 1.5.3 DWDM MUX/DEMUX Configurations The following table lists the PL-300 DWDM MUX/DEMUX configurations. Table 3: DWDM MUX/DEMUX Configurations PL-300 Clients MUX1 MUX2 MNG1...
  • Page 20: Figure 15: Pl-300 Dwdm-1M-4W-1C-2F

    Single passive optical MUX/DEMUX module with four wavelengths  The MUX/DEMUX module has an additional channel for the management  OSC channel One COM port with dual fiber  Figure 15: PL-300 DWDM-1M-4W-1C-2F PL-300 3.2 I ACKET IGHT ETWORKS NSTALLATION AND ONFIGURATION...
  • Page 21: Figure 16: Pl-300 Dwdm-1M-8W-1C-2F

    The MUX/DEMUX module has an additional channel for the management  OSC channel One COM port with dual fiber  Figure 16: PL-300 DWDM-1M-8W-1C-2F 3. PL-300 DWDM-1M-16W-1C-2F: Single passive optical MUX/DEMUX module with 16 wavelengths  The MUX/DEMUX module has an additional channel for the management ...
  • Page 22: Figure 18: Pl-300 Dwdm-1M-40W-1C-2F

    NTRODUCTION One COM port with dual fiber  Figure 18: PL-300 DWDM-1M-40W-1C-2F 5. PL-300 DWDM-2M-4W-2C-2F: Two passive optical MUX/DEMUX modules with four wavelengths each  Each MUX/DEMUX module has an additional channel for the management  OSC channel Two COM ports with dual fiber ...
  • Page 23: Figure 20: Pl-300 Dwdm-2M-8W-2C-2F

    Each MUX/DEMUX module has an additional channel for the management  OSC channel Two COM ports with dual fiber  Figure 20: PL-300 DWDM-2M-8W-2C-2F 7. PL-300 DWDM-2M-16W-2C-2F: Two passive optical MUX/DEMUX modules with 16 wavelengths each  Each MUX/DEMUX module has an additional channel for the management ...
  • Page 24: Figure 21: Pl-300 Dwdm-2M-16W-2C-2F

    NTRODUCTION Two COM ports with dual fiber  Figure 21: PL-300 DWDM-2M-16W-2C-2F 8. PL-300 DWDM-2M-8W-2C-1F: Two passive optical MUX/DEMUX modules with eight wavelengths each  Each MUX/DEMUX module has an additional channel for the management  OSC channel PL-300 3.2 I...
  • Page 25: Figure 22: Pl-300 Dwdm-2M-8W-2C-1F

    NTRODUCTION Two COM ports with single fiber  Figure 22: PL-300 DWDM-2M-8W-2C-1F 9. PL-300 DWDM-2M-16W-2C-1F: Two passive optical MUX/DEMUX modules with 16 wavelengths each  Each MUX/DEMUX module has an additional channel for the management  OSC channel PL-300 3.2 I...
  • Page 26: Figure 23: Pl-300 Dwdm-2M-16W-2C-1F

    NTRODUCTION Two COM ports with single fiber  Figure 23: PL-300 DWDM-2M-16W-2C-1F 10. PL-300 DWDM-2M-16W-1C-1F (Red/Blue): Two passive optical MUX/DEMUX modules with 16 wavelengths each  Each MUX/DEMUX module has an additional channel for the management  OSC channel Red/Blue band filter ...
  • Page 27: Figure 24: Pl-300 Dwdm-2M-16W-1C-1F (Red/Blue)

    NTRODUCTION One COM port with single fiber  Figure 24: PL-300 DWDM-2M-16W-1C-1F (Red/Blue) 11. PL-300 DWDM-2M-44W-1C-1F-50G (Red/Blue): Two passive optical MUX/DEMUX modules with 44 wavelengths each  Each MUX/DEMUX module has an additional channel for the management  OSC channel Red/Blue band filter ...
  • Page 28: Dwdm Oadm Configurations

    One COM port with single fiber  50 GHz spacing  Unidirectional  Figure 26: PL-300 DWDM-1M-88W-1C-1F-50G-1D (Unidirectional) 1.5.4 DWDM OADM Configurations The following table lists the PL-300 DWDM OADM configurations. Table 4: DWDM OADM Configurations PL-300 OADM OADM OADM Clients OADM Model...
  • Page 29: Figure 27: Pl-300 Dwdm-1O-4W28-1C-2F

    Single OADM module with four Add/Drop wavelengths  Additional 1510 OSC management channel  Single COM port with dual fiber  Single EXP port with dual fiber  Figure 27: PL-300 DWDM-1O-4W28-1C-2F PL-300 3.2 I ACKET IGHT ETWORKS NSTALLATION AND ONFIGURATION ANUAL...
  • Page 30: Dcm Configurations

    Two COM ports with dual fiber  Two EXP ports with dual fiber  Figure 28: PL-300 DWDM-1M-3W28-2C-2F 1.5.5 DCM Configurations The following table lists the PL-300 DCM configurations. Table 5: DCM Configurations PL-300 Model DCM # Distance Up to 40 km DCM1-40K...
  • Page 31: Figure 29: Pl-300 Dcm1

    Single passive optical DCM module  One In/Out port  Supports a distance of up to <n> km  Figure 29: PL-300 DCM1 2. PL-300 DCM2-<n>K: Two passive optical DCM modules  Two In/Out ports  Supports a distance of up to <n> km ...
  • Page 32: Technical Specifications

    Four In/Out port  Supports a distance of up to <n> km  Figure 31: PL-300 DCM4 Technical Specifications This section describes the PL-300 technical specifications. 1.6.1 General Specifications Table 6: General Specifications Number of Ports Up to 44 ports...
  • Page 33: Cwdm Mux/Demux Specifications

    ≥45 ≥45 ≥45 Express Channel Wavelength (nm) 1311+/-30 1311+/-6.5 1291+/-6.5 Express Channel Link Loss (dB) ≤1.5 ≤1.5 ≤1.5 Connector Type LC/UPC LC/UPC LC/UPC PL-300 3.2 I ACKET IGHT ETWORKS NSTALLATION AND ONFIGURATION ANUAL ONFIDENTIAL AND ROPRIETARY NFORMATION LL RIGHTS RESERVED...
  • Page 34: Cwdm Oadm Specifications

    8 Channels 16 Channels 40 Channels DWDM Passband CH28-CH31 CH28-CH35 CH20-CH35 CH20-CH59 (Channels) Channel Spacing (GHz) 100 GHz 100 GHz 100 GHz 100 GHz PL-300 3.2 I ACKET IGHT ETWORKS NSTALLATION AND ONFIGURATION ANUAL ONFIDENTIAL AND ROPRIETARY NFORMATION LL RIGHTS RESERVED...
  • Page 35: Table 11: Dwdm Mux/Demux 100 Ghz Single Fiber Specifications

    Link Loss (MUX+DEMUX) (dB) ≤6 Adjacent Channel Isolation (dB) ≥26 Non-Adjacent Channel Isolation (dB) ≥45 • Express Channel Wavelength (nm) 1511+/-6.5 • 1491+/-6.5 PL-300 3.2 I ACKET IGHT ETWORKS NSTALLATION AND ONFIGURATION ANUAL ONFIDENTIAL AND ROPRIETARY NFORMATION LL RIGHTS RESERVED...
  • Page 36: Table 13: Dwdm Red/Blue Mux/Demux 100 Ghz Single Fiber Specifications

    Express Channel Wavelength (nm) 1491+/-6.5 1511 +/- 6.5 Express Channel Link Loss (dB) ≤1 ≤1 Connector Type Channels LC/UPC LC/UPC Connector Type COM SC/UPC SC/UPC PL-300 3.2 I ACKET IGHT ETWORKS NSTALLATION AND ONFIGURATION ANUAL ONFIDENTIAL AND ROPRIETARY NFORMATION LL RIGHTS RESERVED...
  • Page 37: Dwdm Oadm Specifications

    > 40 GHz < 1.5 dB 220 Km 100 GHz > 30 GHz < 1.5 dB 400 Km 100 GHz > 30 GHz 5.0 dB PL-300 3.2 I ACKET IGHT ETWORKS NSTALLATION AND ONFIGURATION ANUAL ONFIDENTIAL AND ROPRIETARY NFORMATION LL RIGHTS RESERVED...
  • Page 39: Installation

    NSTALLATION Installation This chapter provides installation information and instructions for the PL-300. In this Chapter Safety Precautions ................33 Site Requirements ................34 Installing the PL-300 Unit ..............37 Safety Precautions This section describes the safety precautions. 2.1.1 General Safety Precautions The following are the general safety precautions: •...
  • Page 40: Site Requirements

    Site Requirements This section describes the PL-300 site requirements. 2.2.1 Physical Requirements The PL-300 units are intended for installation in 19-inch or 23-inch racks or placed on desktops or shelves. All the connections are made to the front panel. 2.2.2 Ambient Requirements The following table provides the recommended PL-300 ambient requirements.
  • Page 41: Table 19: Client Port Specifications

    2.2.3.3 EXP Ports The EXP ports can be present only on PL-300 OADM models. The EXP port is used to continue the other channels that were not added or dropped by the OADM. There are two configurations for EXP ports: 1: Single EXP port •...
  • Page 42: Table 21: Exp Port Specifications

    • Configuration 2: Two EXP ports When two OADMs are used, both EXP ports of the PL-300 are available and should be connected to each other. This configuration should be used in a Ring topology or in a linear add/drop topology where new links may be added by nodes along the chain.
  • Page 43: Installing The Pl-300 Unit

    2 mm optical fiber Connector Type Port Type Optical Supervisory Channel Installing the PL-300 Unit PL-300 units are intended for installation in 19-inch or 23-inch racks or placed on desktops or shelves. Before installing a PL-300 unit, review the Safety Precautions AUTION (p.
  • Page 45: Appendix A: Itu Grid Specifications

    1562.23 195.9 1530.33 192.0 1561.42 196.0 1529.55 192.1 1560.61 196.1 1528.77 192.2 1559.79 196.2 1527.99 192.3 1558.98 196.3 1527.22 192.4 1558.17 196.4 1526.44 PL-300 3.2 I ACKET IGHT ETWORKS NSTALLATION AND ONFIGURATION ANUAL ONFIDENTIAL AND ROPRIETARY NFORMATION LL RIGHTS RESERVED...
  • Page 46: Dwdm Itu 50 Ghz Spacing Grid

    193.9 1574.95 1545.72 190.40 1574.54 194.00 1545.32 190.45 194.05 1574.13 1544.92 190.50 1573.71 194.10 1544.53 190.55 1573.30 194.15 1544.13 190.60 1572.89 194.20 1543.73 PL-300 3.2 I ACKET IGHT ETWORKS NSTALLATION AND ONFIGURATION ANUAL ONFIDENTIAL AND ROPRIETARY NFORMATION LL RIGHTS RESERVED...
  • Page 47 1560.61 195.70 1531.90 192.15 195.75 1560.20 1531.51 192.20 1559.79 195.80 1531.12 192.25 1559.39 195.85 1530.72 192.30 1558.98 195.90 1530.33 192.35 195.95 1558.58 1529.94 PL-300 3.2 I ACKET IGHT ETWORKS NSTALLATION AND ONFIGURATION ANUAL ONFIDENTIAL AND ROPRIETARY NFORMATION LL RIGHTS RESERVED...
  • Page 48 1521.79 193.45 1549.72 197.05 1521.40 193.50 1549.32 197.10 1521.02 193.55 197.15 1548.91 1520.63 193.60 1548.51 197.20 1520.25 193.65 1548.11 197.25 1520.25 197.30 1519.48 PL-300 3.2 I ACKET IGHT ETWORKS NSTALLATION AND ONFIGURATION ANUAL ONFIDENTIAL AND ROPRIETARY NFORMATION LL RIGHTS RESERVED...
  • Page 49: Cwdm Itu Grid

    Table 26: CWDM ITU Grid Wavelength (nm) 1271 1291 1311 1331 1351 1371 1391 1411 1431 1451 1471 1491 1511 1531 1551 1571 1591 1611 PL-300 3.2 I ACKET IGHT ETWORKS NSTALLATION AND ONFIGURATION ANUAL ONFIDENTIAL AND ROPRIETARY NFORMATION LL RIGHTS RESERVED...
  • Page 51: Appendix B: Pl-300 Application Examples

    In this example, there are two sites: A and B. Each site has 16 services. The two PL-300 DWDM-2M-16W-1C-1F units are used to combine all of these services on a single fiber. The two additional PL-400E units in each site are used to convert the client signal to DWDM.
  • Page 52: Example 2: Using Pl-300 Dwdm-2M-8W-1C-2F

    In this example, there are two sites: A and B. Each site has eight 10G services. The two PL-300 DWDM-2M-8W-1C-2F units are used to combine all of these services on a dual fiber. The two additional PL-1000 units in each site are used to convert the client signal to DWDM.
  • Page 53: Example 3: Using Pl-300 Cwdm-2M-8W-2C-2F

    In this example, there are two sites: A and B. Each site has eight services of up to 4G. The two PL-300 CWDM-2M-8W-2C-2F units are used to combine all of these services on two protected dual fibers. The two additional PL-400E units in each site are used to convert the client signal to DWDM and duplicate the client signals to Working and Protection.
  • Page 54: Example 4: Using Pl-300 Cwdm-2O-2W1470-2C-2F

    In this example, there is a ring with eight wavelengths. Each site add/drops two protected wavelengths of 10G client signals. The two PL-300 CWDM-2O-2W1470-2C-2F units are used for the two protected wavelengths that arrive from the PL-1000 node to the ring.
  • Page 55: Example 5: Using Pl-300 Dwdm-2M-8W-2C-2F

    B.1.5 Example 5: Using PL-300 DWDM-2M-8W-2C-2F In this example, the PL-300 DWDM-2M-8W-2C-2F is connected on one side to two PL-1000RO nodes, and on the other side to two PL-1000 nodes. The described site is a part of an optical ring. It add/drops four protected wavelengths of 10G clients.
  • Page 56: Example 6: Using Pl-300 Dcm2-120K

    PL-300 DCM2-120K unit. In Site C there is a single PL-400E unit with aggregated eight DWDM channels. Inputs to the two EDFA modules pass through the PL-300 DCM2-120K unit for dispersion compensation. Figure 37: Using PL-300 DCM2-120K (Example) PL-300 3.2 I...
  • Page 57: Appendix C: Pl-300 Fiber Shelf

    In this Appendix Fiber Shelf ................... 51 Fiber Shelf The fiber shelf is an optional tray that can be attached to the PL-300 to help you organize the optical fibers. The following figure illustrates the mechanical details of the fiber shelf.
  • Page 59: Index

    DCM Ports • 36 DWDM-2M-8W-2C-2F • 49 DCM Specifications • 31 Example 6 DWDM ITU 100 GHz Spacing Using PL-300 DCM2-120K • Grid • 39 DWDM ITU 50 GHz Spacing Grid Examples • 45 • 40 Examples of CWDM OADM DWDM MUX/DEMUX Models •...
  • Page 60 General Safety Precautions • 33 Technical Specifications • 26 General Specifications • 26 Typical Applications • 2 Installation • 33 Installing the PL-300 Unit • 37 Introduction • 1 ITU Grid Specifications • 39 Laser Safety Statutory Warning and Operating Precautions • 33 Main Features •...

Table of Contents