Summary of Contents for Synergys LEAKSHOOTER LKS1000 V3+PRO

  • Page 1 USER GUIDE...
  • Page 2: Table Of Contents

    ON / OFF STRAPSHOOTER+ (V3+ PRO) – AUTO ® MAIN MENU MAIN ICONS USED IN LEAKSHOOTER ® K, HOW IT WORKS? K, CONDITION OF USE ACCESSORIES LEAKSHOOTER DETAIL ® — 2 — SYNERGYS TECHNOLOGIES / LEAKSHOOTER ® / User Guide...
  • Page 3: Pack Lks1000 V3+Pro

    PACK LKS1000 V3+PRO — 3 — SYNERGYS TECHNOLOGIES / LEAKSHOOTER ® / User Guide...
  • Page 4: What Is Leakshooter

    (simple round target) or in front of Tightness checking and seal integrity test (with ultrasonic emitter) the leak (round target + cross in its center). — 4 — SYNERGYS TECHNOLOGIES / LEAKSHOOTER ® / User Guide...
  • Page 5 (align RMS real time and MAX). You will see a cross in the If you still have the white target with cross, everywhere, center of the dynamic target. You are in front of the leak. — 5 — SYNERGYS TECHNOLOGIES / LEAKSHOOTER ® / User Guide...
  • Page 6: Detail Of Leakshooter

    DETAIL OF A Thermal camera LEAKSHOOTER ® White LED Visible Camera — 6 — SYNERGYS TECHNOLOGIES / LEAKSHOOTER ® / User Guide...
  • Page 7: Detail Of Keyboard

    SHOOTER+ ON/OFF camera Photo capture Power plug (12V-1.5A) Micro USB plug Wired head phone jack plug Gain setting External probe plug (+or-) Validation or Menu Headphones level setting (+or-) — 7 — SYNERGYS TECHNOLOGIES / LEAKSHOOTER ® / User Guide...
  • Page 8: Detail Of Screen

    Bargraph which is white or colored if K is activated or not Max RMS Real time RMS dB RMS K cursor zone « Large » cursor « Thin » cursor value — 8 — SYNERGYS TECHNOLOGIES / LEAKSHOOTER ® / User Guide...
  • Page 9: Battery Charging

    100% capacity before! Then you will be able to use it after seve- ral months without any problem. — 9 — SYNERGYS TECHNOLOGIES / LEAKSHOOTER ® / User Guide...
  • Page 10: Main Menu

    Memory with leakage photos USB LINK activation General settings K (Severity and Estimator of leak flow/cost) settings Limit of green/white part of bargraph adjustment Bluetooth activation Activation of K function Escape icon — 10 — SYNERGYS TECHNOLOGIES / LEAKSHOOTER ® / User Guide...
  • Page 11 Activation of K function (leak severity or estimation) To set clock/date, luminosity (5 per default), Auto off, frequency mixing (42 kHz per default). Escape icon to go back to measure mode. — 11 — SYNERGYS TECHNOLOGIES / LEAKSHOOTER ® / User Guide...
  • Page 12: K, How It Works

    Only for industrial compressed air (5 to 8 Bar (72 MENU. You can activate or deactivate it according to 116 Psi)). your need. « DISTANCE BETWEEN LEAK AND CONE » SET GAIN TO HAVE CURSOR BETWEEN DOTTED LINES — 12 — SYNERGYS TECHNOLOGIES / LEAKSHOOTER ® / User Guide...
  • Page 13: K, Without Settings

    20-40 ; + Cost/year estimations • 40-60 ; • 3.5 m³/h; • 40-60 ; • 60-80 ; • 14.5 m³/h; • 60-80 ; 80-100 31.7 m³/h) 80-100 • • • — 13 — SYNERGYS TECHNOLOGIES / LEAKSHOOTER ® / User Guide...
  • Page 14: Thermal Camera (V3+Pro) How It Works

    Red cursor and blue cursor values are on the high and low parts of the right vertical colored bargraph. You can access to general settings of IR camera under — 14 — SYNERGYS TECHNOLOGIES / LEAKSHOOTER ® / User Guide...
  • Page 15 THERMAL CAMERA (V3+PRO) HOW IT WORKS? In STRAPSHOOTER+® program Thermal imager Thermal image saved — 15 — SYNERGYS TECHNOLOGIES / LEAKSHOOTER ® / User Guide...
  • Page 16: Strapshooter+ (V3+Pro) How It Works

    (with Enter button on the virtual keyboard). — 16 — SYNERGYS TECHNOLOGIES / LEAKSHOOTER ® / User Guide...
  • Page 17: Strapshooter+ ® (V3+Pro) - Real Time

    Measure T° IN and T° OUT with thermal camera and • save results (SAVE icon • You can save all data following instructions on screen. Note: Blue curve is the REAL TIME ultrasonic noise in the trap. — 17 — SYNERGYS TECHNOLOGIES / LEAKSHOOTER ® / User Guide...
  • Page 18: Strapshooter+ (V3+Pro) - Auto

    If you ESCAPE, program goes back to general STRAPSHOOTER+ ® T°OUT. menu. Click to valid Escape icon to save T°IN and T°OUT values. You can also save thermal picture if necessary or not — 18 — SYNERGYS TECHNOLOGIES / LEAKSHOOTER ® / User Guide...
  • Page 19 It can be BIG LEAK or CLOSED or TOO FAST CYCLING or DROWNED (or NOT IN SERVICE) means trap condition is NOT OK but UNKNOWN. You need to investigate. — 19 — SYNERGYS TECHNOLOGIES / LEAKSHOOTER ® / User Guide...
  • Page 20: Main Icons Used In Leakshooter

    AUTO OFF setting Use # for special non standard money. Frequency mixer setting White LED light ON/OFF (42 kHz per default) Internal or external Clock & date settings probes — 20 — SYNERGYS TECHNOLOGIES / LEAKSHOOTER ® / User Guide...
  • Page 21 FLIR thermal imager (black corner means temperatures T°IN and T°OUT have already been saved)  Temperature unit for thermal camera Scale setting for REAL TIME curve (0-30, 10-40, 20-50, 30-60, 40-70 dB) USB link — 21 — SYNERGYS TECHNOLOGIES / LEAKSHOOTER ® / User Guide...
  • Page 22: Accessories Leakshooter Detail

    ACCESSORIES LEAKSHOOTER ® DETAIL • Flexible 400mm • Flexible 1500mm • Contact probe • 12V external battery • Bluetooth headphones • Bluetooth speaker • Holster • Ultrasonic dome — 22 — SYNERGYS TECHNOLOGIES / LEAKSHOOTER ® / User Guide...
  • Page 24 SYNERGYS TECHNOLOGIES has been established in 1996 in France, USER to offer innovative and professional solutions for preventive and 1000 predictive maintenance. GUIDE SYNERGYS TECHNOLOGIES is the inventor of the ultrasonic  visualization concept with the LEAKSHOOTER , the thermal ®...

This manual is also suitable for:

Leakshooter lks1000-v3-plus-pro