500 People/Minute - 0.3°C Accuracy, 32.8' Max Detection Distance
The IND-MD-TM-CS-TH-KT from Larson Electronics is a Body Temperature Detection Thermal Camera System for active
monitoring at entrance/exit points, buildings, mass transit hubs, public locations and more. A thermal camera and black
body are used to take temperature readings at a rate of 500 people per minute. This system comes with pole/stand
mounting components and network/power cables.
WARNING:
READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
CRITICAL SAFETY INSTRUCTIONS:
INSTALLATION SHOULD ONLY BE CONDUCTED BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH NEC AND ANY
RELEVANT LOCAL BUILDING CODES.
RISK OF FIRE OR ELECTRIC SHOCK. FIXTURE INSTALLATION REQUIRES KNOWLEDGE OF LUMINAIRES ELECTRICAL
SYSTEMS. IF NOT QUALIFIED, CONTACT A QUALIFIED ELECTRICIAN.
BE CERTAIN ELECTRICAL POWER IS OFF BEFORE AND DURING INSTALLATION AND MAINTENANCE.
MAKE SURE THE SUPPLY VOLTAGE IS THE SAME AS THE RATED LUMINAIRE FIXTURES VOLTAGE.
TO PREVENT WIRING DAMAGE OR ABRASION, DO NOT EXPOSE WIRING TO EDGES OF SHEET METAL OR SHARP
OBJECTS. SUITABLE FOR DAMP LOCATIONS.
Infrared Warning
INFRARED LIGHT MAY CAUSE DAMAGE TO EYES IN VERY INTENSE CONCENTRATIONS.
RISK OF EYE DAMAGE AT SHORT DISTANCES. TURN LIGHT SOURCE OFF BEFORE SERVICING.
WIRING
The IND-MD-TM-CS-TH-KT comes with network and power cables. These components can be fed through the poles and
stands during installation.
MOUNTING
The thermal camera and black body are compatible with pole mounting applications (pole mounting components
included). For best results, the thermal camera should be mounted at a height of 7.87' and positioned at an angle of
13°-15°. Optimal height for the black body is 6.88'. The distance between the camera and black body should be 9.84' to
19.68' (optimal distance is 16.4').
Larson Electronics, LLC
Body Temperature Thermal Camera System
Instruction Manual
Phone: (800) 369-6671
Fax: (903) 498-3364
IND-MD-TM-CS-TH-KT
www.larsonelectronics.com
1 of 21

Advertisement

Table of Contents
loading

Summary of Contents for Larson Electronics IND-MD-TM-CS-TH-KT

  • Page 1 INFRARED LIGHT MAY CAUSE DAMAGE TO EYES IN VERY INTENSE CONCENTRATIONS. RISK OF EYE DAMAGE AT SHORT DISTANCES. TURN LIGHT SOURCE OFF BEFORE SERVICING. WIRING The IND-MD-TM-CS-TH-KT comes with network and power cables. These components can be fed through the poles and stands during installation. MOUNTING The thermal camera and black body are compatible with pole mounting applications (pole mounting components included).
  • Page 2: Table Of Contents

    Alarm parameter setting ......................... 14 4.2.1 Black body area setting ........................16 2.2.1 Image registration ..........................18 2.2.1 Image debugging ..........................19 4.2.3 Other settings ............................. 20 4.2.4 Larson Electronics, LLC 2 of 21 Phone: (800) 369-6671 Fax: (903) 498-3364 www.larsonelectronics.com...
  • Page 3: Product Application Site

    1-2. Network hard disk recorder as an optional if video recording is required. Standard: Camera head + stand Black body + stand Switch PC Kit Figure 1-2 Product Configuration Larson Electronics, LLC 3 of 21 Phone: (800) 369-6671 Fax: (903) 498-3364 www.larsonelectronics.com...
  • Page 4: Product Deployment Requirements

    (hats, scarves, sunglasses, masks, antipyretic stickers and other objects that may block the face. It is recommended to remove them in advance and adapt for 0.5-1 minutes carry out testing; Larson Electronics, LLC 4 of 21 Phone: (800) 369-6671 Fax: (903) 498-3364 www.larsonelectronics.com...
  • Page 5 IND-MD-TM-CS-TH-KT Figure 1-3 Product Deployment Larson Electronics, LLC 5 of 21 Phone: (800) 369-6671 Fax: (903) 498-3364 www.larsonelectronics.com...
  • Page 6: Function Introduction

    Figure 2-2 The Main interface can preview visible and infrared images at the same time The real-time temperature of the position can be displayed if you move the mouse cursor to the thermal image in any position. As shown in the figure 2-3. Larson Electronics, LLC 6 of 21 Phone: (800) 369-6671 Fax: (903) 498-3364 www.larsonelectronics.com...
  • Page 7: History" View And Processing Function

    NVR is recording in real time. Once the heartbeat signal of the NVR is not detected, the communication is considered to be interrupted, the heartbeat indicator light is flashing red, and the NVR is not recording. Larson Electronics, LLC 7 of 21 Phone: (800) 369-6671 Fax: (903) 498-3364 www.larsonelectronics.com...
  • Page 8: Settings" System Configuration Function

    Click the "view all history" button in the main interface to enter the history data view interface and view all alarm records, as shown in figure 3-1. Figure 3-1 History record interface Larson Electronics, LLC 8 of 21 Phone: (800) 369-6671 Fax: (903) 498-3364 www.larsonelectronics.com...
  • Page 9: History Record Operation

    IND-MD-TM-CS-TH-KT History record operation Figure 3-2 History record information Larson Electronics, LLC 9 of 21 Phone: (800) 369-6671 Fax: (903) 498-3364 www.larsonelectronics.com...
  • Page 10 (2) click the button at the bottom of the history interface to delete the selected record and classify passengers' heat, low-temperature carry-on items and other carry-on items, as shown in figure 3-5. Figure 3-5 History record processing button Larson Electronics, LLC Phone: (800) 369-6671 Fax: (903) 498-3364 www.larsonelectronics.com...
  • Page 11: Single Group History Record

    Duo record showing Thumbnail of single history record can maximum showing four records, click to showing the rest of the four images. Larson Electronics, LLC Phone: (800) 369-6671 Fax: (903) 498-3364 www.larsonelectronics.com 11 of 21...
  • Page 12: Function Setting

    The setting interface including “Device” and “System”, “System” including alarm settings, shield area, blackbody area, image synchronization, image debugging and other settings. Like Figure 4-2 showing. Figure 4-2 Sub option of system setting Larson Electronics, LLC Phone: (800) 369-6671 Fax: (903) 498-3364 www.larsonelectronics.com...
  • Page 13: Device Management

    Device management interface is as in Figure 4-3. Figure 4-3 Interface of device management Other device list used to manual add other devices’IP address like NVR, convenience for the maintenance, showing in Figure 4-4. Larson Electronics, LLC Phone: (800) 369-6671 Fax: (903) 498-3364 www.larsonelectronics.com...
  • Page 14: System Setting

    Low-temp alarm is used to alarm when there is lower temp than setting value, this is for lower temp objects. Setting interface is as below Fig 4-5. Here is showing hi-temp alarm as example: Larson Electronics, LLC Phone: (800) 369-6671 Fax: (903) 498-3364 www.larsonelectronics.com...
  • Page 15 (such as the following 37.3℃ ~ 42.0℃), the alarm event is judged to have occurred. The maximum temperature range of high temperature alarm is 30.0℃ ~ 50.0℃, as shown in FIG. 4-6. Setting high temperature alarm FIG. 4-6 Heat level setting Larson Electronics, LLC Phone: (800) 369-6671 Fax: (903) 498-3364 www.larsonelectronics.com 15 of 21...
  • Page 16: Black Body Area Setting

    By dragging the left mouse button to depict the rectangle method, the high temperature interference source from the infrared image shielding. Click the save button on the left side of the window to save. FIG. 4-7 Settings of shielding area Larson Electronics, LLC Phone: (800) 369-6671 Fax: (903) 498-3364 www.larsonelectronics.com 16 of 21...
  • Page 17 4-9. Larson Electronics, LLC Phone: (800) 369-6671 Fax: (903) 498-3364 www.larsonelectronics.com...
  • Page 18: Image Registration

    By this mapping relationship, the accurate coordinates of high temperature target coordinates in infrared image in visible video can be calculated. Larson Electronics, LLC Phone: (800) 369-6671 Fax: (903) 498-3364 www.larsonelectronics.com...
  • Page 19: Image Debugging

    Click the "setup" button in the main interface -- > "system setup" -- > "image debugging", enter the interface of image debugging and setting, and you can adjust the functions of visible light far (near) focus and zoom, as shown in figure 4-11. Figure 4-11 image debugging Settings Larson Electronics, LLC 19 of 21 Phone: (800) 369-6671 Fax: (903) 498-3364...
  • Page 20: Other Settings

    IP address, port and alarm push service switch, and push it regularly. he system language is used for customers to choose to switch familiar languages, so as to operate the equipment better. Larson Electronics, LLC Phone: (800) 369-6671 Fax: (903) 498-3364 www.larsonelectronics.com...
  • Page 21 IND-MD-TM-CS-TH-KT THESE INSTRUCTIONS MAY NOT COVER ALL DETAILS OR VARIATIONS OF THIS PRODUCT FOR YOUR EQUIPMENT OR INSTALLATION REQUIREMENTS. SHOULD FURTHER INFORMATION NOT COVERED BY THESE INSTRUCTIONS BE REQUIRED, PLEASE CONTACT LARSON ELECTRONICS BY EMAIL AT SALES@LARSONELECTRONICS.COM OR BY PHONE AT 1-800-369-6671 FOR FURTHER ASSISTANCE.