Troubleshooting - Telefunken TKVCL3 Instruction Manual

Reversible air con 12 000/13 000 btu in cooling mode
Table of Contents

Advertisement

Available languages

Available languages

2. Water drainage
Your appliance is equipped with the Auto Evaporative System, it will automatically evaporates the
condensation through the air outlet hose. There is no need to empty the drainage tank except for the 3
below conditions:
 Exceptional climate with very high humidity conditions: the water tank fills up faster than the
Auto evaporative system is capable of evacuating the condensation water. The icon "P2" will flash
on the LCD control panel warning you to drain the tank.
 At the end of each seasonal use and in order to extend the life of your appliance. It is
recommended after the water draining operation to fully dry the unit by operating in low fan
mode for 4 hours before putting it in its storage space.
 When the appliance has not been used for a long period.
Water draining operation:
 Unplug your appliance.
 Place a pan under the water plug (Fig. 12 of the product description)
 Unscrew the water plug and let the water drain.
 After the operation, replace the water plug firmly.

TROUBLESHOOTING

Issues
The unit is not working
Bad performance
The unit is too noisy
The remote control is
not working
Possible causes
1: the unit is unplugged
2: No electricity
3: 3 min. timing in progress
4: The selected temperature is closed
to the room temperature
5: The room temperature is below
16°C
1: The air filter is too dirty
2: The air inlet and outlet grid are
clogged by walls or objects
3: Wrong programming
1: The unit is not placed on a stable
and flat surface
2: The air filter is damaged
1: Remote control and the unit is too
far away
2: Batteries are off
Solutions
1: Plug the unit
2: Check for power
3: Wait for 3 min.
4: Select a bigger temperature
gap
5: Stop using the air con
1: Clean the air filter
2: Remove the objects or change
the unit location
3: Switch of the appliance and
restart the setting
1: Place the unit on a stable and
flat surface
2: Change the air filter
1: Get closer to the unit
2: Change the batteries